S13-M Series Oil-Immersed Transformers

162 Models available

S13-M Oil-Immersed Transformers

Images are for illustration purposes only

S13-M Series - Energy-Efficient Sealed Oil-Immersed Transformers (Level 13 Efficiency)

The S13-M series delivers enhanced energy efficiency with Level 13 rating, combining sealed construction with improved performance. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, mineral-oil insulation with 65 K temperature rise. Suitable for utility distribution networks, substations, solar farms, and industrial power systems.

Model Number Breakdown

13Performance level designation, corresponds to Level 13 energy efficiency standard
SThree-phase power transformer
MSealed construction, maintenance-free design

Key Features

  • Level 13 energy efficiency rating
  • Reduced energy losses
  • Sealed construction for reliability
  • Environmentally friendly design

Applications

  • Energy-efficient grids
  • Green power distribution
  • Modern utility networks
  • Sustainable infrastructure

TECHNICAL DRAWING

Model: S13-M-250/10/0.48 | Type: Oil-immersed transformer | Capacity: 250 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.180mm240mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDelta-Wye (IEEE Std)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level135mm

TOP VIEW

1U1V1W2U2V2W2N135mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity10–5000 kVA
HV Voltage (kV)10, 6, 35, 0.48
LV Voltage (kV)0.4, 0.48, 0.22, 0.208
Frequency (Hz)50, 60
Impedance (%)4, 4.5, 6, 7
CoolingONAN
EfficiencyClass 3
StandardIEC 60076, IEEE C57 / ANSI C84.1
ConnectionDyn11 (IEC), Delta-Wye (IEEE Std)
Insulation classA (105°C)
Allowed temperature rise65
Noise level≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)…
Tap Changer±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap, ±8×1.25% OLTC
No-load loss50–2780 W
Load loss390–38786 W
Select 2-3 models to compare
CompareModelCapacity (kVA)HV Voltage (kV)LV Voltage (kV)WeightDimensions
S13-M-10/10/0.410kVA100.4229 kg650×362×577 mm
S13-M-10/6/0.410kVA60.4229 kg650×362×577 mm
S13-M-10/35/0.410kVA350.4229 kg650×362×577 mm
S13-M-10/10/0.4810kVA100.48229 kg650×362×577 mm
S13-M-10/10/0.2210kVA100.22229 kg650×362×577 mm
S13-M-10/0.48/0.20810kVA0.480.208229 kg650×362×577 mm
S13-M-15/10/0.415kVA100.4247 kg675×382×596 mm
S13-M-15/6/0.415kVA60.4247 kg675×382×596 mm
S13-M-15/35/0.415kVA350.4247 kg675×382×596 mm
S13-M-15/10/0.4815kVA100.48247 kg675×382×596 mm
S13-M-15/10/0.2215kVA100.22247 kg675×382×596 mm
S13-M-15/0.48/0.20815kVA0.480.208247 kg675×382×596 mm
S13-M-20/10/0.420kVA100.4265 kg700×402×615 mm
S13-M-20/6/0.420kVA60.4265 kg700×402×615 mm
S13-M-20/35/0.420kVA350.4265 kg700×402×615 mm
S13-M-20/10/0.4820kVA100.48265 kg700×402×615 mm
S13-M-20/10/0.2220kVA100.22265 kg700×402×615 mm
S13-M-20/0.48/0.20820kVA0.480.208265 kg700×402×615 mm
S13-M-25/10/0.425kVA100.4288 kg784×443×634 mm
