Capacity
160kVA
HV Voltage
10kV
LV Voltage
0.48kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: SZ11-M-160/10/0.48 | Type: Dry-Type Transformer | Capacity: 160 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N150mm210mm

SIDE VIEW

Ventilation120mm

TOP VIEW

1U1V1W2U2V2W2N150mm120mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDelta-Wye (IEEE Std)

SPECIFICATIONS

1. Model:SZ11-M-160/10/0.48
2. Type:Dry-Type Transformer
3. Capacity:160 kVA
4. Frequency:60 Hz
5. HV Voltage:10 kV
6. LV Voltage:0.48 kV
7. HV Current:9.24A
8. LV Current:192.45A
9. Vector Group:Delta-Wye (IEEE Std)
10. Impedance:4.5%
11. Insulation Level:A (105°C)
12. Temperature Rise:65K
13. No-Load Loss:4050W
14. Load Loss:10125W
15. No-Load Current:0.5%
16. Cooling Method:ONAN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:1000×800×1400mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

160kVA, 3-phase oil-immersed transformer, 60Hz, primary 10kV (HV 10kV), secondary 480V (LV 480V), S11, insulation A, impedance 4.5%

Related Keywords

SZ11-M-160/10/0.48 oil immersed power transformer160kVA oil type distribution transformer10kV distribution network transformerSZ11 on-load tap changing oil transformer for voltage regulation

SZ11-M-160/10/0.48 FAQ

What are the main application scenarios for SZ11-M-160/10/0.48?
The SZ11-M-160/10/0.48 (Other series oil-immersed transformers) with rated capacity of 160 kVA, HV side 10 kV, LV side 0.48 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of SZ11-M-160/10/0.48?
Key specs: Capacity 160 kVA, HV 10 kV, LV 0.48 kV, Frequency 60 Hz, Impedance 4.5%, Vector Group Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.
Can SZ11-M-160/10/0.48 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in SZ11-M-160/10/0.48?

Contact us for pricing, technical support, or custom requirements.