Product Search
Find the right transformer for your needs

Images are for illustration purposes only
YBW Series - Isolation Control Transformers
The YBW series three-phase isolation control transformers provide reliable electrical isolation for control circuits, with 0.1 kVA dry-type ratings, primary 220–660 V and secondary 120–240 V.
Key Features
- Three-phase isolation
- Dry-type construction, class H insulation
- Primary 220–660 V / secondary 120–240 V
- 0.1 kVA compact rating
Applications
- Control circuits
- Electrical isolation
- Outdoor installations
TECHNICAL DRAWING
Model: YBW-30/0.48/0.208 | Type: Oil-immersed transformer | Capacity: 30 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 0.1–1000 kVA |
| HV Voltage (kV) | 0.48, 0.22, 0.38, 0.66, 0.4, 10… |
| LV Voltage (kV) | 0.208, 0.24, 0.12, 0.22, 0.38, 0.4 |
| Frequency (Hz) | 60, 50 |
| Impedance (%) | 4, 6 |
| Cooling | AN |
| Efficiency | National/industry standard |
| Standard | IEEE C57 / ANSI C84.1, IEC 60076 |
| Connection | Delta-Wye (IEEE Std), Dyn11 (IEC) |
| Insulation class | H (180°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)… |
| Tap Changer | ±5% Single-tap, ±2×2.5% Multi-tap |
| No-load loss | 22–20669 W |
| Load loss | 55–51672 W |
Select 2-3 models to compare
| Compare | Model | Series | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Frequency (Hz) | Reactance | Cooling | Standard | Weight | Dimensions |
|---|---|---|---|---|---|---|---|---|---|---|---|
| YBW-0.1/0.48/0.208 | YBW | 0.1kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 0 kg | 90×80×95 mm | |
| YBW-0.1/0.48/0.24 | YBW | 0.1kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 0 kg | 90×80×95 mm | |
| YBW-0.1/0.22/0.12 | YBW | 0.1kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 0 kg | 90×80×95 mm | |
| YBW-0.1/0.38/0.22 | YBW | 0.1kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 0 kg | 90×80×95 mm | |
| YBW-0.1/0.66/0.38 | YBW | 0.1kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 0 kg | 90×80×95 mm | |
| YBW-0.1/0.4/0.22 | YBW | 0.1kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 0 kg | 90×80×95 mm | |
| YBW-0.2/0.48/0.208 | YBW | 0.2kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 5 kg | 100×90×110 mm | |
| YBW-0.2/0.48/0.24 | YBW | 0.2kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 5 kg | 100×90×110 mm | |
| YBW-0.2/0.22/0.12 | YBW | 0.2kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 5 kg | 100×90×110 mm | |
| YBW-0.2/0.38/0.22 | YBW | 0.2kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 5 kg | 100×90×110 mm | |
| YBW-0.2/0.66/0.38 | YBW | 0.2kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 5 kg | 100×90×110 mm | |
| YBW-0.2/0.4/0.22 | YBW | 0.2kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 5 kg | 100×90×110 mm | |
| YBW-0.3/0.48/0.208 | YBW | 0.3kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 5 kg | 110×100×120 mm | |
| YBW-0.3/0.48/0.24 | YBW | 0.3kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 5 kg | 110×100×120 mm | |
| YBW-0.3/0.22/0.12 | YBW | 0.3kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 5 kg | 110×100×120 mm | |
| YBW-0.3/0.38/0.22 | YBW | 0.3kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 5 kg | 110×100×120 mm | |
| YBW-0.3/0.66/0.38 | YBW | 0.3kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 5 kg | 110×100×120 mm | |
| YBW-0.3/0.4/0.22 | YBW | 0.3kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 5 kg | 110×100×120 mm | |
| YBW-0.5/0.48/0.208 | YBW | 0.5kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 5 kg | 120×110×130 mm | |
| YBW-0.5/0.48/0.24 | YBW | 0.5kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 5 kg | 120×110×130 mm | |
| YBW-0.5/0.22/0.12 | YBW | 0.5kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 5 kg | 120×110×130 mm | |
| YBW-0.5/0.38/0.22 | YBW | 0.5kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 5 kg | 120×110×130 mm | |
| YBW-0.5/0.66/0.38 | YBW | 0.5kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 5 kg | 120×110×130 mm | |
| YBW-0.5/0.4/0.22 | YBW | 0.5kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 5 kg | 120×110×130 mm | |
| YBW-1/0.48/0.208 | YBW | 1kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 10 kg | 140×130×150 mm | |
| YBW-1/0.48/0.24 | YBW | 1kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 10 kg | 140×130×150 mm | |
