QDTB® Transformer

Product Search

Find the right transformer for your needs

🔌

Inverters (DC-AC)

2 Series · 5 Models

Product Images

QDTB® Inverters (DC-AC)

Images are for illustration purposes only

Inverters (DC-AC) Overview

Pure sine wave inverters convert DC battery power (12 V/24 V/36 V/48 V) into clean, grid-quality 220 V AC. QDTB models span 0.5 kW to 10 kW at 50/60 Hz with conversion efficiency above 85% and automatic overload, short-circuit, over-temperature, and over-voltage protection. Pure sine wave output is compatible with sensitive electronics, motors, and inductive loads, serving solar systems, marine vessels, remote sites, backup power, and telecom.

2
Product Series
5+
Available Models
ISO
Certified Quality

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
2 · Your price
EXW (FOB Qingdao)
$116
Range $107 ~ $1268%)
Price Breakdown
Base price (interpolation)$116
× Product factor×1.0000
× Country factor×1.0000
× Copper-linked factor×1.0000
+ Options / accessories$0
Shipping quoted separately per destination port.

Complete equipment — no winding copper linkage

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.

Application Scenarios

Off-Grid Solar

Converts battery DC to AC for homes and systems not connected to the grid.

Marine & RV

Runs appliances from the battery bank on boats, yachts and motorhomes.

Backup Power

Keeps essential loads running during outages from a battery source.

Telecommunications

Remote-site power for telecom and monitoring equipment.

Remote & Rural Areas

Reliable AC where grid power is unavailable or unreliable.

Mobile & Field Work

Portable AC for tools, lighting and equipment on work sites.

Technical Advantages

1

Pure Sine Wave

Clean output compatible with all sensitive electronics, motors and inductive loads.

2

High Efficiency

Conversion efficiency above 85% minimises battery drain.

3

Full Protection

Automatic overload, short-circuit, over-temperature and over-voltage shutdown.

4

Wide DC Input

12V/24V/36V/48V input options to match any battery bank.

FAQ - Inverters (DC-AC)

What is the difference between pure sine wave and modified sine wave?
Pure sine wave matches grid power and runs everything, including motors and sensitive electronics. Modified sine wave is cheaper but can damage or fail to run some loads.
What size inverter do I need?
Sum the running watts of your loads plus the surge of the largest motor. Choose an inverter rated above the peak, typically 1.5-2x continuous load.
Can it run inductive loads like motors?
Yes. Pure sine wave inverters handle motor starting surges; allow for 3-5x running current at start-up.

Related Product Categories

Dry Type Transformers

Dry-type transformers are essential components in modern ele

Oil Immersed Transformers

Oil-immersed transformers are the workhorse of power distrib

Special Isolation Control Transformers

Isolation and control transformers provide galvanic separati

Amorphous Alloy Transformers

Amorphous alloy transformers are the lowest-loss choice for

Box Type Substations

Box-type substations, also known as prefabricated substation

Reactors

Reactors are inductive components that shape power quality b

Cable Branch Boxes

Cable branch boxes are sealed distribution points that split

Ring Main Units

Ring main units (RMUs) are compact, sealed switchgear that f

High Voltage Switchgear

High-voltage switchgear performs switching, protection, and

Low Voltage Switchgear

Low-voltage switchgear and motor control centers (MCCs) deli

Single Phase Transformers

Single-phase control transformers provide galvanic isolation

Three Phase Transformers

Three-phase dry-type transformers step down, isolate, or ada

Voltage Regulators

Automatic voltage regulators (stabilizers) keep output volta

Variable Transformers

Variable auto-transformers deliver continuous, stepless AC v

Dc Power Supplies

Switching DC power supplies convert AC mains into regulated

Battery Chargers

Intelligent battery chargers restore and maintain lead-acid

Motor Starters

Motor starters control three-phase motor energization with r

Ups

Online double-conversion UPS systems continuously regenerate

Power Capacitors

Self-healing power capacitors provide power factor correctio

Solar Pv Modules

Solar PV modules convert sunlight into direct current and ar

String Inverters

String grid-tie inverters turn the DC output of PV modules i

Hybrid Inverters

Hybrid solar inverters combine a grid-tie inverter and a bat

Energy Storage Batteries

Energy storage batteries store surplus solar or off-peak pow

Pcs Energy Storage

Power conversion systems (PCS) are the bidirectional heart o

Battery Management Systems

The battery management system is the safety and intelligence

Ess Fire Suppression

Fire suppression for energy storage must act in the seconds

Pv Mounting Structures

Mounting structures hold the array to the roof or ground for

Dc Cables Connectors Spd

The DC side of a PV plant is only as reliable as the cables,

Monitoring Scada Communication

A solar or storage plant that cannot be observed and control

Cables Trays Grounding

The AC side and the structural grounding of a plant are easy

Energy Storage Containers

The energy storage container packages battery, power convers

Busway

Busway (bus duct) systems distribute high-current power from

Ev Charging Stations

EV charging stations supply electric vehicles with AC Level

Pole Mounted Switchgear

Pole-mounted switchgear provides outdoor switching, protecti

Svg Svc

Static Var Generator (SVG) and Static Var Compensator (SVC)

Active Harmonic Filters

Active Harmonic Filters (APF), also called active power filt

Ats Transfer Switches

Automatic Transfer Switches (ATS) automatically transfer the

Diesel Generators

Diesel generator sets provide reliable prime or standby powe

Eps Emergency Power

EPS (Emergency Power Supply) systems provide battery-backed

Wind Turbines

QDTB onshore wind turbines span the 2 MW, 3 MW and 5 MW clas

Scada Automation

Substation SCADA and secondary automation equipment for MV/L

Need help?

All specifications and dimensions can be customized upon request