Motor Starters
4 Series · 55 Models
Product Images
Images are for illustration purposes only
Motor Starters Overview
Motor starters control three-phase motor energization with reduced-voltage methods that limit inrush current and mechanical stress. QDTB cabinets offer star-delta (Y-delta), auto-transformer, and electronic soft starting for motors from 2.2 kW to hundreds of kilowatts at 380 V/440 V/660 V. Series QX4 (star-delta), JJ01 (auto-transformer), and RS/RC (soft start) reduce starting current 3-5 times with overload, phase-loss, and short-circuit protection for pumps, fans, compressors, conveyors, and crushers.
Available Series

QX4 Series
The QX4 series motor starting control cabinets provide complete motor starting solutions including direct-on-line, star-delta, and auto-transformer starting methods.

JJ01 Series
The JJ01 series liquid resistance motor starters provide smooth, stepless starting for large slip-ring induction motors using liquid rheostat technology.

RS Series
The RS series electronic soft starters use thyristor technology for smooth, controlled acceleration of three-phase induction motors with reduced mechanical stress.

RC Series
The RC series motor running control cabinets provide complete motor control and protection solutions including speed control, reversing, and multi-motor coordination.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(4)
Certification
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.
Application Scenarios
Pumps & Water Systems
Reduced-voltage starting protects pumps from mechanical and electrical shock.
Large Fans & Blowers
Soft starting for HVAC and industrial fans with high inertia.
Air Compressors
Cuts starting current and mechanical stress on compressor motors.
Conveyors & Material Handling
Smooth starts for conveyors, avoiding belt slip and load shock.
Crushers & Mills
Handles high-inertia, heavy-starting loads in mining and aggregates.
HVAC Systems
Reduced inrush for chillers, compressors and pumps in buildings.
Technical Advantages
Multiple Starting Methods
Star-delta, auto-transformer and electronic soft-start from one supplier.
Reduced Starting Current
Cuts starting current 3-5x, protecting the motor and supply network.
Comprehensive Protection
Overload, phase-loss, short-circuit and under-voltage protection.
Wide Power Range
From 2.2 kW to hundreds of kW across the product families.
FAQ - Motor Starters
What is the difference between star-delta and soft start?
When should I use a soft starter?
Can it start heavy loads?
What capacity and voltage range is available for Motor Starters?
What is the minimum order quantity (MOQ) for Motor Starters?
What is the delivery time for Motor Starters?
Related Product Categories
Dry Type Transformers
Dry-type transformers are essential components in modern ele
Oil Immersed Transformers
Oil-immersed transformers are the workhorse of power distrib
Special Isolation Control Transformers
Isolation and control transformers provide galvanic separati
Amorphous Alloy Transformers
Amorphous alloy transformers are the lowest-loss choice for
Box Type Substations
Box-type substations, also known as prefabricated substation
Reactors
Reactors are inductive components that shape power quality b
Cable Branch Boxes
Cable branch boxes are sealed distribution points that split
Ring Main Units
Ring main units (RMUs) are compact, sealed switchgear that f
High Voltage Switchgear
High-voltage switchgear performs switching, protection, and
Low Voltage Switchgear
Low-voltage switchgear and motor control centers (MCCs) deli
Single Phase Transformers
Single-phase control transformers provide galvanic isolation
Three Phase Transformers
Three-phase dry-type transformers step down, isolate, or ada
Voltage Regulators
Automatic voltage regulators (stabilizers) keep output volta
Variable Transformers
Variable auto-transformers deliver continuous, stepless AC v
Inverters
Pure sine wave inverters convert DC battery power (12 V/24 V
Dc Power Supplies
Switching DC power supplies convert AC mains into regulated
Battery Chargers
Intelligent battery chargers restore and maintain lead-acid
Ups
Online double-conversion UPS systems continuously regenerate
Power Capacitors
Self-healing power capacitors provide power factor correctio
Solar Pv Modules
Solar PV modules convert sunlight into direct current and ar
String Inverters
String grid-tie inverters turn the DC output of PV modules i
Hybrid Inverters
Hybrid solar inverters combine a grid-tie inverter and a bat
Energy Storage Batteries
Energy storage batteries store surplus solar or off-peak pow
Pcs Energy Storage
Power conversion systems (PCS) are the bidirectional heart o
Battery Management Systems
The battery management system is the safety and intelligence
Ess Fire Suppression
Fire suppression for energy storage must act in the seconds
