ZGS-Z-10-833

ZGS Series • 833 kVA • 12/0.4 kV

TECHNICAL DRAWING

Model: ZGS-Z-10-833 | Type: Oil-immersed transformer | Capacity: 833 kVA

Product photo

ZGS - QDTB

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.2035mm2500mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11 (IEEE)

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

ZGS-Z-10-833 is a 833 kVA, 12/0.4 kV american pad-mounted transformer manufactured by Shandong Yaqing Electrical Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with GB/T 17467, IEEE C57, ANSI C57, vector group Dyn11 (IEEE), short-circuit impedance 4.5%, approximate weight 5665 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

Full technical specification

Every value below is the guaranteed figure for this model. Where a parameter depends on the site, the design basis is stated.

ZGS-Z-10-833
01

Electrical data

Electrical data
Rated power833 kVA
HV winding12 kV
LV winding0.4 kV
Frequency50 Hz
Impedance voltage at 75 °C4.5 %
Vector groupDyn11 (IEEE)
Cooling methodONAN
No-load loss1009 W
Load loss at 75 °C7962 W
Efficiency at full load, unity power factorS11 %
No-load current0.5 %
HV current40.08 A
LV current1202.33 A
Tap changerNLTC ±2×2.5%
02

Insulation and dielectric

Insulation and dielectric
BIL, HV winding95 kV
BIL, LV winding30 kV
Temperature rise, average winding65 K
Hot-spot allowance80 K
Insulation classA (105°C)
03

Mechanical

Mechanical
Total weight5665 kg
Dimensions (L x W x H)2835×2035×2500 mm
Core constructionsilicon-steel
Winding materialcopper
04

Compliance and standards

Compliance and standards
Compliance and standardsGB/T 17467, IEEE C57, ANSI C57
Loss tolerance+10 % on total losses, +10 % on each component (guaranteed values)
Short-circuit withstand25 × rated current for 2 s · Category I (≤ 2.5 MVA)
Overload capability100 % of rating at 65 K rise, 40 °C ambient
Paint systemC4 (high durability, industrial / urban atmosphere)
Protection LevelIP54
05

Testing and acceptance

Routine tests — performed on every unit

  • Winding resistance measurement
  • Voltage ratio and polarity / phase relation
  • No-load loss and excitation current
  • Load loss and impedance voltage
  • Applied potential test
  • Induced potential test
  • Insulation resistance
  • Insulating oil dielectric strength

Type tests — design-proven, certificates available

  • Temperature rise test
  • Lightning impulse withstand (BIL)
  • Sound level measurement
  • Short-circuit withstand (IEC 60076-5)
06

Supply scope

Included in the supply

  • Buchholz relay (gas and oil-surge protection)
  • Pressure relief valve
  • Oil level gauge
  • Dial-type oil thermometer
  • Drain valve and filter valve
  • Lifting lugs
  • Earthing terminals (tank and neutral)
  • Rating plate
  • HV and LV bushings
  • Transformer as specified
  • Fittings listed above
  • Routine test report
  • Rating plate and outline drawing
  • Packing for the agreed mode of transport

Not included

  • Foundation and civil works
  • Cable termination and glands
  • Switchgear and protection relays
  • Installation and commissioning labour
  • Spare parts unless ordered
07

Installation and operating conditions

Installation and operating conditions
Design ambient temperature40 °C
Design altitude1000 m
Pollution degreePollution degree III (outdoor), creepage per IEC 60815

Reference network study

Reference network, not a project-specific study

Results below come from a steady-state study of this transformer inside a standard reference network, computed at build time. They describe the reference case only — a real project depends on the actual grid strength, cable runs, load profile and protection settings.

