Product Search
Find the right transformer for your needs
SCADA & Secondary Automation
6 Series · 16 Models
Product Images
Images are for illustration purposes only
SCADA & Secondary Automation Overview
Substation SCADA and secondary automation equipment for MV/LV distribution systems — protection IEDs, DC auxiliary panels, SCADA stations, RTUs, communication managers, MIMIC panels and multifunction meters. IEC 61850 / IEC 60870-5-104.
Available Series

Protection IED Series
Multifunction protection IEDs for MV feeders, incomers and bus-ties with overcurrent, differential, voltage and frequency protection, RS485 and Ethernet communication.

DC Panel Series
DC auxiliary panels with battery charger and battery bank for protection tripping, motor operation and relay power supply, in 24–100 Ah ratings.

Protection & Control Series
Arc flash protection, automatic bus transfer (BZT), LV intelligent release and motor protection relays for switchgear groups, dual-incomer substations, ACBs and MCC feeders.

SCADA & Monitoring Series
SCADA monitoring stations, remote terminal units, local HMI touchscreens, GPS/BeiDou time synchronization and MIMIC panels for station control-room monitoring and dispatch.

Communication Series
Communication managers for protocol conversion and industrial managed Ethernet switches for ring-network communication in substations.

Metering Series
Multifunction energy meters for feeder and incomer metering, and 0.2S class revenue meters for billing boundaries.
Related Engineering Calculators
Free sizing and pricing tools for this product category.
Application Scenarios
Substation Turnkey Projects
Complete protection, DC power and SCADA layer for MV/LV substations.
Data Centers
Protection IEDs, DC panels and SCADA for fault-tolerant power distribution.
Industrial Plants & Oilfield
Motor protection, arc flash protection and prepaid metering for process and oilfield power systems.
Hospitals & Public Facilities
Medical IT isolation systems plus protection, metering and SCADA for critical facilities.
Technical Advantages
F
u
I
E
B
a
F
O
FAQ - SCADA & Secondary Automation
What is secondary automation in a substation?
Which protocol should I choose?
Do you supply the SCADA engineering?
What is the minimum order quantity (MOQ) for SCADA & Secondary Automation?
What is the delivery time for SCADA & Secondary Automation?
Which standards and certifications do your SCADA & Secondary Automation comply with?
Related Product Categories
Dry Type Transformers
Dry-type transformers are essential components in modern ele
Oil Immersed Transformers
Oil-immersed transformers are the workhorse of power distrib
Special Isolation Control Transformers
Isolation and control transformers provide galvanic separati
Amorphous Alloy Transformers
Amorphous alloy transformers are the lowest-loss choice for
Box Type Substations
Box-type substations, also known as prefabricated substation
Reactors
Reactors are inductive components that shape power quality b
Cable Branch Boxes
Cable branch boxes are sealed distribution points that split
Ring Main Units
Ring main units (RMUs) are compact, sealed switchgear that f
High Voltage Switchgear
High-voltage switchgear performs switching, protection, and
Low Voltage Switchgear
Low-voltage switchgear and motor control centers (MCCs) deli
Single Phase Transformers
Single-phase control transformers provide galvanic isolation
Three Phase Transformers
Three-phase dry-type transformers step down, isolate, or ada
Voltage Regulators
Automatic voltage regulators (stabilizers) keep output volta
Variable Transformers
Variable auto-transformers deliver continuous, stepless AC v
Inverters
Pure sine wave inverters convert DC battery power (12 V/24 V
Dc Power Supplies
Switching DC power supplies convert AC mains into regulated
Battery Chargers
Intelligent battery chargers restore and maintain lead-acid
Motor Starters
Motor starters control three-phase motor energization with r
Ups
Online double-conversion UPS systems continuously regenerate
Power Capacitors
Self-healing power capacitors provide power factor correctio
Solar Pv Modules
Solar PV modules convert sunlight into direct current and ar
String Inverters
String grid-tie inverters turn the DC output of PV modules i
Hybrid Inverters
Hybrid solar inverters combine a grid-tie inverter and a bat
Energy Storage Batteries
Energy storage batteries store surplus solar or off-peak pow
Pcs Energy Storage
Power conversion systems (PCS) are the bidirectional heart o
Battery Management Systems
The battery management system is the safety and intelligence
Ess Fire Suppression
Fire suppression for energy storage must act in the seconds
Pv Mounting Structures
Mounting structures hold the array to the roof or ground for
Dc Cables Connectors Spd
The DC side of a PV plant is only as reliable as the cables,
Monitoring Scada Communication
A solar or storage plant that cannot be observed and control
