SZ11-M-63/35/0.4

Other Series63 kVA • 35/0.4 kV

Product Image & Parameters

63kVAOther

SZ11-M-63/35/0.4

Other Series

Capacity
63kVA
HV Voltage
35kV
LV Voltage
0.4kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: SZ11-M-63/35/0.4 | Type: Dry-Type Transformer | Capacity: 63 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N135mm180mm

SIDE VIEW

Ventilation105mm

TOP VIEW

1U1V1W2U2V2W2N135mm105mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDyn11 (IEC)

SPECIFICATIONS

1. Model:SZ11-M-63/35/0.4
2. Type:Dry-Type Transformer
3. Capacity:63 kVA
4. Frequency:50 Hz
5. HV Voltage:35 kV
6. LV Voltage:0.4 kV
7. HV Current:1.04A
8. LV Current:90.93A
9. Vector Group:Dyn11 (IEC)
10. Impedance:4%
11. Insulation Level:A (105°C)
12. Temperature Rise:65K
13. No-Load Loss:2010W
14. Load Loss:5025W
15. No-Load Current:0.7%
16. Cooling Method:ONAN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEC 60076
19. Dimensions:900×700×1200mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

63kVA, 3-phase oil-immersed transformer, 50Hz, primary 35kV (HV 35kV), secondary 400V (LV 400V), S11, insulation A, impedance 4%

Related Keywords

SZ11-M-63/35/0.4 oil immersed power transformer63kVA oil type distribution transformer35kV distribution network transformerSZ11 on-load tap changing oil transformer for voltage regulation

SZ11-M-63/35/0.4 FAQ

What are the main application scenarios for SZ11-M-63/35/0.4?
The SZ11-M-63/35/0.4 (Other series oil-immersed transformers) with rated capacity of 63 kVA, HV side 35 kV, LV side 0.4 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of SZ11-M-63/35/0.4?
Key specs: Capacity 63 kVA, HV 35 kV, LV 0.4 kV, Frequency 50 Hz, Impedance 4%, Vector Group Dyn11 (IEC), Cooling ONAN, Standard IEC 60076.
Can SZ11-M-63/35/0.4 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in SZ11-M-63/35/0.4?

Contact us for pricing, technical support, or custom requirements.