SFFZ-1000/0.66/0.38

Other Series1000 kVA • 0.66/0.38 kV

Product Image & Parameters

1000kVAOther

SFFZ-1000/0.66/0.38

Other Series

Capacity
1000kVA
HV Voltage
0.66kV
LV Voltage
0.38kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: SFFZ-1000/0.66/0.38 | Type: Dry-Type Transformer | Capacity: 1000 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N240mm300mm

SIDE VIEW

Ventilation165mm

TOP VIEW

1U1V1W2U2V2W2N240mm165mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDyn11 (IEC)

SPECIFICATIONS

1. Model:SFFZ-1000/0.66/0.38
2. Type:Dry-Type Transformer
3. Capacity:1000 kVA
4. Frequency:50 Hz
5. HV Voltage:0.66 kV
6. LV Voltage:0.38 kV
7. HV Current:874.77A
8. LV Current:1519.34A
9. Vector Group:Dyn11 (IEC)
10. Impedance:6%
11. Insulation Level:H (180°C)
12. Temperature Rise:65K
13. No-Load Loss:20669W
14. Load Loss:51672W
15. No-Load Current:0.8%
16. Cooling Method:AN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEC 60076
19. Dimensions:1600×1100×2000mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

1000kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 660V (HV 660V), secondary 380V (LV 380V), Standard, insulation H, impedance 6%

Related Keywords

SFFZ-1000/0.66/0.38 isolation control transformer1000kVA control transformerprimary 0.66kV secondary 0.38kVSFFZ split winding transformer for power plant auxiliary system

SFFZ-1000/0.66/0.38 FAQ

What are the main application scenarios for SFFZ-1000/0.66/0.38?
The SFFZ-1000/0.66/0.38 (Other series special/isolation/control transformers) with rated capacity of 1000 kVA, HV side 0.66 kV, LV side 0.38 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of SFFZ-1000/0.66/0.38?
Key specs: Capacity 1000 kVA, HV 0.66 kV, LV 0.38 kV, Frequency 50 Hz, Impedance 6%, Vector Group Dyn11 (IEC), Cooling AN, Standard IEC 60076.
Can SFFZ-1000/0.66/0.38 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.