结果
输入您的负载 → 数秒内获得完整设计及 BOM
示例输出Decoded model
S13-M-1000/10
Three-phase oil-immersed transformer (fully sealed)
Decoded parameters
| Parameter | Value |
|---|---|
| Type | Three-phase oil-immersed transformer (fully sealed) |
| Phases | Three-phase |
| Efficiency level | Loss level 13 (S13/SCB13 — grade 3, high efficiency) |
| Rated capacity | 1000 kVA |
| HV winding voltage | 10 kV |
| Winding material | Copper (default — confirm on nameplate) |
| Tap changer | Off-circuit / no-load tap changer |
Scope
This decoder covers distribution power transformers — oil-immersed (S/D series, GB/T 6451) and dry-type (SCB/SC/SG, JB/T 3837). Single-phase control transformers, three-phase control transformers, voltage regulators (TND/SVC/SBW), variable transformers (TDGC2/TSGC2) and special isolation/control transformers are separate product lines outside this decoder — see the products page or contact us.
面向采购工程师、选型人员和技术人员,帮助解读中国及 IEC 变压器型号命名中所编码的含义。
使用计算器
计算示例
预先计算的参考示例(可抓取——无需 JavaScript)。在上方输入您自己的参数以获取实时结果。
示例 1 — S13-M-1000/10(油浸式,2 级)
Decoded model
S13-M-1000/10
Three-phase oil-immersed transformer (fully sealed)
Decoded parameters
| Parameter | Value |
|---|---|
| Type | Three-phase oil-immersed transformer (fully sealed) |
| Phases | Three-phase |
| Efficiency level | Loss level 13 (S13/SCB13 — grade 3, high efficiency) |
| Rated capacity | 1000 kVA |
| HV winding voltage | 10 kV |
| Winding material | Copper (default — confirm on nameplate) |
| Tap changer | Off-circuit / no-load tap changer |
Scope
This decoder covers distribution power transformers — oil-immersed (S/D series, GB/T 6451) and dry-type (SCB/SC/SG, JB/T 3837). Single-phase control transformers, three-phase control transformers, voltage regulators (TND/SVC/SBW), variable transformers (TDGC2/TSGC2) and special isolation/control transformers are separate product lines outside this decoder — see the products page or contact us.
示例 2 — SCB13-1250/10/0.4 Dyn11(干式)
Decoded model
SCB13-1250/10/0.4DYN11
Three-phase cast-resin dry-type transformer
Decoded parameters
| Parameter | Value |
|---|---|
| Type | Three-phase cast-resin dry-type transformer |
| Phases | Three-phase |
| Efficiency level | Loss level 13 (S13/SCB13 — grade 3, high efficiency) |
| Rated capacity | 1250 kVA |
| HV winding voltage | 10 kV |
| LV winding voltage | 0.4 kV |
| Connection group | Dyn11 (delta HV / star LV, LV neutral, 30° lag) — standard distribution |
| Winding material | Copper (default — confirm on nameplate) |
| Tap changer | Off-circuit / no-load tap changer |
Scope
This decoder covers distribution power transformers — oil-immersed (S/D series, GB/T 6451) and dry-type (SCB/SC/SG, JB/T 3837). Single-phase control transformers, three-phase control transformers, voltage regulators (TND/SVC/SBW), variable transformers (TDGC2/TSGC2) and special isolation/control transformers are separate product lines outside this decoder — see the products page or contact us.
计算过程
- · 前缀字母:S = 三相油浸式,D = 单相,SCB/SG = 干式(浇注树脂/空气)。
- · 损耗等级数字:9/10/11/13/15/18/20/22 = 能效等级(数字越大 = 损耗越低)。
- · 后缀字母:M = 全密封,Z = 有载分接开关,L = 铝绕组。
- · 数字:容量/HV[/LV],单位为 kVA 和 kV。
- · 末尾组别:Dyn11、Yyn0、YNd11 等。
引用标准
| Standard | Scope |
|---|---|
| GB/T 6451 | 油浸式电力变压器的技术参数和要求 |
| JB/T 3837 | 变压器产品型号编制方法 |
| GB/T 10228 | 干式电力变压器的技术参数和要求 |
常见问题
变压器型号 S13-M-500/10 是什么意思?
S = 三相油浸式、13 = 损耗/能效等级、M = 密封式(全密封)、500 = 容量 kVA、10 = 高压侧电压 kV。即 500 kVA、10 kV 全密封油浸 S13 变压器。计算器解析完整型号串。
型号 SCB13-1000/10 是什么意思?
SCB = 三相干式浇注、13 = 损耗等级、1000 = 容量 kVA、10 = 高压侧电压 kV,B 表示箔式/带式绕组。即 1000 kVA、10 kV 浇注干式变压器。计算器解析 SCB、SC、SG 等前缀。
如何读 Dyn11 这样的联结组别?
Dyn11 = 高压角接(D)、低压星接带中性点(y+n),11 点钟相位差表示低压滞后高压 30°(11×30=330° 超前)。Yyn0 = 星/星带中性点、0° 移相。计算器在解析结果中说明联结组别。
字母 S9、S11、S13、S20、S22 是什么意思?
这些是中国油浸式变压器按损耗等级分的系列:S9 为老标准,S11、S13 逐级降空载损耗约 20-30%,S20/S22 满足现行 GB 20052 一级/二级能效。数字越大损耗越低、价格越高。计算器把系列对应到能效等级。
为什么需要解析变压器型号?
型号以紧凑串编码类型、冷却、容量、电压和损耗等级,解析后可核对报价、比标或匹配替换。看错一位就可能买错电压或容量。计算器把型号串解析成明文字段。
嵌入此计算器
将此计算器免费添加到您自己的网站。iframe 可自适应任何宽度,并完全在访问者的浏览器中运行。
发送我的完整设计报告
免费获取完整设备清单(BOM)、单线图、计算步骤与 FOB 报价的 PDF 报告,无需注册。
您的信息仅用于回复询盘,不用于任何其他用途。