S11-R-M-50/10/0.48
S11 Serie • 50kVA • 10/0.48 kV
S11-R-M-50/10/0.48 is a 50 kVA, 10/0.48 kV transformadore sumergidos en aceite manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEEE C57 / ANSI C84.1, vector group Delta-Wye (IEEE Std), short-circuit impedance 4%, approximate weight 430 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.
Technical Specifications
| Model | S11-R-M-50/10/0.48 |
|---|---|
| Rated Capacity | 50kVA |
| HV Voltage | 10 kV |
| LV Voltage | 0.48 kV |
| Frequency | 60 Hz |
| Vector Group | Delta-Wye (IEEE Std) |
| Short-circuit Impedance | 4% |
| Cooling | ONAN |
| Insulation | A (105°C) |
| Temperature Rise | 65 K |
| No-load Loss | 130 W |
| Load Loss | 870 W |
| Efficiency | 1Class 1 |
| Weight | 430 kg |
| Dimensions | 899×499×692 mm |
| Applied Standard | IEEE C57 / ANSI C84.1 |
Puntos de operación típicos
Calculado a partir de las pérdidas de placa de este modelo (P₀ 130 W, P_k 870 W), u_k 4%, con factor de potencia 0.9.
| Carga | Salida (kW) | Pérdida en vacío (kW) | Pérdida de carga (kW) | Pérdida total (kW) | Rendimiento (%) | Regulación de tensión (%) |
|---|---|---|---|---|---|---|
| 50% | 22.5 | 0.130 | 0.217 | 0.347 | 98.48 | 1.58 |
| 75% | 33.8 | 0.130 | 0.489 | 0.619 | 98.20 | 2.37 |
| 100% | 45.0 | 0.130 | 0.870 | 1.000 | 97.83 | 3.17 |
| 125% | 56.3 | 0.130 | 1.359 | 1.489 | 97.42 | 3.97 |
Rendimiento máximo en torno a 19 kVA (38.7% de la potencia nominal) — β* = √(P₀ / P_k).
Imagen y parámetros del producto

Las imágenes son sólo para fines ilustrativos.
S11-R-M-50/10/0.48
S11 Serie
TECHNICAL DRAWING
Modelo: S11-R-M-50/10/0.48 | Tipo: Transformador sumergido en aceite | Capacidad: 50 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
Especificaciones técnicas
LEGEND:
Descripción del Producto
Transformador trifásico sumergido en aceite de 50 kVA, 60 Hz, primario 10 kV (HV 10 kV), secundario 480 V (LV 480 V), S11, aislamiento A, impedancia 4 %
Palabras clave relacionadas
Calculadora de cotización y selección instantánea
Seleccione sus especificaciones para obtener un precio estimado al instante.
Más opciones(6)
Certificación
Los valores a continuación se calculan a partir de lo que seleccionó arriba. Todo lo que aún no se puede calcular se muestra como un guion largo — nunca como cero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Aún se requiere para completar el cálculo: capacidad nominal S,tensión de impedancia uₖ,corriente admisible de corta duración o de cresta.
Los valores por modelo (P0 / Pk / uₖ declarados por fábrica, pérdidas, ruido, elevación de temperatura, dimensiones, peso) no están en la biblioteca de productos: esas filas permanecen con un guion largo hasta que se suministre la hoja de parámetros de fábrica. Un guion largo significa que el valor no está disponible — nunca se representa como cero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)
Los precios de referencia son sólo para estimación y no constituyen una oferta formal.
3 · Solicita esta cotización
Le responderemos con la última cotización al instante.
S11-R-M-50/10/0.48 - Preguntas frecuentes
Q¿Cuáles son las principales aplicaciones de S11-R-M-50/10/0.48?
S11-R-M-50/10/0.48 (serie S11, Transformadores sumergidos en aceite) se usa ampliamente en Distribución de energía industrial, edificios comerciales y sistemas de energía de servicios públicos.. Se puede configurar de forma flexible según los requisitos reales del proyecto.
Q¿Cuáles son las principales especificaciones técnicas de S11-R-M-50/10/0.48?
Especificaciones clave: Capacidad: 50kVA, HV 10 kV, LV 0.48 kV, Frecuencia 60 Hz, Impedancia 4%, Conexión Delta-Wye (IEEE Std), Enfriamiento ONAN, Estándar IEEE C57 / ANSI C84.1.
Q¿Se puede pedir S11-R-M-50/10/0.48 a medida?
Sí. QDTB® proporciona servicios integrales de personalización OEM/ODM. Se pueden ajustar parámetros como capacidad, relación de voltaje, método de enfriamiento, grupo de conexión y clase de protección. Más de 25 años de experiencia en fabricación garantizan una calidad constante.
Q¿Cómo conseguir presupuesto y documentación técnica?
Póngase en contacto a través del botón "Enviar consulta" a continuación, o comuníquese con ventas en Alice@qdtb-transformer.com / +86 13698683193. Le proporcionamos cotizaciones detalladas y documentación técnica al instante.
Productos relacionados en la Serie S11
¿Interesado en S11-R-M-50/10/0.48?