S11-R-M-3150/0.48/0.208
S11 Series • 3150 kVA • 0.48/0.208 kV
Product Image & Parameters
S11-R-M-3150/0.48/0.208
S11 Series
Capacity
3150kVA
HV Voltage
0.48kV
LV Voltage
0.208kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss
TECHNICAL DRAWING
Model: S11-R-M-3150/0.48/0.208 | Type: Dry-Type Transformer | Capacity: 3150 kVA
FRONT VIEW
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
ELECTRIC SCHEMATIC DIAGRAM
SPECIFICATIONS
1. Model:S11-R-M-3150/0.48/0.208
2. Type:Dry-Type Transformer
3. Capacity:3150 kVA
4. Frequency:60 Hz
5. HV Voltage:0.48 kV
6. LV Voltage:0.208 kV
7. HV Current:3788.86A
8. LV Current:8743.53A
9. Vector Group:Delta-Wye (IEEE Std)
10. Impedance:7%
11. Insulation Level:A (105°C)
12. Temperature Rise:65K
13. No-Load Loss:37840W
14. Load Loss:94600W
15. No-Load Current:0.3%
16. Cooling Method:ONAN
17. Tap Changer:±5×2.5% 多档
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:2200×1400×2600mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line
Product Description
3150kVA, 3-phase oil-immersed transformer, 60Hz, primary 480V (HV 480V), secondary 208V (LV 208V), S11, insulation A, impedance 7%
Related Keywords
S11-R-M-3150/0.48/0.208 oil immersed power transformer3150kVA oil type distribution transformer0.48kV distribution network transformerS11-M series oil filled transformer low loss for urban grid
S11-R-M-3150/0.48/0.208 FAQ
What are the main application scenarios for S11-R-M-3150/0.48/0.208?
The S11-R-M-3150/0.48/0.208 (S11 series oil-immersed transformers) with rated capacity of 3150 kVA, HV side 0.48 kV, LV side 0.208 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of S11-R-M-3150/0.48/0.208?
Key specs: Capacity 3150 kVA, HV 0.48 kV, LV 0.208 kV, Frequency 60 Hz, Impedance 7%, Vector Group Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.
Can S11-R-M-3150/0.48/0.208 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.
Related Products in S11 Series
S11-R-M-10/10/0.4
Capacity: 10 kVA
Voltage: 10/0.4 kV
S11-R-M-10/6/0.4
Capacity: 10 kVA
Voltage: 6/0.4 kV
S11-R-M-10/35/0.4
Capacity: 10 kVA
Voltage: 35/0.4 kV
S11-R-M-10/10/0.48
Capacity: 10 kVA
Voltage: 10/0.48 kV
S11-R-M-10/10/0.22
Capacity: 10 kVA
Voltage: 10/0.22 kV
S11-R-M-10/0.48/0.208
Capacity: 10 kVA
Voltage: 0.48/0.208 kV
Interested in S11-R-M-3150/0.48/0.208?
Contact us for pricing, technical support, or custom requirements.