Product Search
Find the right transformer for your needs

Images are for illustration purposes only
S13-M Series - Energy-Efficient Sealed Oil-Immersed Transformers (Level 13 Efficiency)
The S13-M series delivers enhanced energy efficiency with Level 13 rating, combining sealed construction with improved performance. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, mineral-oil insulation with 65 K temperature rise. Suitable for utility distribution networks, substations, solar farms, and industrial power systems.
Model Number Breakdown
Key Features
- Level 13 energy efficiency rating
- Reduced energy losses
- Sealed construction for reliability
- Environmentally friendly design
Applications
- Energy-efficient grids
- Green power distribution
- Modern utility networks
- Sustainable infrastructure
TECHNICAL DRAWING
Model: S13-M-250/10/0.48 | Type: Oil-immersed transformer | Capacity: 250 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 10, 6, 35, 0.48 |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 6, 7 |
| Cooling | ONAN |
| Efficiency | Class 3 |
| Standard | IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | A (105°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)… |
| Tap Changer | ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap |
| No-load loss | 50–2780 W |
| Load loss | 390–38786 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| S13-M-10/10/0.4 | 10kVA | 10 | 0.4 | 229 kg | 650×362×577 mm | |
| S13-M-10/6/0.4 | 10kVA | 6 | 0.4 | 229 kg | 650×362×577 mm | |
| S13-M-10/35/0.4 | 10kVA | 35 | 0.4 | 229 kg | 650×362×577 mm | |
| S13-M-10/10/0.48 | 10kVA | 10 | 0.48 | 229 kg | 650×362×577 mm | |
| S13-M-10/10/0.22 | 10kVA | 10 | 0.22 | 229 kg | 650×362×577 mm | |
| S13-M-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 229 kg | 650×362×577 mm | |
| S13-M-15/10/0.4 | 15kVA | 10 | 0.4 | 247 kg | 675×382×596 mm | |
| S13-M-15/6/0.4 | 15kVA | 6 | 0.4 | 247 kg | 675×382×596 mm | |
| S13-M-15/35/0.4 | 15kVA | 35 | 0.4 | 247 kg | 675×382×596 mm | |
| S13-M-15/10/0.48 | 15kVA | 10 | 0.48 | 247 kg | 675×382×596 mm | |
| S13-M-15/10/0.22 | 15kVA | 10 | 0.22 | 247 kg | 675×382×596 mm | |
| S13-M-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 247 kg | 675×382×596 mm | |
| S13-M-20/10/0.4 | 20kVA | 10 | 0.4 | 265 kg | 700×402×615 mm | |
| S13-M-20/6/0.4 | 20kVA | 6 | 0.4 | 265 kg | 700×402×615 mm | |
| S13-M-20/35/0.4 | 20kVA | 35 | 0.4 | 265 kg | 700×402×615 mm | |
| S13-M-20/10/0.48 | 20kVA | 10 | 0.48 | 265 kg | 700×402×615 mm | |
| S13-M-20/10/0.22 | 20kVA | 10 | 0.22 | 265 kg | 700×402×615 mm | |
| S13-M-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 265 kg | 700×402×615 mm | |
| S13-M-25/10/0.4 | 25kVA | 10 | 0.4 | 288 kg | 784×443×634 mm | |
| S13-M-25/6/0.4 | 25kVA | 6 | 0.4 | 288 kg | 784×443×634 mm | |
| S13-M-25/35/0.4 | 25kVA | 35 | 0.4 | 288 kg | 784×443×634 mm | |
| S13-M-25/10/0.48 | 25kVA | 10 | 0.48 | 288 kg | 784×443×634 mm | |
| S13-M-25/10/0.22 | 25kVA | 10 | 0.22 | 288 kg | 784×443×634 mm | |
| S13-M-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 288 kg | 784×443×634 mm | |
| S13-M-30/10/0.4 | 30kVA | 10 | 0.4 | 311 kg | 869×483×654 mm | |
| S13-M-30/6/0.4 | 30kVA | 6 | 0.4 | 311 kg | 869×483×654 mm | |
| S13-M-30/35/0.4 | 30kVA | 35 | 0.4 | 311 kg | 869×483×654 mm | |
| S13-M-30/10/0.48 | 30kVA | 10 | 0.48 | 311 kg | 869×483×654 mm | |
| S13-M-30/10/0.22 | 30kVA | 10 | 0.22 | 311 kg | 869×483×654 mm | |
| S13-M-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 311 kg | 869×483×654 mm | |
