BK-100/0.4/0.22

BK Series100 kVA • 0.4/0.22 kV

Product Image & Parameters

100kVABK

BK-100/0.4/0.22

BK Series

Capacity
100kVA
HV Voltage
0.4kV
LV Voltage
0.22kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: BK-100/0.4/0.22 | Type: Dry-Type Transformer | Capacity: 100 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N135mm180mm

SIDE VIEW

Ventilation105mm

TOP VIEW

1U1V1W2U2V2W2N135mm105mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDyn11 (IEC)

SPECIFICATIONS

1. Model:BK-100/0.4/0.22
2. Type:Dry-Type Transformer
3. Capacity:100 kVA
4. Frequency:50 Hz
5. HV Voltage:0.4 kV
6. LV Voltage:0.22 kV
7. HV Current:144.34A
8. LV Current:262.43A
9. Vector Group:Dyn11 (IEC)
10. Impedance:4%
11. Insulation Level:H (180°C)
12. Temperature Rise:65K
13. No-Load Loss:3938W
14. Load Loss:9845W
15. No-Load Current:1.3%
16. Cooling Method:AN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEC 60076
19. Dimensions:900×700×1200mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

100kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 400V (HV 400V), secondary 220V (LV 220V), Standard, insulation H, impedance 4%

Related Keywords

BK-100/0.4/0.22 isolation control transformer100kVA control transformerprimary 0.4kV secondary 0.22kVBK single phase control transformer for machine tool equipment

BK-100/0.4/0.22 FAQ

What are the main application scenarios for BK-100/0.4/0.22?
The BK-100/0.4/0.22 (BK series special/isolation/control transformers) with rated capacity of 100 kVA, HV side 0.4 kV, LV side 0.22 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of BK-100/0.4/0.22?
Key specs: Capacity 100 kVA, HV 0.4 kV, LV 0.22 kV, Frequency 50 Hz, Impedance 4%, Vector Group Dyn11 (IEC), Cooling AN, Standard IEC 60076.
Can BK-100/0.4/0.22 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in BK-100/0.4/0.22?

Contact us for pricing, technical support, or custom requirements.