S13-M-25/6/0.425kVA60.4288 kg784×443×634 mm
S13-M-25/35/0.425kVA350.4288 kg784×443×634 mm
S13-M-25/10/0.4825kVA100.48288 kg784×443×634 mm
S13-M-25/10/0.2225kVA100.22288 kg784×443×634 mm
S13-M-25/0.48/0.20825kVA0.480.208288 kg784×443×634 mm
S13-M-30/10/0.430kVA100.4311 kg869×483×654 mm
S13-M-30/6/0.430kVA60.4311 kg869×483×654 mm
S13-M-30/35/0.430kVA350.4311 kg869×483×654 mm
S13-M-30/10/0.4830kVA100.48311 kg869×483×654 mm
S13-M-30/10/0.2230kVA100.22311 kg869×483×654 mm
S13-M-30/0.48/0.20830kVA0.480.208311 kg869×483×654 mm
S13-M-40/10/0.440kVA100.4370 kg884×491×673 mm
S13-M-40/6/0.440kVA60.4370 kg884×491×673 mm
S13-M-40/35/0.440kVA350.4370 kg884×491×673 mm
S13-M-40/10/0.4840kVA100.48370 kg884×491×673 mm
S13-M-40/10/0.2240kVA100.22370 kg884×491×673 mm
S13-M-40/0.48/0.20840kVA0.480.208370 kg884×491×673 mm
S13-M-50/10/0.450kVA100.4430 kg899×499×692 mm
S13-M-50/6/0.450kVA60.4430 kg899×499×692 mm
S13-M-50/35/0.450kVA350.4430 kg899×499×692 mm
S13-M-50/10/0.4850kVA100.48430 kg899×499×692 mm
S13-M-50/10/0.2250kVA100.22430 kg899×499×692 mm
S13-M-50/0.48/0.20850kVA0.480.208430 kg899×499×692 mm
S13-M-63/10/0.463kVA100.4480 kg944×519×727 mm
S13-M-63/6/0.463kVA60.4480 kg944×519×727 mm
S13-M-63/35/0.463kVA350.4480 kg944×519×727 mm
S13-M-63/10/0.4863kVA100.48480 kg944×519×727 mm
S13-M-63/10/0.2263kVA100.22480 kg944×519×727 mm
S13-M-63/0.48/0.20863kVA0.480.208480 kg944×519×727 mm
S13-M-80/10/0.480kVA100.4549 kg999×547×769 mm
S13-M-80/6/0.480kVA60.4549 kg999×547×769 mm
S13-M-80/35/0.480kVA350.4549 kg999×547×769 mm
S13-M-80/10/0.4880kVA100.48549 kg999×547×769 mm
S13-M-80/10/0.2280kVA100.22549 kg999×547×769 mm
S13-M-80/0.48/0.20880kVA0.480.208549 kg999×547×769 mm
S13-M-100/10/0.4100kVA100.4597 kg990×670×930 mm
S13-M-100/6/0.4100kVA60.4597 kg990×670×930 mm
S13-M-100/35/0.4100kVA350.4597 kg990×670×930 mm
S13-M-100/10/0.48100kVA100.48597 kg990×670×930 mm
S13-M-100/10/0.22100kVA100.22597 kg990×670×930 mm
S13-M-100/0.48/0.208100kVA0.480.208597 kg990×670×930 mm
S13-M-125/10/0.4125kVA100.4668 kg1079×579×846 mm
S13-M-125/6/0.4125kVA60.4668 kg1079×579×846 mm
S13-M-125/35/0.4125kVA350.4668 kg1079×579×846 mm
S13-M-125/10/0.48125kVA100.48668 kg1079×579×846 mm
S13-M-125/10/0.22125kVA100.22668 kg1079×579×846 mm
S13-M-125/0.48/0.208125kVA0.480.208668 kg1079×579×846 mm
S13-M-160/10/0.4160kVA100.4764 kg1045×685×965 mm
S13-M-160/6/0.4160kVA60.4764 kg1045×685×965 mm
S13-M-160/35/0.4160kVA350.4764 kg1045×685×965 mm
S13-M-160/10/0.48160kVA100.48764 kg1045×685×965 mm
S13-M-160/10/0.22160kVA100.22764 kg1045×685×965 mm
S13-M-160/0.48/0.208160kVA0.480.208764 kg1045×685×965 mm
S13-M-200/10/0.4200kVA100.4842 kg1120×750×1000 mm
S13-M-200/6/0.4200kVA60.4842 kg1120×750×1000 mm
S13-M-200/35/0.4200kVA350.4842 kg1120×750×1000 mm
S13-M-200/10/0.48200kVA100.48842 kg1120×750×1000 mm
S13-M-200/10/0.22200kVA100.22842 kg1120×750×1000 mm
S13-M-200/0.48/0.208200kVA0.480.208842 kg1120×750×1000 mm