| YBW-1/0.22/0.12 | YBW | 1kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 10 kg | 140×130×150 mm | |
| YBW-1/0.38/0.22 | YBW | 1kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 10 kg | 140×130×150 mm | |
| YBW-1/0.66/0.38 | YBW | 1kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 10 kg | 140×130×150 mm | |
| YBW-1/0.4/0.22 | YBW | 1kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 10 kg | 140×130×150 mm | |
| YBW-1.5/0.48/0.208 | YBW | 1.5kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 15 kg | 160×140×170 mm | |
| YBW-1.5/0.48/0.24 | YBW | 1.5kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 15 kg | 160×140×170 mm | |
| YBW-1.5/0.22/0.12 | YBW | 1.5kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 15 kg | 160×140×170 mm | |
| YBW-1.5/0.38/0.22 | YBW | 1.5kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 15 kg | 160×140×170 mm | |
| YBW-1.5/0.66/0.38 | YBW | 1.5kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 15 kg | 160×140×170 mm | |
| YBW-1.5/0.4/0.22 | YBW | 1.5kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 15 kg | 160×140×170 mm | |
| YBW-2/0.48/0.208 | YBW | 2kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 15 kg | 170×150×180 mm | |
| YBW-2/0.48/0.24 | YBW | 2kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 15 kg | 170×150×180 mm | |
| YBW-2/0.22/0.12 | YBW | 2kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 15 kg | 170×150×180 mm | |
| YBW-2/0.38/0.22 | YBW | 2kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 15 kg | 170×150×180 mm | |
| YBW-2/0.66/0.38 | YBW | 2kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 15 kg | 170×150×180 mm | |
| YBW-2/0.4/0.22 | YBW | 2kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 15 kg | 170×150×180 mm | |
| YBW-3/0.48/0.208 | YBW | 3kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 20 kg | 190×170×200 mm | |
| YBW-3/0.48/0.24 | YBW | 3kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 20 kg | 190×170×200 mm | |
| YBW-3/0.22/0.12 | YBW | 3kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 20 kg | 190×170×200 mm | |
| YBW-3/0.38/0.22 | YBW | 3kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 20 kg | 190×170×200 mm | |
| YBW-3/0.66/0.38 | YBW | 3kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 20 kg | 190×170×200 mm | |
| YBW-3/0.4/0.22 | YBW | 3kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 20 kg | 190×170×200 mm | |
| YBW-4/0.48/0.208 | YBW | 4kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 25 kg | 205×180×215 mm | |
| YBW-4/0.48/0.24 | YBW | 4kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 25 kg | 205×180×215 mm | |
| YBW-4/0.22/0.12 | YBW | 4kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 25 kg | 205×180×215 mm | |
| YBW-4/0.38/0.22 | YBW | 4kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 25 kg | 205×180×215 mm | |
| YBW-4/0.66/0.38 | YBW | 4kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 25 kg | 205×180×215 mm | |
| YBW-4/0.4/0.22 | YBW | 4kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 25 kg | 205×180×215 mm | |
| YBW-5/0.48/0.208 | YBW | 5kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 30 kg | 220×190×230 mm | |
| YBW-5/0.48/0.24 | YBW | 5kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 30 kg | 220×190×230 mm | |
| YBW-5/0.22/0.12 | YBW | 5kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 30 kg | 220×190×230 mm | |
| YBW-5/0.38/0.22 | YBW | 5kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 30 kg | 220×190×230 mm | |
| YBW-5/0.66/0.38 | YBW | 5kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 30 kg | 220×190×230 mm | |
| YBW-5/0.4/0.22 | YBW | 5kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 30 kg | 220×190×230 mm | |
| YBW-6.3/0.48/0.208 | YBW | 6.3kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 40 kg | 235×205×245 mm | |
| YBW-6.3/0.48/0.24 | YBW | 6.3kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 40 kg | 235×205×245 mm | |
| YBW-6.3/0.22/0.12 | YBW | 6.3kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 40 kg | 235×205×245 mm | |
| YBW-6.3/0.38/0.22 | YBW | 6.3kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 40 kg | 235×205×245 mm | |
| YBW-6.3/0.66/0.38 | YBW | 6.3kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 40 kg | 235×205×245 mm | |
