BKC-100/0.48/0.208

BKC Series100 kVA • 0.48/0.208 kV

Product Image & Parameters

100kVABKC

BKC-100/0.48/0.208

BKC Series

Capacity
100kVA
HV Voltage
0.48kV
LV Voltage
0.208kV
Efficiency
2Level
Amorphous Alloy CoreEnergy SavingLow Loss

TECHNICAL DRAWING

Model: BKC-100/0.48/0.208 | Type: Dry-Type Transformer | Capacity: 100 kVA

FRONT VIEW

HVLV1U1V1W2U2V2W2N135mm180mm

SIDE VIEW

Ventilation105mm

TOP VIEW

1U1V1W2U2V2W2N135mm105mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal Block ConfigurationTin-Plated Copper Busbar

ELECTRIC SCHEMATIC DIAGRAM

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NVector GroupDelta-Wye (IEEE Std)

SPECIFICATIONS

1. Model:BKC-100/0.48/0.208
2. Type:Dry-Type Transformer
3. Capacity:100 kVA
4. Frequency:60 Hz
5. HV Voltage:0.48 kV
6. LV Voltage:0.208 kV
7. HV Current:120.28A
8. LV Current:277.57A
9. Vector Group:Delta-Wye (IEEE Std)
10. Impedance:4%
11. Insulation Level:H (180°C)
12. Temperature Rise:65K
13. No-Load Loss:3938W
14. Load Loss:9845W
15. No-Load Current:1.3%
16. Cooling Method:AN
17. Tap Changer:±2×2.5% 多档
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:900×700×1200mm
20. Weight:-
LEGEND:
Iron Core
HV Winding/Bushing
LV Winding/Bushing
Dimension Line

Product Description

100kVA, 3-phase isolation, dry-type transformer, 60Hz, primary 480V (HV 480V), secondary 208V (LV 208V), Standard, insulation H, impedance 4%

Related Keywords

BKC-100/0.48/0.208 isolation control transformer100kVA control transformerprimary 0.48kV secondary 0.208kVBKC mining flameproof control transformer for coal mine

BKC-100/0.48/0.208 FAQ

What are the main application scenarios for BKC-100/0.48/0.208?
The BKC-100/0.48/0.208 (BKC series special/isolation/control transformers) with rated capacity of 100 kVA, HV side 0.48 kV, LV side 0.208 kV, is widely used in industrial distribution, commercial buildings, and power systems. It can be flexibly configured according to actual project requirements.
What are the technical specifications of BKC-100/0.48/0.208?
Key specs: Capacity 100 kVA, HV 0.48 kV, LV 0.208 kV, Frequency 60 Hz, Impedance 4%, Vector Group Delta-Wye (IEEE Std), Cooling AN, Standard IEEE C57 / ANSI C84.1.
Can BKC-100/0.48/0.208 be customized?
Yes. QDTB® offers comprehensive OEM/ODM customization. Parameters such as capacity, voltage ratio, cooling method, vector group, and protection class can be adjusted. 23+ years of manufacturing experience ensures consistent quality.
How to get a quote and technical documentation?
Contact us via the "Send Inquiry" button below, or reach our sales team at Alice@qdtb-transformer.com / +86 13698683193. We will provide detailed quotations and technical documentation within 24 hours.

Interested in BKC-100/0.48/0.208?

Contact us for pricing, technical support, or custom requirements.