S13-M-250/10/0.4250kVA100.4960 kg1189×829×1000 mm
S13-M-250/6/0.4250kVA60.4960 kg1189×829×1000 mm
S13-M-250/35/0.4250kVA350.4960 kg1189×829×1000 mm
S13-M-250/10/0.48250kVA100.48960 kg1189×829×1000 mm
S13-M-250/10/0.22250kVA100.22960 kg1189×829×1000 mm
S13-M-250/0.48/0.208250kVA0.480.208960 kg1189×829×1000 mm
S13-M-315/10/0.4315kVA100.41150 kg1350×930×1040 mm
S13-M-315/6/0.4315kVA60.41150 kg1350×930×1040 mm
S13-M-315/35/0.4315kVA350.41150 kg1350×930×1040 mm
S13-M-315/10/0.48315kVA100.481150 kg1350×930×1040 mm
S13-M-315/10/0.22315kVA100.221150 kg1350×930×1040 mm
S13-M-315/0.48/0.208315kVA0.480.2081150 kg1350×930×1040 mm
S13-M-400/10/0.4400kVA100.41349 kg1300×860×1090 mm
S13-M-400/6/0.4400kVA60.41349 kg1300×860×1090 mm
S13-M-400/35/0.4400kVA350.41349 kg1300×860×1090 mm
S13-M-400/10/0.48400kVA100.481349 kg1300×860×1090 mm
S13-M-400/10/0.22400kVA100.221349 kg1300×860×1090 mm
S13-M-400/0.48/0.208400kVA0.480.2081349 kg1300×860×1090 mm
S13-M-500/10/0.4500kVA100.41504 kg1390×960×1120 mm
S13-M-500/6/0.4500kVA60.41504 kg1390×960×1120 mm
S13-M-500/35/0.4500kVA350.41504 kg1390×960×1120 mm
S13-M-500/10/0.48500kVA100.481504 kg1390×960×1120 mm
S13-M-500/10/0.22500kVA100.221504 kg1390×960×1120 mm
S13-M-500/0.48/0.208500kVA0.480.2081504 kg1390×960×1120 mm
S13-M-630/10/0.4630kVA100.41818 kg1465×1020×1160 mm
S13-M-630/6/0.4630kVA60.41818 kg1465×1020×1160 mm
S13-M-630/35/0.4630kVA350.41818 kg1465×1020×1160 mm
S13-M-630/10/0.48630kVA100.481818 kg1465×1020×1160 mm
S13-M-630/10/0.22630kVA100.221818 kg1465×1020×1160 mm
S13-M-630/0.48/0.208630kVA0.480.2081818 kg1465×1020×1160 mm
S13-M-800/10/0.4800kVA100.42136 kg1525×1060×1200 mm
S13-M-800/6/0.4800kVA60.42136 kg1525×1060×1200 mm
S13-M-800/35/0.4800kVA350.42136 kg1525×1060×1200 mm
S13-M-800/10/0.48800kVA100.482136 kg1525×1060×1200 mm
S13-M-800/10/0.22800kVA100.222136 kg1525×1060×1200 mm
S13-M-800/0.48/0.208800kVA0.480.2082136 kg1525×1060×1200 mm
S13-M-1000/10/0.41000kVA100.42522 kg1750×1270×1230 mm
S13-M-1000/6/0.41000kVA60.42522 kg1750×1270×1230 mm
S13-M-1000/35/0.41000kVA350.42522 kg1750×1270×1230 mm
S13-M-1000/10/0.481000kVA100.482522 kg1750×1270×1230 mm
S13-M-1000/10/0.221000kVA100.222522 kg1750×1270×1230 mm
S13-M-1000/0.48/0.2081000kVA0.480.2082522 kg1750×1270×1230 mm
S13-M-1250/10/0.41250kVA100.42943 kg1720×1240×1300 mm
S13-M-1250/6/0.41250kVA60.42943 kg1720×1240×1300 mm
S13-M-1250/35/0.41250kVA350.42943 kg1720×1240×1300 mm
S13-M-1250/10/0.481250kVA100.482943 kg1720×1240×1300 mm
S13-M-1250/10/0.221250kVA100.222943 kg1720×1240×1300 mm
S13-M-1250/0.48/0.2081250kVA0.480.2082943 kg1720×1240×1300 mm
S13-M-1600/10/0.41600kVA100.44069.5 kg1879×1312×1492 mm
S13-M-1600/6/0.41600kVA60.44069.5 kg1879×1312×1492 mm
S13-M-1600/35/0.41600kVA350.44069.5 kg1879×1312×1492 mm
S13-M-1600/10/0.481600kVA100.484069.5 kg1879×1312×1492 mm
S13-M-1600/10/0.221600kVA100.224069.5 kg1879×1312×1492 mm