| YBW-6.3/0.4/0.22 | YBW | 6.3kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 40 kg | 235×205×245 mm | |
| YBW-8/0.48/0.208 | YBW | 8kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 45 kg | 255×225×265 mm | |
| YBW-8/0.48/0.24 | YBW | 8kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 45 kg | 255×225×265 mm | |
| YBW-8/0.22/0.12 | YBW | 8kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 45 kg | 255×225×265 mm | |
| YBW-8/0.38/0.22 | YBW | 8kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 45 kg | 255×225×265 mm | |
| YBW-8/0.66/0.38 | YBW | 8kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 45 kg | 255×225×265 mm | |
| YBW-8/0.4/0.22 | YBW | 8kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 45 kg | 255×225×265 mm | |
| YBW-10/0.48/0.208 | YBW | 10kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 55 kg | 280×240×290 mm | |
| YBW-10/0.48/0.24 | YBW | 10kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 55 kg | 280×240×290 mm | |
| YBW-10/0.22/0.12 | YBW | 10kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 55 kg | 280×240×290 mm | |
| YBW-10/0.38/0.22 | YBW | 10kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 55 kg | 280×240×290 mm | |
| YBW-10/0.66/0.38 | YBW | 10kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 55 kg | 280×240×290 mm | |
| YBW-10/0.4/0.22 | YBW | 10kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 55 kg | 280×240×290 mm | |
| YBW-15/0.48/0.208 | YBW | 15kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 75 kg | 320×270×320 mm | |
| YBW-15/0.48/0.24 | YBW | 15kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 75 kg | 320×270×320 mm | |
| YBW-15/0.22/0.12 | YBW | 15kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 75 kg | 320×270×320 mm | |
| YBW-15/0.38/0.22 | YBW | 15kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 75 kg | 320×270×320 mm | |
| YBW-15/0.66/0.38 | YBW | 15kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 75 kg | 320×270×320 mm | |
| YBW-15/0.4/0.22 | YBW | 15kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 75 kg | 320×270×320 mm | |
| YBW-20/0.48/0.208 | YBW | 20kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 90 kg | 350×300×350 mm | |
| YBW-20/0.48/0.24 | YBW | 20kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 90 kg | 350×300×350 mm | |
| YBW-20/0.22/0.12 | YBW | 20kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 90 kg | 350×300×350 mm | |
| YBW-20/0.38/0.22 | YBW | 20kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 90 kg | 350×300×350 mm | |
| YBW-20/0.66/0.38 | YBW | 20kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 90 kg | 350×300×350 mm | |
| YBW-20/0.4/0.22 | YBW | 20kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 90 kg | 350×300×350 mm | |
| YBW-25/0.48/0.208 | YBW | 25kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 110 kg | 375×320×370 mm | |
| YBW-25/0.48/0.24 | YBW | 25kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 110 kg | 375×320×370 mm | |
| YBW-25/0.22/0.12 | YBW | 25kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 110 kg | 375×320×370 mm | |
| YBW-25/0.38/0.22 | YBW | 25kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 110 kg | 375×320×370 mm | |
| YBW-25/0.66/0.38 | YBW | 25kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 110 kg | 375×320×370 mm | |
| YBW-25/0.4/0.22 | YBW | 25kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 110 kg | 375×320×370 mm | |
| YBW-30/0.48/0.208 | YBW | 30kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 130 kg | 400×340×390 mm | |
| YBW-30/0.48/0.24 | YBW | 30kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 130 kg | 400×340×390 mm | |
| YBW-30/0.22/0.12 | YBW | 30kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 130 kg | 400×340×390 mm | |
| YBW-30/0.38/0.22 | YBW | 30kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 130 kg | 400×340×390 mm | |
| YBW-30/0.66/0.38 | YBW | 30kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 130 kg | 400×340×390 mm | |
| YBW-30/0.4/0.22 | YBW | 30kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 130 kg | 400×340×390 mm | |
| YBW-40/0.48/0.208 | YBW | 40kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 165 kg | 425×360×420 mm | |
| YBW-40/0.48/0.24 | YBW | 40kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 165 kg | 425×360×420 mm | |