Pv Mounting Structures
Mounting structures hold the array to the roof or ground for
Dc Cables Connectors Spd
The DC side of a PV plant is only as reliable as the cables,
Monitoring Scada Communication
A solar or storage plant that cannot be observed and control
Cables Trays Grounding
The AC side and the structural grounding of a plant are easy
Energy Storage Containers
The energy storage container packages battery, power convers
Busway
Busway (bus duct) systems distribute high-current power from
Ev Charging Stations
EV charging stations supply electric vehicles with AC Level
Pole Mounted Switchgear
Pole-mounted switchgear provides outdoor switching, protecti
Svg Svc
Static Var Generator (SVG) and Static Var Compensator (SVC)
Active Harmonic Filters
Active Harmonic Filters (APF), also called active power filt
Ats Transfer Switches
Automatic Transfer Switches (ATS) automatically transfer the
Diesel Generators
Diesel generator sets provide reliable prime or standby powe
Eps Emergency Power
EPS (Emergency Power Supply) systems provide battery-backed
Wind Turbines
QDTB onshore wind turbines span the 2 MW, 3 MW and 5 MW clas
Scada Automation
Substation SCADA and secondary automation equipment for MV/L
American Pad Mounted Transformers
American pad-mounted transformers (ZGS series) place a 12 kV
Need help?
All specifications and dimensions can be customized upon request
Star-Delta vs Auto-Transformer vs Soft Starter: How to Choose
| Star-Delta (QX4) | Auto-Transformer (JJ01) | Electronic Soft Starter (RS/RC) | |
|---|---|---|---|
| Starting current | Cut to roughly a third of the direct-on-line value | Set by the tap chosen on the transformer | Ramped smoothly from a set initial value |
| Starting torque | Also cut to about a third, which is the limitation | Higher than star-delta at the same current | Adjustable, so torque follows the load |
| Torque transition | Torque step at the star-delta changeover | Step at each tap change | No step, because the ramp is continuous |
| Cost | Lowest of the three | Higher, because of the transformer | Highest, driven by the thyristor stage |
| Panel size | Compact | Bulky, dominated by the transformer | Compact, with heat to manage |
| Load suitability | Fans, pumps and loads that start unloaded | Large motors on a supply that cannot take the inrush | Pumps and conveyors where water hammer or belt slip matters |
| Typical application | Pumps, blowers and compressors | Crushers and mills on weak supplies | HVAC, conveyors and process lines |
Where QDTB® Motor Starters Are Specified
Motor starters are specified wherever a three-phase motor is too large to start direct-on-line on the supply available: pumps and water systems, large fans and blowers, air compressors, conveyors and crushers. The starter limits inrush and mechanical stress at the same time, so it protects the network and the driven machine together.
Star-delta remains the default on loads that start unloaded, because it is the lowest-cost way to cut starting current. Auto-transformer starting is chosen where the motor still needs torque at start-up, and soft starters where a smooth ramp removes water hammer, belt slip or product damage on the line.
HVAC and process plants use soft starters on fans and conveyors where the ramp profile has to match the load. The bypass contactor sits in the same cabinet, so the thyristor stage drops out of circuit once the motor is up to speed.
Cabinets cover 14 kW to 320 kW at the common three-phase supply voltages. Overload, phase-loss and short-circuit protection are included to GB/T 14048.4 and IEC 60947-4-1, and the starting method is selected from the load torque curve.
Frequently Asked Questions
What is the difference between star-delta and soft start?
Star-delta switches winding configuration to reduce starting current but causes a torque step. A soft starter ramps voltage smoothly for a gentler, more controllable start.
When should I use a soft starter?
For pumps, fans and compressors where a smooth start reduces water hammer, belt slip and mechanical wear, or when the supply is weak.
Can it start heavy loads?
Yes. Select the starting method and rating for the load's inertia and required starting torque.
What capacity and voltage range is available for Motor Starters?
QDTB® supplies Motor Starters from 14 to 320 kW.
What is the minimum order quantity (MOQ) for Motor Starters?
One unit for standard products. Custom-designed equipment is quoted on specifications — send your parameters or drawings and our sales team will confirm the MOQ for your configuration.
What is the delivery time for Motor Starters?
Standard units are delivered in 30-45 days. Custom or large-capacity units follow a project-specific schedule confirmed at quotation. Rush orders can be accommodated for urgent projects.