Transformator QDTB®

Konverter Satuan Listrik

Konversi cepat satuan yang digunakan insinyur listrik setiap hari — daya, ukuran kawat, suhu, panjang, torsi dan frekuensi — dalam satu alat referensi.

Mulai Menghitung

Hasil

Masukkan beban Anda → dapatkan desain lengkap & BOM dalam hitungan detik

Contoh keluaran
Power conversion
100
Power
Conversion results
QuantityConverted value
Kilowatt100.000 kW
Megawatt0.100000 MW
Watt100000 W
Apparent power (at PF 0.8)125.000 kVA
Horsepower (mechanical)134.102 hp

Referensi cepat untuk insinyur, teknisi dan siswa yang mengonversi antara satuan listrik dan mekanik umum.

Gunakan kalkulator

Contoh perhitungan

Contoh referensi yang telah dihitung sebelumnya (dapat dirayapi — tidak memerlukan JavaScript). Masukkan parameter Anda sendiri di atas untuk hasil langsung.

Contoh 1 — 100 kW pada PF 0,8

Power conversion
100
Power
Conversion results
QuantityConverted value
Kilowatt100.000 kW
Megawatt0.100000 MW
Watt100000 W
Apparent power (at PF 0.8)125.000 kVA
Horsepower (mechanical)134.102 hp

Contoh 2 — ukuran kawat AWG 10

Wire size (AWG 10)
10
Wire size
Conversion results
QuantityConverted value
Cross-sectional area5.261 mm²
Conductor diameter2.588 mm
Approx. ampacity (copper, ≈3.5 A/mm²)18 A (typical, derate per installation)

Cara perhitungannya

  • · Daya: kW ÷ PF = kVA; 1 hp = 0,7457 kW.
  • · Kawat: A(mm²) = 0,012668 × 92^((36−AWG)/19,5); d(mm) = 0,127 × 92^((36−AWG)/39).
  • · Suhu: °F = °C × 9/5 + 32; K = °C + 273,15.
  • · Torsi: 1 N·m = 0,7376 lb·ft = 0,10197 kgf·m.
  • · Kecepatan sinkron: rpm = 120 × f ÷ kutub.

Standar yang dirujuk

StandardScope
SI / IEC 60027Sistem satuan internasional dan simbol huruf untuk teknologi listrik
ASTM B258Diameter nominal standar dan luas penampang ukuran konduktor AWG

Pertanyaan yang sering diajukan

How do I convert kVA to kW?

kW = kVA x Power Factor. A 500 kVA Transformer at 0.8 pf delivers 400 kW. The reverse is kVA = kW / pf. Without knowing the power factor you cannot convert exactly — the calculator applies your pf to convert apparent and real power.

How do I convert AWG to mm2?

AWG and mm2 are both conductor cross-section measures. Common equivalences: 10 AWG = 5.26 mm2, 8 AWG = 8.37 mm2, 6 AWG = 13.3 mm2, 4 AWG = 21.2 mm2, 2 AWG = 33.6 mm2, and 0 AWG = 53.5 mm2. The calculator converts both ways for cable sizing.

What temperature scale do transformer ratings use?

Transformer Temperature Rise is specified in Kelvin or degrees Celsius (identical step size); ambient reference is usually 40 deg C, with Class F insulation rated 155 deg C and Class H 180 deg C. The calculator converts Celsius, Fahrenheit and Kelvin for thermal checks.

How do I convert torque units for motor specifications?

Motor torque units: Nm, kgfm, lb-ft. 1 Nm = 0.10197 kgfm = 0.7376 lb-ft. A 1000 Nm motor is about 102 kgfm or 738 lb-ft. The calculator converts torque and other common electrical units (power, length, frequency) in one place.

What is the difference between kW, kVA and kvar?

kW is real (useful) power, kvar is reactive power, and kVA is apparent power (their vector sum): kVA^2 = kW^2 + kvar^2. Power factor = kW/kVA. A 100 kW load at 0.8 pf draws 125 kVA and 75 kvar. The calculator converts among them.

Sematkan kalkulator ini

Tambahkan kalkulator ini ke situs web Anda sendiri secara gratis. Iframe menyesuaikan dengan lebar apa pun dan berjalan sepenuhnya di browser pengunjung Anda.

Alat terkait

Hasil adalah perkiraan teknik untuk desain awal dan referensi saja. Selalu verifikasi dengan standar yang berlaku, pelat nama peralatan, dan insinyur berlisensi sebelum pengadaan atau pemasangan.

Send my complete design report

Get the full bill of materials, single-line diagram, calculation steps and FOB pricing as a PDF — free, no sign-up.

💬 Chat on WhatsApp