SC(B)H15-50/6

SC(B)H15干式非晶系列 Series50 kVA • 6/0.4 kV

Product Image & Parameters

50kVASC(B)H15干式非晶系列

SC(B)H15-50/6

SC(B)H15干式非晶系列 Series

Capacity
50kVA
HV Voltage
6kV
LV Voltage
0.4kV
Efficiency
4Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: SC(B)H15-50/6 | Type: Amorphous Alloy Transformer | Capacity: 50 kVA

FRONT VIEW

Amorphous Core1U1V1W2U2V2W2N120mm150mm

SIDE VIEW

Oil Level90mm

TOP VIEW

1U1V1W2U2V2W2N120mm90mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDyn11

SPECIFICATIONS

1. Model:SC(B)H15-50/6
2. Type:Amorphous Alloy Transformer
3. Capacity:50 kVA
4. Frequency:50 Hz
5. HV Voltage:6 kV
6. LV Voltage:0.4 kV
7. HV Current:4.81A
8. LV Current:72.17A
9. Vector Group:Dyn11
10. Impedance:4%
11. Insulation Level:F(155°C)
12. Temperature Rise:80K
13. No-Load Loss:90W
14. Load Loss:225W
15. No-Load Current:1.4%
16. Cooling Method:AN/AF
17. Tap Changer:±2×2.5%或±5%
18. Standard:GB/T1094.11, IEC 60076-11
19. Dimensions:800×600×1000mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

50kVA amorphous alloy cast resin dry-type transformer, 6/0.4kV, Yyn0

SC(B)H15 50kVA amorphous alloy dry-type transformer. No-load loss 75% lower than standard dry-type. Oil-free, fire-retardant, maintenance-free. For indoor installation in buildings, hospitals, airports.

Related Keywords

SC(B)H15-50/6 amorphous alloy transformer50kVA amorphous distribution transformerSCBH15 dry type amorphous alloy transformer fire-proof for commercial buildingcast resin amorphous core transformer for green building energy saving

SC(B)H15-50/6 FAQ

What are the main application scenarios for SC(B)H15-50/6?
The SC(B)H15-50/6 (SC(B)H15干式非晶系列 series amorphous alloy transformers) with rated capacity of 50 kVA, HV side 6 kV, LV side 0.4 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of SC(B)H15-50/6?
Key specs: Capacity 50 kVA, HV 6 kV, LV 0.4 kV, Frequency 50 Hz, Impedance 4%, Vector Group Dyn11, Cooling AN/AF, Standard GB/T1094.11, IEC 60076-11.
Can SC(B)H15-50/6 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in SC(B)H15-50/6?