| YBW-40/0.22/0.12 | YBW | 40kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 165 kg | 425×360×420 mm | |
| YBW-40/0.38/0.22 | YBW | 40kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 165 kg | 425×360×420 mm | |
| YBW-40/0.66/0.38 | YBW | 40kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 165 kg | 425×360×420 mm | |
| YBW-40/0.4/0.22 | YBW | 40kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 165 kg | 425×360×420 mm | |
| YBW-50/0.48/0.208 | YBW | 50kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 200 kg | 450×380×450 mm | |
| YBW-50/0.48/0.24 | YBW | 50kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 200 kg | 450×380×450 mm | |
| YBW-50/0.22/0.12 | YBW | 50kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 200 kg | 450×380×450 mm | |
| YBW-50/0.38/0.22 | YBW | 50kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 200 kg | 450×380×450 mm | |
| YBW-50/0.66/0.38 | YBW | 50kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 200 kg | 450×380×450 mm | |
| YBW-50/0.4/0.22 | YBW | 50kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 200 kg | 450×380×450 mm | |
| YBW-63/0.48/0.208 | YBW | 63kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 240 kg | 475×400×475 mm | |
| YBW-63/0.48/0.24 | YBW | 63kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 240 kg | 475×400×475 mm | |
| YBW-63/0.22/0.12 | YBW | 63kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 240 kg | 475×400×475 mm | |
| YBW-63/0.38/0.22 | YBW | 63kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 240 kg | 475×400×475 mm | |
| YBW-63/0.66/0.38 | YBW | 63kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 240 kg | 475×400×475 mm | |
| YBW-63/0.4/0.22 | YBW | 63kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 240 kg | 475×400×475 mm | |
| YBW-80/0.48/0.208 | YBW | 80kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 295 kg | 510×430×510 mm | |
| YBW-80/0.48/0.24 | YBW | 80kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 295 kg | 510×430×510 mm | |
| YBW-80/0.22/0.12 | YBW | 80kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 295 kg | 510×430×510 mm | |
| YBW-80/0.38/0.22 | YBW | 80kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 295 kg | 510×430×510 mm | |
| YBW-80/0.66/0.38 | YBW | 80kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 295 kg | 510×430×510 mm | |
| YBW-80/0.4/0.22 | YBW | 80kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 295 kg | 510×430×510 mm | |
| YBW-100/0.48/0.208 | YBW | 100kVA | 0.48 | 0.208 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 350 kg | 550×460×550 mm | |
| YBW-100/0.48/0.24 | YBW | 100kVA | 0.48 | 0.24 | 60 | 4 | AN | IEEE C57 / ANSI C84.1 | 350 kg | 550×460×550 mm | |
| YBW-100/0.22/0.12 | YBW | 100kVA | 0.22 | 0.12 | 50 | 4 | AN | IEC 60076 | 350 kg | 550×460×550 mm | |
| YBW-100/0.38/0.22 | YBW | 100kVA | 0.38 | 0.22 | 50 | 4 | AN | IEC 60076 | 350 kg | 550×460×550 mm | |
| YBW-100/0.66/0.38 | YBW | 100kVA | 0.66 | 0.38 | 50 | 4 | AN | IEC 60076 | 350 kg | 550×460×550 mm | |
| YBW-100/0.4/0.22 | YBW | 100kVA | 0.4 | 0.22 | 50 | 4 | AN | IEC 60076 | 350 kg | 550×460×550 mm | |
| YBW-125/0.48/0.208 | YBW | 125kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 420 kg | 570×475×570 mm | |
| YBW-125/0.48/0.24 | YBW | 125kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 420 kg | 570×475×570 mm | |
| YBW-125/0.22/0.12 | YBW | 125kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 420 kg | 570×475×570 mm | |
| YBW-125/0.38/0.22 | YBW | 125kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 420 kg | 570×475×570 mm | |
| YBW-125/0.66/0.38 | YBW | 125kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 420 kg | 570×475×570 mm | |
| YBW-125/0.4/0.22 | YBW | 125kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 420 kg | 570×475×570 mm | |
| YBW-160/0.48/0.208 | YBW | 160kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 520 kg | 600×500×600 mm | |
| YBW-160/0.48/0.24 | YBW | 160kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 520 kg | 600×500×600 mm | |
| YBW-160/0.22/0.12 | YBW | 160kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 520 kg | 600×500×600 mm | |
| YBW-160/0.38/0.22 | YBW | 160kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 520 kg | 600×500×600 mm | |
| YBW-160/0.66/0.38 | YBW | 160kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 520 kg | 600×500×600 mm | |