S13-M-1600/0.48/0.2081600kVA0.480.2084069.5 kg1879×1312×1492 mm
S13-M-2000/10/0.42000kVA100.44572.5 kg1999×1368×1538 mm
S13-M-2000/6/0.42000kVA60.44572.5 kg1999×1368×1538 mm
S13-M-2000/35/0.42000kVA350.44572.5 kg1999×1368×1538 mm
S13-M-2000/10/0.482000kVA100.484572.5 kg1999×1368×1538 mm
S13-M-2000/10/0.222000kVA100.224572.5 kg1999×1368×1538 mm
S13-M-2000/0.48/0.2082000kVA0.480.2084572.5 kg1999×1368×1538 mm
S13-M-2500/10/0.42500kVA100.45304 kg2179×1062×1515 mm
S13-M-2500/6/0.42500kVA60.45304 kg2179×1062×1515 mm
S13-M-2500/35/0.42500kVA350.45304 kg2179×1062×1515 mm
S13-M-2500/10/0.482500kVA100.485304 kg2179×1062×1515 mm
S13-M-2500/10/0.222500kVA100.225304 kg2179×1062×1515 mm
S13-M-2500/0.48/0.2082500kVA0.480.2085304 kg2179×1062×1515 mm
S13-M-3150/10/0.43150kVA100.46310 kg2299×1167×1615 mm
S13-M-3150/6/0.43150kVA60.46310 kg2299×1167×1615 mm
S13-M-3150/35/0.43150kVA350.46310 kg2299×1167×1615 mm
S13-M-3150/10/0.483150kVA100.486310 kg2299×1167×1615 mm
S13-M-3150/10/0.223150kVA100.226310 kg2299×1167×1615 mm
S13-M-3150/0.48/0.2083150kVA0.480.2086310 kg2299×1167×1615 mm
S13-M-4000/10/0.44000kVA100.47590 kg2498×1247×1730 mm
S13-M-4000/6/0.44000kVA60.47590 kg2498×1247×1730 mm
S13-M-4000/35/0.44000kVA350.47590 kg2498×1247×1730 mm
S13-M-4000/10/0.484000kVA100.487590 kg2498×1247×1730 mm
S13-M-4000/10/0.224000kVA100.227590 kg2498×1247×1730 mm
S13-M-4000/0.48/0.2084000kVA0.480.2087590 kg2498×1247×1730 mm
S13-M-5000/10/0.45000kVA100.49145 kg2698×1328×1845 mm
S13-M-5000/6/0.45000kVA60.49145 kg2698×1328×1845 mm
S13-M-5000/35/0.45000kVA350.49145 kg2698×1328×1845 mm
S13-M-5000/10/0.485000kVA100.489145 kg2698×1328×1845 mm
S13-M-5000/10/0.225000kVA100.229145 kg2698×1328×1845 mm
S13-M-5000/0.48/0.2085000kVA0.480.2089145 kg2698×1328×1845 mm

Selection Guide

1

Efficiency need

Choose S13-M over S11 when lower losses justify the higher initial cost, e.g. continuously loaded units.

2

Capacity & voltage

Standard selection: match supply voltage and total load.

3

Payback

For 24/7-loaded transformers, energy savings typically recover the premium within a few years.

- Frequently Asked Questions

How does S13-M improve efficiency?

Level 13 efficiency with lower no-load and load losses than S11, using higher-grade core steel.

Where is S13-M typically used?

Utility distribution networks and industrial plants where lower losses justify the higher initial cost.

Does S13-M use amorphous cores?

No, it uses low-loss silicon steel; amorphous is a separate (SBH15-M) product line.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
2 · Your price
EXW (FOB Qingdao)
$2,332
Range $2,146 ~ $2,5198%)
Price Breakdown
Base price (interpolation)$2,332
× Product factor×1.0000
× Country factor×1.0000
× Copper-linked factor×1.0000
+ Options / accessories$0
Shipping quoted separately per destination port.

Aluminum winding — no copper linkage

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.