Konverter Satuan Listrik
Konversi cepat satuan yang digunakan insinyur listrik setiap hari — daya, ukuran kawat, suhu, panjang, torsi dan frekuensi — dalam satu alat referensi.
Hasil
Masukkan beban Anda → dapatkan desain lengkap & BOM dalam hitungan detik
Contoh keluaran| Quantity | Converted value |
|---|---|
| Kilowatt | 100.000 kW |
| Megawatt | 0.100000 MW |
| Watt | 100000 W |
| Apparent power (at PF 0.8) | 125.000 kVA |
| Horsepower (mechanical) | 134.102 hp |
Referensi cepat untuk insinyur, teknisi dan siswa yang mengonversi antara satuan listrik dan mekanik umum.
Gunakan kalkulator
Contoh perhitungan
Contoh referensi yang telah dihitung sebelumnya (dapat dirayapi — tidak memerlukan JavaScript). Masukkan parameter Anda sendiri di atas untuk hasil langsung.
Contoh 1 — 100 kW pada PF 0,8
| Quantity | Converted value |
|---|---|
| Kilowatt | 100.000 kW |
| Megawatt | 0.100000 MW |
| Watt | 100000 W |
| Apparent power (at PF 0.8) | 125.000 kVA |
| Horsepower (mechanical) | 134.102 hp |
Contoh 2 — ukuran kawat AWG 10
| Quantity | Converted value |
|---|---|
| Cross-sectional area | 5.261 mm² |
| Conductor diameter | 2.588 mm |
| Approx. ampacity (copper, ≈3.5 A/mm²) | 18 A (typical, derate per installation) |
Cara perhitungannya
- · Daya: kW ÷ PF = kVA; 1 hp = 0,7457 kW.
- · Kawat: A(mm²) = 0,012668 × 92^((36−AWG)/19,5); d(mm) = 0,127 × 92^((36−AWG)/39).
- · Suhu: °F = °C × 9/5 + 32; K = °C + 273,15.
- · Torsi: 1 N·m = 0,7376 lb·ft = 0,10197 kgf·m.
- · Kecepatan sinkron: rpm = 120 × f ÷ kutub.
Standar yang dirujuk
| Standard | Scope |
|---|---|
| SI / IEC 60027 | Sistem satuan internasional dan simbol huruf untuk teknologi listrik |
| ASTM B258 | Diameter nominal standar dan luas penampang ukuran konduktor AWG |
Pertanyaan yang sering diajukan
How do I convert kVA to kW?
kW = kVA x Power Factor. A 500 kVA Transformer at 0.8 pf delivers 400 kW. The reverse is kVA = kW / pf. Without knowing the power factor you cannot convert exactly — the calculator applies your pf to convert apparent and real power.
How do I convert AWG to mm2?
AWG and mm2 are both conductor cross-section measures. Common equivalences: 10 AWG = 5.26 mm2, 8 AWG = 8.37 mm2, 6 AWG = 13.3 mm2, 4 AWG = 21.2 mm2, 2 AWG = 33.6 mm2, and 0 AWG = 53.5 mm2. The calculator converts both ways for cable sizing.
What temperature scale do transformer ratings use?
Transformer Temperature Rise is specified in Kelvin or degrees Celsius (identical step size); ambient reference is usually 40 deg C, with Class F insulation rated 155 deg C and Class H 180 deg C. The calculator converts Celsius, Fahrenheit and Kelvin for thermal checks.
How do I convert torque units for motor specifications?
Motor torque units: Nm, kgfm, lb-ft. 1 Nm = 0.10197 kgfm = 0.7376 lb-ft. A 1000 Nm motor is about 102 kgfm or 738 lb-ft. The calculator converts torque and other common electrical units (power, length, frequency) in one place.
What is the difference between kW, kVA and kvar?
kW is real (useful) power, kvar is reactive power, and kVA is apparent power (their vector sum): kVA^2 = kW^2 + kvar^2. Power factor = kW/kVA. A 100 kW load at 0.8 pf draws 125 kVA and 75 kvar. The calculator converts among them.
Sematkan kalkulator ini
Tambahkan kalkulator ini ke situs web Anda sendiri secara gratis. Iframe menyesuaikan dengan lebar apa pun dan berjalan sepenuhnya di browser pengunjung Anda.
Alat terkait
Hasil adalah perkiraan teknik untuk desain awal dan referensi saja. Selalu verifikasi dengan standar yang berlaku, pelat nama peralatan, dan insinyur berlisensi sebelum pengadaan atau pemasangan.
Send my complete design report
Get the full bill of materials, single-line diagram, calculation steps and FOB pricing as a PDF — free, no sign-up.
Your data stays private. No spam — only a reply to your enquiry.