| YBW-160/0.4/0.22 | YBW | 160kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 520 kg | 600×500×600 mm | |
| YBW-200/0.48/0.208 | YBW | 200kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 620 kg | 650×540×650 mm | |
| YBW-200/0.48/0.24 | YBW | 200kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 620 kg | 650×540×650 mm | |
| YBW-200/0.22/0.12 | YBW | 200kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 620 kg | 650×540×650 mm | |
| YBW-200/0.38/0.22 | YBW | 200kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 620 kg | 650×540×650 mm | |
| YBW-200/0.66/0.38 | YBW | 200kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 620 kg | 650×540×650 mm | |
| YBW-200/0.4/0.22 | YBW | 200kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 620 kg | 650×540×650 mm | |
| YBW-250/0.48/0.208 | YBW | 250kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 750 kg | 700×580×700 mm | |
| YBW-250/0.48/0.24 | YBW | 250kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 750 kg | 700×580×700 mm | |
| YBW-250/0.22/0.12 | YBW | 250kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 750 kg | 700×580×700 mm | |
| YBW-250/0.38/0.22 | YBW | 250kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 750 kg | 700×580×700 mm | |
| YBW-250/0.66/0.38 | YBW | 250kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 750 kg | 700×580×700 mm | |
| YBW-250/0.4/0.22 | YBW | 250kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 750 kg | 700×580×700 mm | |
| YBW-315/0.48/0.208 | YBW | 315kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 900 kg | 750×620×750 mm | |
| YBW-315/0.48/0.24 | YBW | 315kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 900 kg | 750×620×750 mm | |
| YBW-315/0.22/0.12 | YBW | 315kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 900 kg | 750×620×750 mm | |
| YBW-315/0.38/0.22 | YBW | 315kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 900 kg | 750×620×750 mm | |
| YBW-315/0.66/0.38 | YBW | 315kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 900 kg | 750×620×750 mm | |
| YBW-315/0.4/0.22 | YBW | 315kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 900 kg | 750×620×750 mm | |
| YBW-400/0.48/0.208 | YBW | 400kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1100 kg | 800×660×800 mm | |
| YBW-400/0.48/0.24 | YBW | 400kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1100 kg | 800×660×800 mm | |
| YBW-400/0.22/0.12 | YBW | 400kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 1100 kg | 800×660×800 mm | |
| YBW-400/0.38/0.22 | YBW | 400kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 1100 kg | 800×660×800 mm | |
| YBW-400/0.66/0.38 | YBW | 400kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 1100 kg | 800×660×800 mm | |
| YBW-400/0.4/0.22 | YBW | 400kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 1100 kg | 800×660×800 mm | |
| YBW-500/0.48/0.208 | YBW | 500kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1300 kg | 850×700×850 mm | |
| YBW-500/0.48/0.24 | YBW | 500kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1300 kg | 850×700×850 mm | |
| YBW-500/0.22/0.12 | YBW | 500kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 1300 kg | 850×700×850 mm | |
| YBW-500/0.38/0.22 | YBW | 500kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 1300 kg | 850×700×850 mm | |
| YBW-500/0.66/0.38 | YBW | 500kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 1300 kg | 850×700×850 mm | |
| YBW-500/0.4/0.22 | YBW | 500kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 1300 kg | 850×700×850 mm | |
| YBW-630/0.48/0.208 | YBW | 630kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1600 kg | 900×750×950 mm | |
| YBW-630/0.48/0.24 | YBW | 630kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1600 kg | 900×750×950 mm | |
| YBW-630/0.22/0.12 | YBW | 630kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 1600 kg | 900×750×950 mm | |
| YBW-630/0.38/0.22 | YBW | 630kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 1600 kg | 900×750×950 mm | |
| YBW-630/0.66/0.38 | YBW | 630kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 1600 kg | 900×750×950 mm | |
| YBW-630/0.4/0.22 | YBW | 630kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 1600 kg | 900×750×950 mm | |
| YBW-800/0.48/0.208 | YBW | 800kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1950 kg | 1000×820×1000 mm | |