| S13-M-40/10/0.4 | 40kVA | 10 | 0.4 | 370 kg | 884×491×673 mm | |
| S13-M-40/6/0.4 | 40kVA | 6 | 0.4 | 370 kg | 884×491×673 mm | |
| S13-M-40/35/0.4 | 40kVA | 35 | 0.4 | 370 kg | 884×491×673 mm | |
| S13-M-40/10/0.48 | 40kVA | 10 | 0.48 | 370 kg | 884×491×673 mm | |
| S13-M-40/10/0.22 | 40kVA | 10 | 0.22 | 370 kg | 884×491×673 mm | |
| S13-M-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 370 kg | 884×491×673 mm | |
| S13-M-50/10/0.4 | 50kVA | 10 | 0.4 | 430 kg | 899×499×692 mm | |
| S13-M-50/6/0.4 | 50kVA | 6 | 0.4 | 430 kg | 899×499×692 mm | |
| S13-M-50/35/0.4 | 50kVA | 35 | 0.4 | 430 kg | 899×499×692 mm | |
| S13-M-50/10/0.48 | 50kVA | 10 | 0.48 | 430 kg | 899×499×692 mm | |
| S13-M-50/10/0.22 | 50kVA | 10 | 0.22 | 430 kg | 899×499×692 mm | |
| S13-M-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 430 kg | 899×499×692 mm | |
| S13-M-63/10/0.4 | 63kVA | 10 | 0.4 | 480 kg | 944×519×727 mm | |
| S13-M-63/6/0.4 | 63kVA | 6 | 0.4 | 480 kg | 944×519×727 mm | |
| S13-M-63/35/0.4 | 63kVA | 35 | 0.4 | 480 kg | 944×519×727 mm | |
| S13-M-63/10/0.48 | 63kVA | 10 | 0.48 | 480 kg | 944×519×727 mm | |
| S13-M-63/10/0.22 | 63kVA | 10 | 0.22 | 480 kg | 944×519×727 mm | |
| S13-M-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 480 kg | 944×519×727 mm | |
| S13-M-80/10/0.4 | 80kVA | 10 | 0.4 | 549 kg | 999×547×769 mm | |
| S13-M-80/6/0.4 | 80kVA | 6 | 0.4 | 549 kg | 999×547×769 mm | |
| S13-M-80/35/0.4 | 80kVA | 35 | 0.4 | 549 kg | 999×547×769 mm | |
| S13-M-80/10/0.48 | 80kVA | 10 | 0.48 | 549 kg | 999×547×769 mm | |
| S13-M-80/10/0.22 | 80kVA | 10 | 0.22 | 549 kg | 999×547×769 mm | |
| S13-M-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 549 kg | 999×547×769 mm | |
| S13-M-100/10/0.4 | 100kVA | 10 | 0.4 | 597 kg | 990×670×930 mm | |
| S13-M-100/6/0.4 | 100kVA | 6 | 0.4 | 597 kg | 990×670×930 mm | |
| S13-M-100/35/0.4 | 100kVA | 35 | 0.4 | 597 kg | 990×670×930 mm | |
| S13-M-100/10/0.48 | 100kVA | 10 | 0.48 | 597 kg | 990×670×930 mm | |
| S13-M-100/10/0.22 | 100kVA | 10 | 0.22 | 597 kg | 990×670×930 mm | |
| S13-M-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 597 kg | 990×670×930 mm | |
| S13-M-125/10/0.4 | 125kVA | 10 | 0.4 | 668 kg | 1079×579×846 mm | |
| S13-M-125/6/0.4 | 125kVA | 6 | 0.4 | 668 kg | 1079×579×846 mm | |
| S13-M-125/35/0.4 | 125kVA | 35 | 0.4 | 668 kg | 1079×579×846 mm | |
| S13-M-125/10/0.48 | 125kVA | 10 | 0.48 | 668 kg | 1079×579×846 mm | |
| S13-M-125/10/0.22 | 125kVA | 10 | 0.22 | 668 kg | 1079×579×846 mm | |
| S13-M-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 668 kg | 1079×579×846 mm | |
| S13-M-160/10/0.4 | 160kVA | 10 | 0.4 | 764 kg | 1045×685×965 mm | |
| S13-M-160/6/0.4 | 160kVA | 6 | 0.4 | 764 kg | 1045×685×965 mm | |
| S13-M-160/35/0.4 | 160kVA | 35 | 0.4 | 764 kg | 1045×685×965 mm | |
| S13-M-160/10/0.48 | 160kVA | 10 | 0.48 | 764 kg | 1045×685×965 mm | |
| S13-M-160/10/0.22 | 160kVA | 10 | 0.22 | 764 kg | 1045×685×965 mm | |
| S13-M-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 764 kg | 1045×685×965 mm | |
| S13-M-200/10/0.4 | 200kVA | 10 | 0.4 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/6/0.4 | 200kVA | 6 | 0.4 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/35/0.4 | 200kVA | 35 | 0.4 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/10/0.48 | 200kVA | 10 | 0.48 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/10/0.22 | 200kVA | 10 | 0.22 | 842 kg | 1120×750×1000 mm | |
| S13-M-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 842 kg | 1120×750×1000 mm | |
