S13-M.RL-800/10
Wound Core Transformers Serie • 800kVA • 10/0.4 kV
S13-M.RL-800/10 is a 800 kVA, 10/0.4 kV transformadore sumergidos en aceite manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEC 60076, vector group Dyn11, short-circuit impedance 6%, approximate weight 1235 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.
Technical Specifications
| Model | S13-M.RL-800/10 |
|---|---|
| Rated Capacity | 800kVA |
| HV Voltage | 10 kV |
| LV Voltage | 0.4 kV |
| Input Voltage | 10kV |
| Output Voltage | 0.4kV |
| Frequency | 50/60 Hz |
| Vector Group | Dyn11 |
| Short-circuit Impedance | 6% |
| Cooling | ONAN |
| Insulation | A (105°C) |
| Temperature Rise | 65 K |
| No-load Loss | 980 W |
| Load Loss | 7500 W |
| Efficiency | 1Class 1 |
| Weight | 1235 kg |
| Dimensions (L x W x H) | 2625 x 1935 x 3180 mm |
| Applied Standard | IEC 60076 |
Puntos de operación típicos
Calculado a partir de las pérdidas de placa de este modelo (P₀ 980 W, P_k 7500 W), u_k 6%, con factor de potencia 0.9.
| Carga | Salida (kW) | Pérdida en vacío (kW) | Pérdida de carga (kW) | Pérdida total (kW) | Rendimiento (%) | Regulación de tensión (%) |
|---|---|---|---|---|---|---|
| 50% | 360.0 | 0.980 | 1.875 | 2.855 | 99.21 | 1.74 |
| 75% | 540.0 | 0.980 | 4.219 | 5.199 | 99.05 | 2.64 |
| 100% | 720.0 | 0.980 | 7.500 | 8.480 | 98.84 | 3.55 |
| 125% | 900.0 | 0.980 | 11.719 | 12.699 | 98.61 | 4.47 |
Rendimiento máximo en torno a 289 kVA (36.1% de la potencia nominal) — β* = √(P₀ / P_k).
Imagen y parámetros del producto

Las imágenes son sólo para fines ilustrativos.
S13-M.RL-800/10
Wound Core Transformers Serie
TECHNICAL DRAWING
Modelo: S13-M.RL-800/10 | Tipo: Transformador sumergido en aceite | Capacidad: 800 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
Especificaciones técnicas
LEGEND:
Descripción del Producto
Transformadores de núcleo bobinado S13-M.RL-800/10 Transformador de distribución de núcleo bobinado, nominal 800 kVA, entrada 10 kV, salida 0,4 kV, efecto GB 20052-2020 Nivel 13, frecuencia 50/60, peso 1235 kg, fabricante chino con certificación ISO
Palabras clave relacionadas
Calculadora de cotización y selección instantánea
Seleccione sus especificaciones para obtener un precio estimado al instante.
Más opciones(6)
Certificación
Los valores a continuación se calculan a partir de lo que seleccionó arriba. Todo lo que aún no se puede calcular se muestra como un guion largo — nunca como cero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Aún se requiere para completar el cálculo: capacidad nominal S,tensión de impedancia uₖ,corriente admisible de corta duración o de cresta.
Los valores por modelo (P0 / Pk / uₖ declarados por fábrica, pérdidas, ruido, elevación de temperatura, dimensiones, peso) no están en la biblioteca de productos: esas filas permanecen con un guion largo hasta que se suministre la hoja de parámetros de fábrica. Un guion largo significa que el valor no está disponible — nunca se representa como cero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)
Los precios de referencia son sólo para estimación y no constituyen una oferta formal.
3 · Solicita esta cotización
Le responderemos con la última cotización al instante.
S13-M.RL-800/10 - Preguntas frecuentes
Q¿Cuáles son las principales aplicaciones de S13-M.RL-800/10?
S13-M.RL-800/10 (serie Wound Core Transformers, Transformadores sumergidos en aceite) se usa ampliamente en Distribución de energía industrial, edificios comerciales y sistemas de energía de servicios públicos.. Se puede configurar de forma flexible según los requisitos reales del proyecto.
Q¿Cuáles son las principales especificaciones técnicas de S13-M.RL-800/10?
Especificaciones clave: Capacidad: 800kVA, HV 10 kV, LV 0.4 kV, Frecuencia 50/60 Hz, Impedancia 6%, Conexión Dyn11 (IEC), Enfriamiento ONAN, Estándar IEC 60076.
Q¿Se puede pedir S13-M.RL-800/10 a medida?
Sí. QDTB® proporciona servicios integrales de personalización OEM/ODM. Se pueden ajustar parámetros como capacidad, relación de voltaje, método de enfriamiento, grupo de conexión y clase de protección. Más de 25 años de experiencia en fabricación garantizan una calidad constante.
Q¿Cómo conseguir presupuesto y documentación técnica?
Póngase en contacto a través del botón "Enviar consulta" a continuación, o comuníquese con ventas en Alice@qdtb-transformer.com / +86 13698683193. Le proporcionamos cotizaciones detalladas y documentación técnica al instante.
Productos relacionados en la Serie Wound Core Transformers
¿Interesado en S13-M.RL-800/10?
Contáctenos para conocer precios, soporte técnico o requisitos personalizados.