Prospective short-circuit current at LV busbar27.00 kA
Voltage deviation at the reference load point2.90 %
Hot-spot temperature at the reference load89.1 °C (limit 140 °C)
Harmonic voltage distortion limit at this voltage level5 % THD
Inrush current at energisation10× rated peak · 17 kA peak
Transformer loading in the reference network71.1 %
Short-circuit impedance used4.5 %
Prospective short-circuit current at transformer LV terminals (uk only, no cable)26.72 kA
Reference network assumptions
  • HV busbar reference; the reported short-circuit current is set by the transformer uk alone (upstream grid impedance not included)
  • 10 m Cu cable, 120 mm², in air
  • 20 m Cu cable, 240 mm², in air
  • 80 % of transformer rating at cos φ = 0.90
  • Steady-state reference network, not a project-specific study
  • transformer model: ZGS-Z-10-833 (833 kVA, 12 kV / 0.4 kV, uk 4.5 %)
  • losses used: P0 1009 W, Pk 7962 W ((this product's nameplate values))

Study computed at build time 2026-11-16 · engine: ESH / IEC 60909

Recalculate with your own networkEnter your grid short-circuit level, cable runs and load profile to get a project-specific result.
Open the working-point study — change load and ambient temperature

Hot-spot and winding temperature are recomputed on the reference network as you move the load between 40 % and 100 %. Short-circuit current stays fixed — it is set by the transformer impedance.

Product Description

ZGS-Z-10-833 American pad-mounted transformer substation. Dead-front SF6 load break switch, bayonet fuse, pressure relief valve. For residential and light commercial distribution.

ZGS-Z-10-833 - Frequently Asked Questions

QWhat is the impedance voltage of the ZGS-Z-10-833?

The ZGS-Z-10-833 has an impedance voltage of 4.5 % at rated current, measured at 75 °C. Tolerance is plus or minus 7.5 % unless otherwise agreed, per IEEE C57.12.00 Table 16.

QWhat is the efficiency of the ZGS-Z-10-833?

At full load and unity power factor the ZGS-Z-10-833 reaches S11 % efficiency, with 1009 W no-load loss and 7962 W load loss at 75 °C.

QWhat insulation level does the ZGS-Z-10-833 have?

The HV winding is rated 95 kV BIL and the LV winding 30 kV BIL, per IEEE C57.12.00 Table 1 for the 12 kV / 0.4 kV voltage class.

QWhat tests are performed before shipment?

Every unit receives 8 routine tests per IEEE C57.12.90, including winding resistance, voltage ratio, no-load loss and excitation current, load loss and impedance, applied potential, induced potential and insulation resistance. The test report is issued with the unit.

QWhat is included in the supply of the ZGS-Z-10-833?

The transformer with its standard fittings, the routine test report, the rating plate and the outline drawing. Foundation, cable termination, switchgear, protection relays and installation labour are not included.

QWhat temperature rise and ambient conditions apply?

Average winding rise is 65 K with an 80 K hot-spot allowance, designed for 40 °C ambient at altitudes up to 1000 m. Above these values the rating is derated per IEEE C57.12.00.

QWhat are the main applications of ZGS-Z-10-833?

ZGS-Z-10-833 (ZGS series, American Pad-Mounted Transformers) is widely used in industrial power distribution, commercial buildings and utility power systems. Can be flexibly configured according to actual project requirements.

QCan ZGS-Z-10-833 be custom ordered?

Yes. QDTB® provides comprehensive OEM/ODM customization services. Parameters such as capacity, voltage ratio, cooling method, connection group and protection class can all be adjusted. Over 25 years of manufacturing experience ensures consistent quality.

QDoes ZGS-Z-10-833 stay within its temperature rise limit at rated load?

At rated load with 40 °C ambient, the hot-spot temperature of ZGS-Z-10-833 reaches 89.1 °C, which is within the 140 °C limit of IEC 60076-2 for this insulation class. The winding average temperature rise is 40.9 K. Values follow the IEC 60076-7 exponential thermal model at 80 % loading in a reference network; site ambient temperature and actual load profile must be verified for a specific project.

QWhat is the prospective short-circuit current at the LV busbar of ZGS-Z-10-833?

In the standard reference network used across this catalogue - 10 m Cu 120 mm² HV cable, 20 m Cu 240 mm² LV cable in air, load at 80 % of rating with cos φ = 0.90 - the prospective short-circuit current at the LV busbar of ZGS-Z-10-833 is 27.00 kA. It is set by this unit short-circuit impedance of 4.5 % alone; upstream grid impedance is not included, so it is a conservative upper bound. Voltage deviation at the reference load point is 2.90 % and transformer loading is 71.1 %. This is a reference-network result, not a project-specific study.