| S13-M-250/10/0.4 | 250kVA | 10 | 0.4 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/6/0.4 | 250kVA | 6 | 0.4 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/35/0.4 | 250kVA | 35 | 0.4 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/10/0.48 | 250kVA | 10 | 0.48 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/10/0.22 | 250kVA | 10 | 0.22 | 960 kg | 1189×829×1000 mm | |
| S13-M-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 960 kg | 1189×829×1000 mm | |
| S13-M-315/10/0.4 | 315kVA | 10 | 0.4 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/6/0.4 | 315kVA | 6 | 0.4 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/35/0.4 | 315kVA | 35 | 0.4 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/10/0.48 | 315kVA | 10 | 0.48 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/10/0.22 | 315kVA | 10 | 0.22 | 1150 kg | 1350×930×1040 mm | |
| S13-M-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1150 kg | 1350×930×1040 mm | |
| S13-M-400/10/0.4 | 400kVA | 10 | 0.4 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/6/0.4 | 400kVA | 6 | 0.4 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/35/0.4 | 400kVA | 35 | 0.4 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/10/0.48 | 400kVA | 10 | 0.48 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/10/0.22 | 400kVA | 10 | 0.22 | 1349 kg | 1300×860×1090 mm | |
| S13-M-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1349 kg | 1300×860×1090 mm | |
| S13-M-500/10/0.4 | 500kVA | 10 | 0.4 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/6/0.4 | 500kVA | 6 | 0.4 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/35/0.4 | 500kVA | 35 | 0.4 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/10/0.48 | 500kVA | 10 | 0.48 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/10/0.22 | 500kVA | 10 | 0.22 | 1504 kg | 1390×960×1120 mm | |
| S13-M-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1504 kg | 1390×960×1120 mm | |
| S13-M-630/10/0.4 | 630kVA | 10 | 0.4 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/6/0.4 | 630kVA | 6 | 0.4 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/35/0.4 | 630kVA | 35 | 0.4 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/10/0.48 | 630kVA | 10 | 0.48 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/10/0.22 | 630kVA | 10 | 0.22 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 1818 kg | 1465×1020×1160 mm | |
| S13-M-800/10/0.4 | 800kVA | 10 | 0.4 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/6/0.4 | 800kVA | 6 | 0.4 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/35/0.4 | 800kVA | 35 | 0.4 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/10/0.48 | 800kVA | 10 | 0.48 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/10/0.22 | 800kVA | 10 | 0.22 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 2136 kg | 1525×1060×1200 mm | |
| S13-M-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2522 kg | 1750×1270×1230 mm | |
| S13-M-1250/10/0.4 | 1250kVA | 10 | 0.4 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/6/0.4 | 1250kVA | 6 | 0.4 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/35/0.4 | 1250kVA | 35 | 0.4 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/10/0.48 | 1250kVA | 10 | 0.48 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/10/0.22 | 1250kVA | 10 | 0.22 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 2943 kg | 1720×1240×1300 mm | |
