S13-M-25/10/0.48

S13-M Series25 kVA • 10/0.48 kV

Product Image & Parameters

25kVAS13-M

S13-M-25/10/0.48

S13-M Series

Capacity
25kVA
HV Voltage
10kV
LV Voltage
0.48kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: S13-M-25/10/0.48 | Type: Dry-Type Transformer | Capacity: 25 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N120mm150mm

SIDE VIEW

Ventilation90mm

TOP VIEW

1U1V1W2U2V2W2N120mm90mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDelta-Wye (IEEE Std)

SPECIFICATIONS

1. Model:S13-M-25/10/0.48
2. Type:Dry-Type Transformer
3. Capacity:25 kVA
4. Frequency:60 Hz
5. HV Voltage:10 kV
6. LV Voltage:0.48 kV
7. HV Current:1.44A
8. LV Current:30.07A
9. Vector Group:Delta-Wye (IEEE Std)
10. Impedance:4%
11. Insulation Level:A (105°C)
12. Temperature Rise:65K
13. No-Load Loss:800W
14. Load Loss:2000W
15. No-Load Current:0.9%
16. Cooling Method:ONAN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:800×600×1000mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

25kVA, 3-phase oil-immersed transformer, 60Hz, primary 10kV (HV 10kV), secondary 480V (LV 480V), S13, insulation A, impedance 4%

Related Keywords

S13-M-25/10/0.48 oil immersed power transformer25kVA oil type distribution transformer10kV distribution network transformerS13 energy-saving oil immersed transformer GB20052 compliant

S13-M-25/10/0.48 FAQ

What are the main application scenarios for S13-M-25/10/0.48?
The S13-M-25/10/0.48 (S13-M series oil-immersed transformers) with rated capacity of 25 kVA, HV side 10 kV, LV side 0.48 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of S13-M-25/10/0.48?
Key specs: Capacity 25 kVA, HV 10 kV, LV 0.48 kV, Frequency 60 Hz, Impedance 4%, Vector Group Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.
Can S13-M-25/10/0.48 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in S13-M-25/10/0.48?

Contact us for pricing, technical support, or custom requirements.