One-Stop Supply of Conventional & Solar Power Equipment · Power Distribution System Design

50MW 光伏并网(2026年第三季度中国供应商价格)

50 MW PV Grid Interconnection Cost Breakdown (Q3 2026 China Supplier Pricing) — itemized bill of materials and FOB pricing for a typical configuration.

Last updated: 2026-09-12 · copper-linked items track the daily LME copper price

Estimated total (FOB): $13,269,655

Bill of materials

ItemSpecificationQtyPrice (USD)
PV Modules (550 Wp Mono PERC)550 Wp · 104546 pcs (DC/AC ≈ 1.15)104546$6,325,033
Central Inverter (2.5 MW string/central)utility-scale · 50.0 MW AC20$2,250,000
Ground Mounting Structure (Fixed tilt)tilt optimized for lat 30°1$4,000,000
Box-Type Substation (step-up) (0.8/35 kV)1600 kVA step-up40$676,000
HV Switchgear (collector) (KYN61-40.5)collector switchgear · 7 feeders7$15,582
Main Transformer (step-up) (SZ11-63MVA/110kV)63 MVA 35/110 kV · YNd11 · OLTC1POA
SVG (Static Var Generator) (SVG-15Mvar/110kV)dynamic reactive compensation1POA
Shunt Reactor (2 Mvar)absorb collector cable charging1POA
Collector Cable (YJV 26/35 kV)95 mm² · radial feeders · 7 feeders7POA
Earthing System (flat bar + rods)plant grounding grid1$1,040
SCADA Monitoring (plant-level)power plant controller + SCADA1$2,000

Single-line diagram

POI (Point of Interconnection)Utility GridCTCT110 kV POI breaker50/5151NkWhmeteringMain transformer63 MVA 35/110 kVSZ11 - YNd11OLTC - ONAN/ONAFSVG 15 MvarShunt reactor 2 Mvar35 kV collector busPTPTSPDCollector feeder 1YJV 35 kV (radial)Collector feeder 2YJV 35 kV (radial)Collector feeder 3YJV 35 kV (radial)Collector feeder 4YJV 35 kV (radial)Collector feeder 5YJV 35 kV (radial)Collector feeder 6YJV 35 kV (radial)Collector feeder 7YJV 35 kV (radial)Box sub1600 kVABox sub1600 kVABox sub1600 kVABox sub1600 kVABox sub1600 kVABox sub1600 kVA + 34 more box substations (40 arrays total)PV array + string inverter0.8 kV DC/AC
LEGENDBreaker (52)CTCT (current transformer)PTPT (voltage transformer)50/51Protection relay 50/51/51NkWhMeter (kWh)SPD (surge protection)

How it was calculated

成本敏感因素

  • 设备 — 变压器/开关柜/逆变器是最大单项。
  • 储能 — 电池是最大变量。
  • 铜价与运费 — 铜价联动线缆与运费使到岸成本 ±5–10% 波动。

常见问题

光伏电站应以什么电压等级并网?
并网电压随容量而定:约 250 kW 以下用 0.4 kV,250 kW-6 MW 用 10 kV,6 MW 以上用 35 kV 或 110 kV。50 MW 电站通常 110 kV 并网。选型要在变压器损耗与并网成本间权衡,具体接入点由电网公司指定。计算器自动选电压等级与主变容量。
光伏电站需要多少无功补偿?
并网导则(GB/T 19964、IEEE 1547)要求逆变器在 0.95 超前至 0.95 滞后功率因数范围内运行,且故障时通常要提供无功支撑。大型电站一般加装占容量 10-30% 的集中式 SVG/SVC。50 MW 电站常配 10-15 Mvar 动态补偿以满足电压支撑要求。
光伏逆变器会贡献多少短路电流?
跟网型光伏逆变器的短路电流贡献约为额定电流的 1.0-1.2 倍、持续几个周波,远小于同步机的 5-7 倍。50 MW 电站贡献约 60-70 MVA。校核断路器与变压器故障容量时需计入,计算器已把光伏短路贡献纳入并网计算。
光伏电站的集电线路典型电压是多少?
大型光伏电站通过 800 V 直流汇集到集中式或组串式逆变器,再经 0.8 kV 升压至 10 kV 或 35 kV 集电线路。组串式逆变器(≤250 kW)进 10 kV 集电,集中式(500 kW-3 MW)进 35 kV。集电线路典型 5-20 km,压降控制在 2% 以内。
光伏电站主变压器如何选型?
主变容量 = 逆变器交流容量 ÷ 功率因数,留 5-10% 裕量后取标准容量(IEC 60076)。50 MWac、0.95 功率因数约需 55 MVA,取 63 MVA。光伏主变多为油浸 ONAN、35/110 kV,空载损耗按 GB/T 6451 能效等级限制。
并网需要做哪些电网导则符合性校核?
按 GB/T 19963/19964 与 IEEE 1547 的关键校核包括:高低电压穿越、频率穿越(典型 47.5-51.5 Hz)、功率因数能力、爬坡率限制和防孤岛。计算器校核电压等级匹配、主变选型、无功补偿与故障贡献,并对超出典型导则包络的参数给出提示。

计算你自己的配置

输入你的实际负荷,获得完整 BOM 与 FOB 报价。

Open calculator Request a Quote