| S13-M-1600/10/0.4 | 1600kVA | 10 | 0.4 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/6/0.4 | 1600kVA | 6 | 0.4 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/35/0.4 | 1600kVA | 35 | 0.4 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/10/0.48 | 1600kVA | 10 | 0.48 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/10/0.22 | 1600kVA | 10 | 0.22 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 4069.5 kg | 1879×1312×1492 mm | |
| S13-M-2000/10/0.4 | 2000kVA | 10 | 0.4 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/6/0.4 | 2000kVA | 6 | 0.4 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/35/0.4 | 2000kVA | 35 | 0.4 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/10/0.48 | 2000kVA | 10 | 0.48 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/10/0.22 | 2000kVA | 10 | 0.22 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 4572.5 kg | 1999×1368×1538 mm | |
| S13-M-2500/10/0.4 | 2500kVA | 10 | 0.4 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/6/0.4 | 2500kVA | 6 | 0.4 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/35/0.4 | 2500kVA | 35 | 0.4 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/10/0.48 | 2500kVA | 10 | 0.48 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/10/0.22 | 2500kVA | 10 | 0.22 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 5304 kg | 2179×1062×1515 mm | |
| S13-M-3150/10/0.4 | 3150kVA | 10 | 0.4 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/6/0.4 | 3150kVA | 6 | 0.4 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/35/0.4 | 3150kVA | 35 | 0.4 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/10/0.48 | 3150kVA | 10 | 0.48 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/10/0.22 | 3150kVA | 10 | 0.22 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 6310 kg | 2299×1167×1615 mm | |
| S13-M-4000/10/0.4 | 4000kVA | 10 | 0.4 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/6/0.4 | 4000kVA | 6 | 0.4 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/35/0.4 | 4000kVA | 35 | 0.4 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/10/0.48 | 4000kVA | 10 | 0.48 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/10/0.22 | 4000kVA | 10 | 0.22 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 7590 kg | 2498×1247×1730 mm | |
| S13-M-5000/10/0.4 | 5000kVA | 10 | 0.4 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/6/0.4 | 5000kVA | 6 | 0.4 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/35/0.4 | 5000kVA | 35 | 0.4 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/10/0.48 | 5000kVA | 10 | 0.48 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/10/0.22 | 5000kVA | 10 | 0.22 | 9145 kg | 2698×1328×1845 mm | |
| S13-M-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 9145 kg | 2698×1328×1845 mm |
Selection Guide
Efficiency need
Choose S13-M over S11 when lower losses justify the higher initial cost, e.g. continuously loaded units.
Capacity & voltage
Standard selection: match supply voltage and total load.
Payback
For 24/7-loaded transformers, energy savings typically recover the premium within a few years.
- Frequently Asked Questions
How does S13-M improve efficiency?
Level 13 efficiency with lower no-load and load losses than S11, using higher-grade core steel.
Where is S13-M typically used?
Utility distribution networks and industrial plants where lower losses justify the higher initial cost.
Does S13-M use amorphous cores?
No, it uses low-loss silicon steel; amorphous is a separate (SBH15-M) product line.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(6)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators