| Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Description |
|---|---|---|---|---|
| BK-0.1/0.48/0.208 | 0.1 | 0.48 | 0.208 | 0.10kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 208V (LV 208V), Standard, insulation H, impedance 4% |
| BK-0.1/0.48/0.24 | 0.1 | 0.48 | 0.24 | 0.10kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 240V (LV 240V), Standard, insulation H, impedance 4% |
| BK-0.1/0.22/0.12 | 0.1 | 0.22 | 0.12 | 0.10kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 220V (HV 220V), secondary 120V (LV 120V), Standard, insulation H, impedance 4% |
| BK-0.1/0.38/0.22 | 0.1 | 0.38 | 0.22 | 0.10kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 380V (HV 380V), secondary 220V (LV 220V), Standard, insulation H, impedance 4% |
| BK-0.1/10/0.4 | 0.1 | 10 | 0.4 | 0.10kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), Standard, insulation H, impedance 4% |
| BK-0.1/6/0.4 | 0.1 | 6 | 0.4 | 0.10kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 6kV (HV 6kV), secondary 400V (LV 400V), Standard, insulation H, impedance 4% |
| BK-0.1/0.66/0.38 | 0.1 | 0.66 | 0.38 | 0.10kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 660V (HV 660V), secondary 380V (LV 380V), Standard, insulation H, impedance 4% |
| BK-0.1/0.4/0.22 | 0.1 | 0.4 | 0.22 | 0.10kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 400V (HV 400V), secondary 220V (LV 220V), Standard, insulation H, impedance 4% |
| BK-0.2/0.48/0.208 | 0.2 | 0.48 | 0.208 | 0.20kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 208V (LV 208V), Standard, insulation H, impedance 4% |
| BK-0.2/0.48/0.24 | 0.2 | 0.48 | 0.24 | 0.20kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 240V (LV 240V), Standard, insulation H, impedance 4% |
| BK-0.2/0.22/0.12 | 0.2 | 0.22 | 0.12 | 0.20kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 220V (HV 220V), secondary 120V (LV 120V), Standard, insulation H, impedance 4% |
| BK-0.2/0.38/0.22 | 0.2 | 0.38 | 0.22 | 0.20kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 380V (HV 380V), secondary 220V (LV 220V), Standard, insulation H, impedance 4% |
| BK-0.2/10/0.4 | 0.2 | 10 | 0.4 | 0.20kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 10kV (HV 10kV), secondary 400V (LV 400V), Standard, insulation H, impedance 4% |
| BK-0.2/6/0.4 | 0.2 | 6 | 0.4 | 0.20kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 6kV (HV 6kV), secondary 400V (LV 400V), Standard, insulation H, impedance 4% |
| BK-0.2/0.66/0.38 | 0.2 | 0.66 | 0.38 | 0.20kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 660V (HV 660V), secondary 380V (LV 380V), Standard, insulation H, impedance 4% |
| BK-0.2/0.4/0.22 | 0.2 | 0.4 | 0.22 | 0.20kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 400V (HV 400V), secondary 220V (LV 220V), Standard, insulation H, impedance 4% |
| BK-0.3/0.48/0.208 | 0.3 | 0.48 | 0.208 | 0.30kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 208V (LV 208V), Standard, insulation H, impedance 4% |
| BK-0.3/0.48/0.24 | 0.3 | 0.48 | 0.24 | 0.30kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 240V (LV 240V), Standard, insulation H, impedance 4% |
| BK-0.3/0.22/0.12 | 0.3 | 0.22 | 0.12 | 0.30kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 220V (HV 220V), secondary 120V (LV 120V), Standard, insulation H, impedance 4% |
| BK-0.3/0.38/0.22 | 0.3 | 0.38 | 0.22 | 0.30kVA, 3-phase isolation, dry-type transformer, 50Hz, primary 380V (HV 380V), secondary 220V (LV 220V), Standard, insulation H, impedance 4% |