| YBW-800/0.48/0.24 | YBW | 800kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 1950 kg | 1000×820×1000 mm | |
| YBW-800/0.22/0.12 | YBW | 800kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 1950 kg | 1000×820×1000 mm | |
| YBW-800/0.38/0.22 | YBW | 800kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 1950 kg | 1000×820×1000 mm | |
| YBW-800/0.66/0.38 | YBW | 800kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 1950 kg | 1000×820×1000 mm | |
| YBW-800/0.4/0.22 | YBW | 800kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 1950 kg | 1000×820×1000 mm | |
| YBW-1000/0.48/0.208 | YBW | 1000kVA | 0.48 | 0.208 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 2300 kg | 1050×880×1100 mm | |
| YBW-1000/0.48/0.24 | YBW | 1000kVA | 0.48 | 0.24 | 60 | 6 | AN | IEEE C57 / ANSI C84.1 | 2300 kg | 1050×880×1100 mm | |
| YBW-1000/0.22/0.12 | YBW | 1000kVA | 0.22 | 0.12 | 50 | 6 | AN | IEC 60076 | 2300 kg | 1050×880×1100 mm | |
| YBW-1000/0.38/0.22 | YBW | 1000kVA | 0.38 | 0.22 | 50 | 6 | AN | IEC 60076 | 2300 kg | 1050×880×1100 mm | |
| YBW-1000/0.66/0.38 | YBW | 1000kVA | 0.66 | 0.38 | 50 | 6 | AN | IEC 60076 | 2300 kg | 1050×880×1100 mm | |
| YBW-1000/0.4/0.22 | YBW | 1000kVA | 0.4 | 0.22 | 50 | 6 | AN | IEC 60076 | 2300 kg | 1050×880×1100 mm | |
| YBW-0.1/10/0.4 | YBW | 0.1kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 0 kg | 90×80×95 mm | |
| YBW-0.1/6/0.4 | YBW | 0.1kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 0 kg | 90×80×95 mm | |
| YBW-0.2/10/0.4 | YBW | 0.2kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 5 kg | 100×90×110 mm | |
| YBW-0.2/6/0.4 | YBW | 0.2kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 5 kg | 100×90×110 mm | |
| YBW-0.3/10/0.4 | YBW | 0.3kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 5 kg | 110×100×120 mm | |
| YBW-0.3/6/0.4 | YBW | 0.3kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 5 kg | 110×100×120 mm | |
| YBW-0.5/10/0.4 | YBW | 0.5kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 5 kg | 120×110×130 mm | |
| YBW-0.5/6/0.4 | YBW | 0.5kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 5 kg | 120×110×130 mm | |
| YBW-1/10/0.4 | YBW | 1kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 10 kg | 140×130×150 mm | |
| YBW-1/6/0.4 | YBW | 1kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 10 kg | 140×130×150 mm | |
| YBW-1.5/10/0.4 | YBW | 1.5kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 15 kg | 160×140×170 mm | |
| YBW-1.5/6/0.4 | YBW | 1.5kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 15 kg | 160×140×170 mm | |
| YBW-2/10/0.4 | YBW | 2kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 15 kg | 170×150×180 mm | |
| YBW-2/6/0.4 | YBW | 2kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 15 kg | 170×150×180 mm | |
| YBW-3/10/0.4 | YBW | 3kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 20 kg | 190×170×200 mm | |
| YBW-3/6/0.4 | YBW | 3kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 20 kg | 190×170×200 mm | |
| YBW-4/10/0.4 | YBW | 4kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 25 kg | 205×180×215 mm | |
| YBW-4/6/0.4 | YBW | 4kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 25 kg | 205×180×215 mm | |
| YBW-5/10/0.4 | YBW | 5kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 30 kg | 220×190×230 mm | |
| YBW-5/6/0.4 | YBW | 5kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 30 kg | 220×190×230 mm | |
| YBW-6.3/10/0.4 | YBW | 6.3kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 40 kg | 235×205×245 mm | |
| YBW-6.3/6/0.4 | YBW | 6.3kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 40 kg | 235×205×245 mm | |
| YBW-8/10/0.4 | YBW | 8kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 45 kg | 255×225×265 mm | |
| YBW-8/6/0.4 | YBW | 8kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 45 kg | 255×225×265 mm | |
| YBW-10/10/0.4 | YBW | 10kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 55 kg | 280×240×290 mm | |
| YBW-10/6/0.4 | YBW | 10kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 55 kg | 280×240×290 mm | |
| YBW-15/10/0.4 | YBW | 15kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 75 kg | 320×270×320 mm | |
| YBW-15/6/0.4 | YBW | 15kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 75 kg | 320×270×320 mm | |
