🔌 Kalkulator Penentuan String PV
Rancang string PV terhadap batas tegangan inverter Anda: Voc dan Vmp terkoreksi suhu, jendela MPPT, dan rasio DC/AC. Mencegah tegangan berlebih saat cuaca dingin dan tegangan kurang saat cuaca panas.
🔌 Module & Inverter
📊 String Design
Untuk perancang dan pemasang tenaga surya yang menentukan string sesuai spesifikasi inverter.
Cara menghitungnya
· Voc dingin: Voc_maks = Voc × (1 + α × (Tmin − 25) ÷ 100), α ≈ −0.34 %/°C.
· Vmp panas: Vmp_min = Vmp × (1 + α × (Tmax − 25) ÷ 100).
· Modul maksimum = floor(Vmaks ÷ Voc_maks); modul minimum = ceil(MPPT_min ÷ Vmp_min); target ≈ Vmaks × 0.85 ÷ Vmp.
Standar yang dirujuk
| Standard | Scope |
|---|---|
| IEC 62548 | Larik fotovoltaik — persyaratan desain |
| NEC 690.7 | Tegangan maksimum sistem PV |
Contoh perhitungan — modul 550 W, inverter 10 kW
1. Modul 550 W (Voc 49.5 V, Vmp 41.5 V), inverter 10 kW (Vmaks 1000 V, MPPT 90–520 V), Tmin −10 °C, Tmax 60 °C.
2. Voc dingin = 49.5 × (1 − 0.0034 × (−35)) = 55.4 V; Vmp panas = 41.5 × (1 − 0.0034 × 35) = 36.6 V.
3. Modul maksimum = floor(1000 ÷ 55.4) = 18; minimum = ceil(90 ÷ 36.6) = 3.
4. Rekomendasi ≈ round(1000 × 0.85 ÷ 41.5) = 18 modul per string.
FAQ
How do I size a PV string against inverter voltage limits?
The string's temperature-corrected open-circuit voltage Voc must stay below the inverter maximum (commonly 1000 V or 1500 V), and the operating voltage Vmp must stay inside the MPPT window. Use the module temperature coefficients: Voc rises roughly 0.25-0.35%/deg C below 25 deg C. A 550 W module with Voc 49.5 V allows about 18-20 in series at -10 deg C on a 1000 V inverter.
What DC/AC ratio should a PV system use?
DC/AC ratio is array DC capacity divided by inverter AC rating. Typical values are 1.1-1.3 for most sites, up to 1.5 in high-latitude or high-albedo locations, to capture more energy when modules rarely reach STC output. Over 1.3-1.4 the inverter clips more peak power, and the marginal energy gain falls below the extra module cost.
Why does temperature affect PV string voltage?
Solar cell voltage drops as temperature rises. Module datasheets give temperature coefficients, typically -0.29%/deg C for Voc and -0.34%/deg C for power. At -10 deg C the voltage is about 10% above the 25 deg C value, so strings must be short enough not to exceed inverter limits in winter; at 70 deg C the voltage is ~13% lower, so strings must stay above the MPPT minimum.
How many modules per string is typical for a 550 W module?
With a 550 W module (Voc ~49.5 V, Vmp ~41.5 V) on a 1500 V inverter, strings of 28-32 modules are common; on a 1000 V inverter, 18-22 modules. The exact count depends on the minimum site temperature and the inverter MPPT range, so the calculator checks both the -10 deg C Voc and the 70 deg C Vmp bounds.
What is the difference between 1000 V and 1500 V PV systems?
1500 V systems allow longer strings (fewer combiner boxes, less cable and DC loss) and cut balance-of-system cost about 3-8% for utility plants, but need 1500 V-rated modules, inverters and protection. 1000 V remains standard for rooftop and small C&I. The calculator's string designer supports both voltage classes.
Sematkan kalkulator ini
Tambahkan kalkulator ini ke situs web Anda sendiri secara gratis. Iframe menyesuaikan dengan lebar apa pun dan berjalan sepenuhnya di peramban pengunjung Anda.
Alat terkait
Perkiraan referensi (FOB Qingdao, EXW) untuk desain awal saja — bukan penawaran final. Konfirmasikan ukuran terhadap proyek dan standar lokal Anda.
Send my complete design report
Get the full bill of materials, single-line diagram, calculation steps and FOB pricing as a PDF — free, no sign-up.
Your data stays private. No spam — only a reply to your enquiry.