S13-M Series - Energy-Efficient Sealed Oil-Immersed Transformers (Level 13 Efficiency)
The S13-M series delivers enhanced energy efficiency with Level 13 rating, combining sealed construction with improved performance. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, mineral-oil insulation with 65 K temperature rise. Suitable for utility distribution networks, substations, solar farms, and industrial power systems.
Model Number Breakdown
Key Features
- Level 13 energy efficiency rating
- Reduced energy losses
- Sealed construction for reliability
- Environmentally friendly design
Applications
- Energy-efficient grids
- Green power distribution
- Modern utility networks
- Sustainable infrastructure
TECHNICAL DRAWING
Model: S13-M-250/10/0.48 | Type: Oil-immersed transformer | Capacity: 250 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 10, 6, 35, 0.48 |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 6, 7 |
| Cooling | ONAN |
| Efficiency | Class 3 |
| Standard | IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | A (105°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)… |
| Tap Changer | ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap, ±8×1.25% OLTC |
| No-load loss | 50–2780 W |
| Load loss | 390–38786 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| S13-M-10/10/0.4 | 10kVA | 10 | 0.4 | 229 kg | 650×362×577 mm | |
| S13-M-10/6/0.4 | 10kVA | 6 | 0.4 | 229 kg | 650×362×577 mm | |
| S13-M-10/35/0.4 | 10kVA | 35 | 0.4 | 229 kg | 650×362×577 mm | |
| S13-M-10/10/0.48 | 10kVA | 10 | 0.48 | 229 kg | 650×362×577 mm | |
| S13-M-10/10/0.22 | 10kVA | 10 | 0.22 | 229 kg | 650×362×577 mm | |
| S13-M-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 229 kg | 650×362×577 mm | |
| S13-M-15/10/0.4 | 15kVA | 10 | 0.4 | 247 kg | 675×382×596 mm | |
| S13-M-15/6/0.4 | 15kVA | 6 | 0.4 | 247 kg | 675×382×596 mm | |
| S13-M-15/35/0.4 | 15kVA | 35 | 0.4 | 247 kg | 675×382×596 mm | |
| S13-M-15/10/0.48 | 15kVA | 10 | 0.48 | 247 kg | 675×382×596 mm | |
| S13-M-15/10/0.22 | 15kVA | 10 | 0.22 | 247 kg | 675×382×596 mm | |
| S13-M-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 247 kg | 675×382×596 mm | |
| S13-M-20/10/0.4 | 20kVA | 10 | 0.4 | 265 kg | 700×402×615 mm | |
| S13-M-20/6/0.4 | 20kVA | 6 | 0.4 | 265 kg | 700×402×615 mm | |
| S13-M-20/35/0.4 | 20kVA | 35 | 0.4 | 265 kg | 700×402×615 mm | |
| S13-M-20/10/0.48 | 20kVA | 10 | 0.48 | 265 kg | 700×402×615 mm | |
| S13-M-20/10/0.22 | 20kVA | 10 | 0.22 | 265 kg | 700×402×615 mm | |
| S13-M-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 265 kg | 700×402×615 mm | |
| S13-M-25/10/0.4 | 25kVA | 10 | 0.4 | 288 kg | 784×443×634 mm | |
| S13-M-25/6/0.4 | 25kVA | 6 | 0.4 | 288 kg | 784×443×634 mm | |
| S13-M-25/35/0.4 | 25kVA | 35 | 0.4 | 288 kg | 784×443×634 mm | |
| S13-M-25/10/0.48 | 25kVA | 10 | 0.48 | 288 kg | 784×443×634 mm | |
| S13-M-25/10/0.22 | 25kVA | 10 | 0.22 | 288 kg | 784×443×634 mm | |
| S13-M-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 288 kg | 784×443×634 mm | |
| S13-M-30/10/0.4 | 30kVA | 10 | 0.4 | 311 kg | 869×483×654 mm | |
| S13-M-30/6/0.4 | 30kVA | 6 | 0.4 | 311 kg | 869×483×654 mm | |
| S13-M-30/35/0.4 | 30kVA | 35 | 0.4 | 311 kg | 869×483×654 mm | |
| S13-M-30/10/0.48 | 30kVA | 10 | 0.48 | 311 kg | 869×483×654 mm | |
| S13-M-30/10/0.22 | 30kVA | 10 | 0.22 | 311 kg | 869×483×654 mm | |
| S13-M-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 311 kg | 869×483×654 mm | |
| S13-M-40/10/0.4 | 40kVA | 10 | 0.4 | 370 kg | 884×491×673 mm | |
| S13-M-40/6/0.4 | 40kVA | 6 | 0.4 | 370 kg | 884×491×673 mm | |
| S13-M-40/35/0.4 | 40kVA | 35 | 0.4 | 370 kg | 884×491×673 mm | |
| S13-M-40/10/0.48 | 40kVA | 10 | 0.48 | 370 kg | 884×491×673 mm | |
| S13-M-40/10/0.22 | 40kVA | 10 | 0.22 | 370 kg | 884×491×673 mm | |
| S13-M-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 370 kg | 884×491×673 mm | |
| S13-M-50/10/0.4 | 50kVA | 10 | 0.4 | 430 kg | 899×499×692 mm | |
| S13-M-50/6/0.4 | 50kVA | 6 | 0.4 | 430 kg | 899×499×692 mm | |
| S13-M-50/35/0.4 | 50kVA | 35 | 0.4 | 430 kg | 899×499×692 mm | |
| S13-M-50/10/0.48 | 50kVA | 10 | 0.48 | 430 kg | 899×499×692 mm | |
| S13-M-50/10/0.22 | 50kVA | 10 | 0.22 | 430 kg | 899×499×692 mm | |
| S13-M-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 430 kg | 899×499×692 mm | |
| S13-M-63/10/0.4 | 63kVA | 10 | 0.4 | 480 kg | 944×519×727 mm | |
| S13-M-63/6/0.4 | 63kVA | 6 | 0.4 | 480 kg | 944×519×727 mm | |
| S13-M-63/35/0.4 | 63kVA | 35 | 0.4 | 480 kg | 944×519×727 mm | |
