S-2000/2/480
S Serie • 2000kVA • 2.4/0.48 kV
S-2000/2/480 is a 2000 kVA, 2.4/0.48 kV transformadore sumergidos en aceite manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEEE C57 / ANSI C84.1, vector group Delta-Wye (IEEE Std), short-circuit impedance 6%, approximate weight 4572.5 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.
Technical Specifications
| Model | S-2000/2/480 |
|---|---|
| Rated Capacity | 2000kVA |
| HV Voltage | 2.4 kV |
| LV Voltage | 0.48 kV |
| Frequency | 60 Hz |
| Vector Group | Delta-Wye (IEEE Std) |
| Short-circuit Impedance | 6% |
| Cooling | ONAN |
| Insulation | A (105°C) |
| Temperature Rise | 65 K |
| No-load Loss | 2816 W |
| Load Loss | 17357 W |
| Efficiency | Export standard |
| Weight | 4572.5 kg |
| Dimensions | 1999×1368×1538 mm |
| Applied Standard | IEEE C57 / ANSI C84.1 |
Puntos de operación típicos
Calculado a partir de las pérdidas de placa de este modelo (P₀ 2816 W, P_k 17357 W), u_k 6%, con factor de potencia 0.9.
| Carga | Salida (kW) | Pérdida en vacío (kW) | Pérdida de carga (kW) | Pérdida total (kW) | Rendimiento (%) | Regulación de tensión (%) |
|---|---|---|---|---|---|---|
| 50% | 900.0 | 2.816 | 4.339 | 7.155 | 99.21 | 1.72 |
| 75% | 1350.0 | 2.816 | 9.763 | 12.579 | 99.08 | 2.60 |
| 100% | 1800.0 | 2.816 | 17.357 | 20.173 | 98.89 | 3.49 |
| 125% | 2250.0 | 2.816 | 27.120 | 29.936 | 98.69 | 4.40 |
Rendimiento máximo en torno a 806 kVA (40.3% de la potencia nominal) — β* = √(P₀ / P_k).
Imagen y parámetros del producto

Las imágenes son sólo para fines ilustrativos.
S-2000/2/480
S Serie
TECHNICAL DRAWING
Modelo: S-2000/2/480 | Tipo: Transformador sumergido en aceite | Capacidad: 2000 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
Especificaciones técnicas
LEGEND:
Descripción del Producto
Transformador trifásico sumergido en aceite de 2000 kVA, 60 Hz, primario 2,4 kV (HV 2,4 kV), secundario 480 V (LV 480 V), exportación, aislamiento A, impedancia 6 %
Palabras clave relacionadas
Calculadora de cotización y selección instantánea
Seleccione sus especificaciones para obtener un precio estimado al instante.
Más opciones(6)
Certificación
Los valores a continuación se calculan a partir de lo que seleccionó arriba. Todo lo que aún no se puede calcular se muestra como un guion largo — nunca como cero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Aún se requiere para completar el cálculo: capacidad nominal S,tensión de impedancia uₖ,corriente admisible de corta duración o de cresta.
Los valores por modelo (P0 / Pk / uₖ declarados por fábrica, pérdidas, ruido, elevación de temperatura, dimensiones, peso) no están en la biblioteca de productos: esas filas permanecen con un guion largo hasta que se suministre la hoja de parámetros de fábrica. Un guion largo significa que el valor no está disponible — nunca se representa como cero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)
Los precios de referencia son sólo para estimación y no constituyen una oferta formal.
3 · Solicita esta cotización
Le responderemos con la última cotización al instante.
S-2000/2/480 - Preguntas frecuentes
Q¿Cuáles son las principales aplicaciones de S-2000/2/480?
S-2000/2/480 (serie S, Transformadores sumergidos en aceite) se usa ampliamente en Distribución de energía industrial, edificios comerciales y sistemas de energía de servicios públicos.. Se puede configurar de forma flexible según los requisitos reales del proyecto.
Q¿Cuáles son las principales especificaciones técnicas de S-2000/2/480?
Especificaciones clave: Capacidad: 2000kVA, HV 2.4 kV, LV 0.48 kV, Frecuencia 60 Hz, Impedancia 6%, Conexión Delta-Wye (IEEE Std), Enfriamiento ONAN, Estándar IEEE C57 / ANSI C84.1.
Q¿Se puede pedir S-2000/2/480 a medida?
Sí. QDTB® proporciona servicios integrales de personalización OEM/ODM. Se pueden ajustar parámetros como capacidad, relación de voltaje, método de enfriamiento, grupo de conexión y clase de protección. Más de 25 años de experiencia en fabricación garantizan una calidad constante.
Q¿Cómo conseguir presupuesto y documentación técnica?
Póngase en contacto a través del botón "Enviar consulta" a continuación, o comuníquese con ventas en Alice@qdtb-transformer.com / +86 13698683193. Le proporcionamos cotizaciones detalladas y documentación técnica al instante.
Productos relacionados en la Serie S
¿Interesado en S-2000/2/480?
Contáctenos para conocer precios, soporte técnico o requisitos personalizados.