One-Stop Supply of Conventional & Solar Power Equipment · Power Distribution System Design

50MW 风光储互补电站(2026年第三季度中国供应商价格)

50 MW Wind-Solar-Storage Hybrid Plant Cost Breakdown (Q3 2026 China Supplier Pricing) — itemized bill of materials and FOB pricing for a typical configuration.

Last updated: 2026-09-12 · copper-linked items track the daily LME copper price

Estimated total (FOB): $14,577,056

Bill of materials

ItemSpecificationQtyPrice (USD)
Wind turbine generators (20 MW total)onshore · turbine only $282/kW (FOB reference; tower & BOP quoted per project)1$5,640,000
Wind farm box transformer (22000 kVA)> 1600 kVA — outside catalogue, quoted per project1POA
Wind collector cable (集电电缆) (35 kV MV)radial collector feeders + trenching · quoted per project1POA
Site access roads & crane pads (场内道路) (civil)turbine access roads, hardstands & foundations · quoted per project1POA
Wind turbine erection & crane (吊装) (installation)heavy-lift crane + erection crew · quoted per project1POA
PV modules (54545 × 550 Wp)mono PERC · 30 MWp DC1$3,600,000
String inverters (30 MW AC)three-phase · grid-tied1$1,178,112
PV mounting structure (30 MWp)ground-mount1$1,950,000
Battery energy storage (BESS) (20 MWh)LFP · 90% DoD · 90% RTE1$1,900,000
Power conversion system (PCS) (5000 kW)4 h duration · bidirectional1$293,944
Battery management system (BMS) (cluster)cell monitoring & balancing1$15,000
Step-up power transformer (52.6 MVA)MV/35 kV grid connection · outside distribution catalogue1POA

Single-line diagram

Wind farm20 MW - 30% CFPV plant30 MWp - 4.5 kWh/m2/dBattery (BESS)20 MWh / 4 hStep-up transformer52.6 MVA (POA)Grid35 kV connection
LEGENDBreaker (52)CTCT (current transformer)PTPT (voltage transformer)50/51Protection relay 50/51/51NkWhMeter (kWh)SPD (surge protection)

How it was calculated

成本敏感因素

  • 设备 — 变压器/开关柜/逆变器是最大单项。
  • 储能 — 电池是最大变量。
  • 铜价与运费 — 铜价联动线缆与运费使到岸成本 ±5–10% 波动。

常见问题

如何设计风光储一体化电站容量?
按负荷或外送曲线配光伏与风电,再加储能平抑出力。计算器默认 20 MW 风电 + 30 MW 光伏 + 20 MWh/4 h 储能。容量按逐时资源与负荷匹配,储能填补波动发电与需求的缺口。配置器输出容量、电量与 LCOE。
风电和光伏的互补性是什么?
风电常在夜间和冬季大发,光伏在白天和夏季大发,二者结合可平滑总出力、减少平抑所需的储能。良好的风光互补能把容量因子比单一电源提高 10-20%。配置器分析组合后的 P50/P90 电量曲线。
风光互补电站的典型容量因子是多少?
单独光伏容量因子 15-20%,陆上风电 25-35%,匹配良好的风光互补可达 25-40%。容量因子越高越平滑,LCOE 和电网价值越好。配置器根据风速与辐照输入计算组合容量因子。
储能如何平抑风光互补电站出力?
储能在高发、低价时段充电,在风光不足时放电,把波动出力转成更稳定、可调度的曲线。4 小时电池可覆盖多数日内缺口,计算器默认 20 MWh/4 h。这可提高高峰电价窗口的可交付电量占比。
风光储互补电站适用哪些电网导则?
风机遵循 IEC 61400 与 GB/T 19960,光伏遵循 GB/T 19964,储能遵循 GB/T 36547 与 IEC 62933,互补电站并网遵循 GB/T 19963。配置器引用这些标准并按其电压/频率穿越要求设计。
风光储互补电站能达到多少 LCOE?
资源好的地区大型互补电站 LCOE 达 0.03-0.06 美元/kWh,储能按配比加 0.01-0.03 美元/kWh。默认 20 MW 风电 + 30 MW 光伏 + 20 MWh 典型约 0.04-0.05 美元/kWh。配置器用 WACC、运维和衰减计算全成本 LCOE。

计算你自己的配置

输入你的实际负荷,获得完整 BOM 与 FOB 报价。

Open calculator Request a Quote

相关页面