| S13-M-63/10/0.48 | 63kVA | 10 | 0.48 | 480 kg | 944×519×727 mm | |
| S13-M-63/10/0.22 | 63kVA | 10 | 0.22 | 480 kg | 944×519×727 mm | |
| S13-M-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 480 kg | 944×519×727 mm | |
| S13-M-80/10/0.4 | 80kVA | 10 | 0.4 | 549 kg | 999×547×769 mm | |
| S13-M-80/6/0.4 | 80kVA | 6 | 0.4 | 549 kg | 999×547×769 mm | |
| S13-M-80/35/0.4 | 80kVA | 35 | 0.4 | 549 kg | 999×547×769 mm | |
| S13-M-80/10/0.48 | 80kVA | 10 | 0.48 | 549 kg | 999×547×769 mm | |
| S13-M-80/10/0.22 | 80kVA | 10 | 0.22 | 549 kg | 999×547×769 mm | |
| S13-M-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 549 kg | 999×547×769 mm | |
| S13-M-100/10/0.4 | 100kVA | 10 | 0.4 | 597 kg | 990×670×930 mm | |
| S13-M-100/6/0.4 | 100kVA | 6 | 0.4 | 597 kg | 990×670×930 mm | |
| S13-M-100/35/0.4 | 100kVA | 35 | 0.4 | 597 kg | 990×670×930 mm | |
| S13-M-100/10/0.48 | 100kVA | 10 | 0.48 | 597 kg | 990×670×930 mm | |
| S13-M-100/10/0.22 | 100kVA | 10 | 0.22 | 597 kg | 990×670×930 mm | |
| S13-M-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 597 kg | 990×670×930 mm | |
| S13-M-125/10/0.4 | 125kVA | 10 | 0.4 | 668 kg | 1079×579×846 mm | |
| S13-M-125/6/0.4 | 125kVA | 6 | 0.4 | 668 kg | 1079×579×846 mm | |
| S13-M-125/35/0.4 | 125kVA | 35 | 0.4 | 668 kg | 1079×579×846 mm | |
| S13-M-125/10/0.48 | 125kVA | 10 | 0.48 | 668 kg | 1079×579×846 mm | |
| S13-M-125/10/0.22 | 125kVA | 10 | 0.22 | 668 kg | 1079×579×846 mm | |
| S13-M-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 668 kg | 1079×579×846 mm | |
| S13-M-160/10/0.4 | 160kVA | 10 | 0.4 | 764 kg | 1045×685×965 mm | |
| S13-M-160/6/0.4 | 160kVA | 6 | 0.4 | 764 kg | 1045×685×965 mm | |
| S13-M-160/35/0.4 | 160kVA | 35 | 0.4 | 764 kg | 1045×685×965 mm | |
| S13-M-160/10/0.48 | 160kVA | 10 | 0.48 | 764 kg | 1045×685×965 mm | |
| S13-M-160/10/0.22 | 160kVA | 10 | 0.22 | 764 kg | 1045×685×965 mm | |
| S13-M-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 764 kg | 1045×685×965 mm | |
| S13-M-200/10/0.4 | 200kVA | 10 | 0.4 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/6/0.4 | 200kVA | 6 | 0.4 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/35/0.4 | 200kVA | 35 | 0.4 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/10/0.48 | 200kVA | 10 | 0.48 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/10/0.22 | 200kVA | 10 | 0.22 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 842 kg | 1120×750×1000 mm | |
| S13-M-250/10/0.4 | 250kVA | 10 | 0.4 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/6/0.4 | 250kVA | 6 | 0.4 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/35/0.4 | 250kVA | 35 | 0.4 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/10/0.48 | 250kVA | 10 | 0.48 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/10/0.22 | 250kVA | 10 | 0.22 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 960 kg | 1189×829×1000 mm | |
| S13-M-315/10/0.4 | 315kVA | 10 | 0.4 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/6/0.4 | 315kVA | 6 | 0.4 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/35/0.4 | 315kVA | 35 | 0.4 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/10/0.48 | 315kVA | 10 | 0.48 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/10/0.22 | 315kVA | 10 | 0.22 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1150 kg | 1350×930×1040 mm | |
| S13-M-400/10/0.4 | 400kVA | 10 | 0.4 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/6/0.4 | 400kVA | 6 | 0.4 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/35/0.4 | 400kVA | 35 | 0.4 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/10/0.48 | 400kVA | 10 | 0.48 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/10/0.22 | 400kVA | 10 | 0.22 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1349 kg | 1300×860×1090 mm | |
| S13-M-500/10/0.4 | 500kVA | 10 | 0.4 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/6/0.4 | 500kVA | 6 | 0.4 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/35/0.4 | 500kVA | 35 | 0.4 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/10/0.48 | 500kVA | 10 | 0.48 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/10/0.22 | 500kVA | 10 | 0.22 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1504 kg | 1390×960×1120 mm | |
