SZ11-M-100/0.48/0.208

Other Series100 kVA • 0.48/0.208 kV

Product Image & Parameters

100kVAOther

SZ11-M-100/0.48/0.208

Other Series

Capacity
100kVA
HV Voltage
0.48kV
LV Voltage
0.208kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: SZ11-M-100/0.48/0.208 | Type: Dry-Type Transformer | Capacity: 100 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N135mm180mm

SIDE VIEW

Ventilation105mm

TOP VIEW

1U1V1W2U2V2W2N135mm105mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDelta-Wye (IEEE Std)

SPECIFICATIONS

1. Model:SZ11-M-100/0.48/0.208
2. Type:Dry-Type Transformer
3. Capacity:100 kVA
4. Frequency:60 Hz
5. HV Voltage:0.48 kV
6. LV Voltage:0.208 kV
7. HV Current:120.28A
8. LV Current:277.57A
9. Vector Group:Delta-Wye (IEEE Std)
10. Impedance:4%
11. Insulation Level:A (105°C)
12. Temperature Rise:65K
13. No-Load Loss:2850W
14. Load Loss:7125W
15. No-Load Current:0.6%
16. Cooling Method:ONAN
17. Tap Changer:±5% 单档
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:900×700×1200mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

100kVA, 3-phase oil-immersed transformer, 60Hz, primary 480V (HV 480V), secondary 208V (LV 208V), S11, insulation A, impedance 4%

Related Keywords

SZ11-M-100/0.48/0.208 oil immersed power transformer100kVA oil type distribution transformer0.48kV distribution network transformerSZ11 on-load tap changing oil transformer for voltage regulation

SZ11-M-100/0.48/0.208 FAQ

What are the main application scenarios for SZ11-M-100/0.48/0.208?
The SZ11-M-100/0.48/0.208 (Other series oil-immersed transformers) with rated capacity of 100 kVA, HV side 0.48 kV, LV side 0.208 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of SZ11-M-100/0.48/0.208?
Key specs: Capacity 100 kVA, HV 0.48 kV, LV 0.208 kV, Frequency 60 Hz, Impedance 4%, Vector Group Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.
Can SZ11-M-100/0.48/0.208 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in SZ11-M-100/0.48/0.208?

Contact us for pricing, technical support, or custom requirements.