Cables Trays Grounding
The AC side and the structural grounding of a plant are easy
Energy Storage Containers
The energy storage container packages battery, power convers
Busway
Busway (bus duct) systems distribute high-current power from
Ev Charging Stations
EV charging stations supply electric vehicles with AC Level
Pole Mounted Switchgear
Pole-mounted switchgear provides outdoor switching, protecti
Svg Svc
Static Var Generator (SVG) and Static Var Compensator (SVC)
Active Harmonic Filters
Active Harmonic Filters (APF), also called active power filt
Ats Transfer Switches
Automatic Transfer Switches (ATS) automatically transfer the
Diesel Generators
Diesel generator sets provide reliable prime or standby powe
Eps Emergency Power
EPS (Emergency Power Supply) systems provide battery-backed
Wind Turbines
QDTB onshore wind turbines span the 2 MW, 3 MW and 5 MW clas
American Pad Mounted Transformers
American pad-mounted transformers (ZGS series) place a 12 kV
Need help?
All specifications and dimensions can be customized upon request
Protection Relay (IED) vs RTU vs SCADA Station: How to Choose
| Protection Relay (IED) | RTU | SCADA Station | |
|---|---|---|---|
| Function | Protects the feeder or transformer and trips the breaker | Collects signals and passes them to the control centre | Supervises, archives, alarms and controls the substation |
| Protocols | IEC 61850, with IEC 60870-5-104 gateway options | IEC 60870-5-104 and Modbus to the dispatch centre | IEC 61850 and IEC 60870-5-104 across the station |
| Mounting | Panel mounted in the switchgear compartment | DIN rail or panel in the control cabinet | Server and workstations in the control room |
| Redundancy | Single device, with a backup scheme where required | Dual communication paths to the centre | Redundant servers and networks |
| Integration | Feeds the station bus with protection data | Bridges legacy devices onto one protocol | Pulls every device into one model and one HMI |
| Cost | Lowest per point protected | Middle | Highest, including engineering and commissioning |
| Typical application | Feeder, transformer and motor protection | Telecontrol of small and remote sites | Substation turnkey projects and dispatch centres |
Where QDTB® SCADA & Secondary Automation Are Specified
Secondary automation is specified as a layer rather than a box: protection IEDs at the switchgear, RTUs where a remote site has to be telemetered, DC auxiliary panels that keep the protection alive when AC fails, and a SCADA station where the operator actually sits. Each device has a different job, and the substation only works when the layer is designed as a whole.
Substation turnkey projects specify IEC 61850 inside the station and IEC 60870-5-104 to the dispatch centre, because the utility's control system and the station bus rarely speak the same language. Communication managers and time synchronisation are what make the two ends agree.
Data centres, hospitals and industrial plants use the same equipment for their own medium-voltage rooms. Protection, metering and a MIMIC panel are needed there even though there is no utility dispatch centre to report to.
The scope covers protection IEDs, DC panels, SCADA stations, RTUs, communication managers, MIMIC panels and multifunction meters. Units are engineered to IEC 60255-151 and IEC 60870-5-104, with IEC 61850 where the station is specified that way.
Frequently Asked Questions
What is secondary automation in a substation?
Secondary automation covers the protection, control, metering and communication layer — protection IEDs, DC panels, SCADA stations, communication managers and meters — that keeps a primary (switchgear/transformer) system safe and remotely operable.
Which protocol should I choose?
Modbus RTU/TCP for simple sites, IEC 60870-5-104 for dispatch telecontrol, and IEC 61850 (GOOSE/SV) for modern interoperable substations.
Do you supply the SCADA engineering?
SCADA station pricing includes basic configuration; detailed engineering and installation are quoted separately per project.
What is the minimum order quantity (MOQ) for SCADA & Secondary Automation?
One unit for standard products. Custom-designed equipment is quoted on specifications — send your parameters or drawings and our sales team will confirm the MOQ for your configuration.
What is the delivery time for SCADA & Secondary Automation?
Standard units are delivered in 30-45 days. Custom or large-capacity units follow a project-specific schedule confirmed at quotation. Rush orders can be accommodated for urgent projects.
Which standards and certifications do your SCADA & Secondary Automation comply with?
They are designed and tested to IEC 60255-151; IEC 61850 (optional), IEC 60870-5-104, DL/T 5044. All QDTB® equipment is ISO 9001 certified and CE marked, and the company operates ISO 9001, ISO 14001 and ISO 45001 management systems.