| S13-M-630/10/0.4 | 630kVA | 10 | 0.4 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/6/0.4 | 630kVA | 6 | 0.4 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/35/0.4 | 630kVA | 35 | 0.4 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/10/0.48 | 630kVA | 10 | 0.48 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/10/0.22 | 630kVA | 10 | 0.22 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-800/10/0.4 | 800kVA | 10 | 0.4 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/6/0.4 | 800kVA | 6 | 0.4 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/35/0.4 | 800kVA | 35 | 0.4 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/10/0.48 | 800kVA | 10 | 0.48 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/10/0.22 | 800kVA | 10 | 0.22 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1250/10/0.4 | 1250kVA | 10 | 0.4 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/6/0.4 | 1250kVA | 6 | 0.4 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/35/0.4 | 1250kVA | 35 | 0.4 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/10/0.48 | 1250kVA | 10 | 0.48 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/10/0.22 | 1250kVA | 10 | 0.22 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1600/10/0.4 | 1600kVA | 10 | 0.4 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/6/0.4 | 1600kVA | 6 | 0.4 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/35/0.4 | 1600kVA | 35 | 0.4 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/10/0.48 | 1600kVA | 10 | 0.48 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/10/0.22 | 1600kVA | 10 | 0.22 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-2000/10/0.4 | 2000kVA | 10 | 0.4 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/6/0.4 | 2000kVA | 6 | 0.4 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/35/0.4 | 2000kVA | 35 | 0.4 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/10/0.48 | 2000kVA | 10 | 0.48 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/10/0.22 | 2000kVA | 10 | 0.22 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2500/10/0.4 | 2500kVA | 10 | 0.4 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/6/0.4 | 2500kVA | 6 | 0.4 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/35/0.4 | 2500kVA | 35 | 0.4 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/10/0.48 | 2500kVA | 10 | 0.48 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/10/0.22 | 2500kVA | 10 | 0.22 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-3150/10/0.4 | 3150kVA | 10 | 0.4 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/6/0.4 | 3150kVA | 6 | 0.4 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/35/0.4 | 3150kVA | 35 | 0.4 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/10/0.48 | 3150kVA | 10 | 0.48 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/10/0.22 | 3150kVA | 10 | 0.22 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-4000/10/0.4 | 4000kVA | 10 | 0.4 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/6/0.4 | 4000kVA | 6 | 0.4 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/35/0.4 | 4000kVA | 35 | 0.4 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/10/0.48 | 4000kVA | 10 | 0.48 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/10/0.22 | 4000kVA | 10 | 0.22 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-5000/10/0.4 | 5000kVA | 10 | 0.4 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/6/0.4 | 5000kVA | 6 | 0.4 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/35/0.4 | 5000kVA | 35 | 0.4 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/10/0.48 | 5000kVA | 10 | 0.48 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/10/0.22 | 5000kVA | 10 | 0.22 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 9145 kg | 2698×1328×1845 mm |
Selection Guide
Efficiency need
Choose S13-M over S11 when lower losses justify the higher initial cost, e.g. continuously loaded units.
Capacity & voltage
Standard selection: match supply voltage and total load.
Payback
For 24/7-loaded transformers, energy savings typically recover the premium within a few years.
- Frequently Asked Questions
How does S13-M improve efficiency?
Level 13 efficiency with lower no-load and load losses than S11, using higher-grade core steel.
Where is S13-M typically used?
Utility distribution networks and industrial plants where lower losses justify the higher initial cost.
Does S13-M use amorphous cores?
No, it uses low-loss silicon steel; amorphous is a separate (SBH15-M) product line.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
| Base price (interpolation) | $2,332 |
| × Product factor | ×1.0000 |
| × Country factor | ×1.0000 |
| × Copper-linked factor | ×1.0000 |
| + Options / accessories | $0 |
Aluminum winding — no copper linkage
Reference prices are for estimation only and do not constitute a formal offer.