50MW 光伏并网(2026年第三季度中国供应商价格)
50 MW PV Grid Interconnection Cost Breakdown (Q3 2026 China Supplier Pricing) — itemized bill of materials and FOB pricing for a typical configuration.
Estimated total (FOB): $13,269,655
Bill of materials
| Item | Specification | Qty | Price (USD) |
|---|---|---|---|
| PV Modules (550 Wp Mono PERC) | 550 Wp · 104546 pcs (DC/AC ≈ 1.15) | 104546 | $6,325,033 |
| Central Inverter (2.5 MW string/central) | utility-scale · 50.0 MW AC | 20 | $2,250,000 |
| Ground Mounting Structure (Fixed tilt) | tilt optimized for lat 30° | 1 | $4,000,000 |
| Box-Type Substation (step-up) (0.8/35 kV) | 1600 kVA step-up | 40 | $676,000 |
| HV Switchgear (collector) (KYN61-40.5) | collector switchgear · 7 feeders | 7 | $15,582 |
| Main Transformer (step-up) (SZ11-63MVA/110kV) | 63 MVA 35/110 kV · YNd11 · OLTC | 1 | POA |
| SVG (Static Var Generator) (SVG-15Mvar/110kV) | dynamic reactive compensation | 1 | POA |
| Shunt Reactor (2 Mvar) | absorb collector cable charging | 1 | POA |
| Collector Cable (YJV 26/35 kV) | 95 mm² · radial feeders · 7 feeders | 7 | POA |
| Earthing System (flat bar + rods) | plant grounding grid | 1 | $1,040 |
| SCADA Monitoring (plant-level) | power plant controller + SCADA | 1 | $2,000 |
Single-line diagram
How it was calculated
- ['Voltage level (Module A)', '50.0 MW → 110 kV POI (0.8 kV (inverter) → 35 kV (collector) → 110 kV (step-up) → 110 kV POI)']
- ['Collector (Module B)', '40 arrays × 1600 kVA box sub · 7 feeder(s) · 95 mm² cable']
- ['Main transformer (Module C)', '63 MVA YNd11 · Z=10.5% · ONAN/ONAF']
- ['Reactive power (Module D2)', 'requirement ±12.50 Mvar → SVG 15 Mvar + shunt reactor 2 Mvar']
- ['Short-circuit (Module D4)', 'grid 10.50 kA + PV 0.31 kA (current-source) = 10.81 kA at 110 kV POI']
- ['Generation (Module F)', 'GHI 3.97 kWh/m²/day · PR 0.8 → P50 57,962,000 kWh/yr']
- ['Probability (Module F)', 'P75 56,399,344 · P90 54,994,346 kWh/yr (σ=4% interannual)']
- ['LCOE (Module G)', '$0.0793/kWh full-cost (O&M + WACC + inverter replacement + degradation)']
- ['Economics (Module G)', 'payback 17.1 yr · IRR 2.3% · NPV $-17,380,111 · DSCR 0.65']
成本敏感因素
- 设备 — 变压器/开关柜/逆变器是最大单项。
- 储能 — 电池是最大变量。
- 铜价与运费 — 铜价联动线缆与运费使到岸成本 ±5–10% 波动。
常见问题
光伏电站应以什么电压等级并网?
并网电压随容量而定:约 250 kW 以下用 0.4 kV,250 kW-6 MW 用 10 kV,6 MW 以上用 35 kV 或 110 kV。50 MW 电站通常 110 kV 并网。选型要在变压器损耗与并网成本间权衡,具体接入点由电网公司指定。计算器自动选电压等级与主变容量。
光伏电站需要多少无功补偿?
并网导则(GB/T 19964、IEEE 1547)要求逆变器在 0.95 超前至 0.95 滞后功率因数范围内运行,且故障时通常要提供无功支撑。大型电站一般加装占容量 10-30% 的集中式 SVG/SVC。50 MW 电站常配 10-15 Mvar 动态补偿以满足电压支撑要求。
光伏逆变器会贡献多少短路电流?
跟网型光伏逆变器的短路电流贡献约为额定电流的 1.0-1.2 倍、持续几个周波,远小于同步机的 5-7 倍。50 MW 电站贡献约 60-70 MVA。校核断路器与变压器故障容量时需计入,计算器已把光伏短路贡献纳入并网计算。
光伏电站的集电线路典型电压是多少?
大型光伏电站通过 800 V 直流汇集到集中式或组串式逆变器,再经 0.8 kV 升压至 10 kV 或 35 kV 集电线路。组串式逆变器(≤250 kW)进 10 kV 集电,集中式(500 kW-3 MW)进 35 kV。集电线路典型 5-20 km,压降控制在 2% 以内。
光伏电站主变压器如何选型?
主变容量 = 逆变器交流容量 ÷ 功率因数,留 5-10% 裕量后取标准容量(IEC 60076)。50 MWac、0.95 功率因数约需 55 MVA,取 63 MVA。光伏主变多为油浸 ONAN、35/110 kV,空载损耗按 GB/T 6451 能效等级限制。
并网需要做哪些电网导则符合性校核?
按 GB/T 19963/19964 与 IEEE 1547 的关键校核包括:高低电压穿越、频率穿越(典型 47.5-51.5 Hz)、功率因数能力、爬坡率限制和防孤岛。计算器校核电压等级匹配、主变选型、无功补偿与故障贡献,并对超出典型导则包络的参数给出提示。