S-2000/600/347

Other Series2000 kVA • 0.6/0.347 kV

Product Image & Parameters

2000kVAOther

S-2000/600/347

Other Series

Capacity
2000kVA
HV Voltage
0.6kV
LV Voltage
0.347kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: S-2000/600/347 | Type: Dry-Type Transformer | Capacity: 2000 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N300mm360mm

SIDE VIEW

Ventilation195mm

TOP VIEW

1U1V1W2U2V2W2N300mm195mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDelta-Wye (IEEE Std)

SPECIFICATIONS

1. Model:S-2000/600/347
2. Type:Dry-Type Transformer
3. Capacity:2000 kVA
4. Frequency:60 Hz
5. HV Voltage:0.6 kV
6. LV Voltage:0.347 kV
7. HV Current:1924.5A
8. LV Current:3327.67A
9. Vector Group:Delta-Wye (IEEE Std)
10. Impedance:6%
11. Insulation Level:A (105°C)
12. Temperature Rise:65K
13. No-Load Loss:22880W
14. Load Loss:57200W
15. No-Load Current:0.3%
16. Cooling Method:ONAN
17. Tap Changer:±5×2.5% 多档
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:2000×1300×2400mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

2000kVA, 3-phase oil-immersed transformer, 60Hz, primary 600V (HV 600V), secondary 347V (LV 347V), Export, insulation A, impedance 6%

Related Keywords

S-2000/600/347 oil immersed power transformer2000kVA oil type distribution transformer0.6kV distribution network transformerS series general purpose oil filled distribution transformer

S-2000/600/347 FAQ

What are the main application scenarios for S-2000/600/347?
The S-2000/600/347 (Other series oil-immersed transformers) with rated capacity of 2000 kVA, HV side 0.6 kV, LV side 0.347 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of S-2000/600/347?
Key specs: Capacity 2000 kVA, HV 0.6 kV, LV 0.347 kV, Frequency 60 Hz, Impedance 6%, Vector Group Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.
Can S-2000/600/347 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in S-2000/600/347?

Contact us for pricing, technical support, or custom requirements.