| YBW-20/10/0.4 | YBW | 20kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 90 kg | 350×300×350 mm | |
| YBW-20/6/0.4 | YBW | 20kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 90 kg | 350×300×350 mm | |
| YBW-25/10/0.4 | YBW | 25kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 110 kg | 375×320×370 mm | |
| YBW-25/6/0.4 | YBW | 25kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 110 kg | 375×320×370 mm | |
| YBW-30/10/0.4 | YBW | 30kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 130 kg | 400×340×390 mm | |
| YBW-30/6/0.4 | YBW | 30kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 130 kg | 400×340×390 mm | |
| YBW-40/10/0.4 | YBW | 40kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 165 kg | 425×360×420 mm | |
| YBW-40/6/0.4 | YBW | 40kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 165 kg | 425×360×420 mm | |
| YBW-50/10/0.4 | YBW | 50kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 200 kg | 450×380×450 mm | |
| YBW-50/6/0.4 | YBW | 50kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 200 kg | 450×380×450 mm | |
| YBW-63/10/0.4 | YBW | 63kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 240 kg | 475×400×475 mm | |
| YBW-63/6/0.4 | YBW | 63kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 240 kg | 475×400×475 mm | |
| YBW-80/10/0.4 | YBW | 80kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 295 kg | 510×430×510 mm | |
| YBW-80/6/0.4 | YBW | 80kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 295 kg | 510×430×510 mm | |
| YBW-100/10/0.4 | YBW | 100kVA | 10 | 0.4 | 50 | 4 | AN | IEC 60076 | 350 kg | 550×460×550 mm | |
| YBW-100/6/0.4 | YBW | 100kVA | 6 | 0.4 | 50 | 4 | AN | IEC 60076 | 350 kg | 550×460×550 mm | |
| YBW-125/10/0.4 | YBW | 125kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 420 kg | 570×475×570 mm | |
| YBW-125/6/0.4 | YBW | 125kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 420 kg | 570×475×570 mm | |
| YBW-160/10/0.4 | YBW | 160kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 520 kg | 600×500×600 mm | |
| YBW-160/6/0.4 | YBW | 160kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 520 kg | 600×500×600 mm | |
| YBW-200/10/0.4 | YBW | 200kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 620 kg | 650×540×650 mm | |
| YBW-200/6/0.4 | YBW | 200kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 620 kg | 650×540×650 mm | |
| YBW-250/10/0.4 | YBW | 250kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 750 kg | 700×580×700 mm | |
| YBW-250/6/0.4 | YBW | 250kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 750 kg | 700×580×700 mm | |
| YBW-315/10/0.4 | YBW | 315kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 900 kg | 750×620×750 mm | |
| YBW-315/6/0.4 | YBW | 315kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 900 kg | 750×620×750 mm | |
| YBW-400/10/0.4 | YBW | 400kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 1100 kg | 800×660×800 mm | |
| YBW-400/6/0.4 | YBW | 400kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 1100 kg | 800×660×800 mm | |
| YBW-500/10/0.4 | YBW | 500kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 1300 kg | 850×700×850 mm | |
| YBW-500/6/0.4 | YBW | 500kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 1300 kg | 850×700×850 mm | |
| YBW-630/10/0.4 | YBW | 630kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 1600 kg | 900×750×950 mm | |
| YBW-630/6/0.4 | YBW | 630kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 1600 kg | 900×750×950 mm | |
| YBW-800/10/0.4 | YBW | 800kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 1950 kg | 1000×820×1000 mm | |
| YBW-800/6/0.4 | YBW | 800kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 1950 kg | 1000×820×1000 mm | |
| YBW-1000/10/0.4 | YBW | 1000kVA | 10 | 0.4 | 50 | 6 | AN | IEC 60076 | 2300 kg | 1050×880×1100 mm | |
| YBW-1000/6/0.4 | YBW | 1000kVA | 6 | 0.4 | 50 | 6 | AN | IEC 60076 | 2300 kg | 1050×880×1100 mm |
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
1 · Configure
2 · Your price
EXW (FOB Qingdao)
$10
Range $10 ~ $11 (±8%)
Price Breakdown
| Base price (interpolation) | $10 |
| × Product factor | ×1.0000 |
| × Country factor | ×1.0000 |
| × Copper-linked factor | ×1.0000 |
| + Options / accessories | $0 |
Shipping quoted separately per destination port.
Aluminum winding — no copper linkage
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.