QDTB® Transformer

Product Search

Find the right transformer for your needs

ZGS Isolation Transformers Series Special/Isolation/Control Transformers

256 Models available

ZGS Isolation Transformers Special/Isolation/Control Transformers

Images are for illustration purposes only

ZGS Series - Isolation Control Transformers

The ZGS series three-phase isolation control transformers provide galvanic isolation between primary and secondary circuits, with compact 0.1 kVA dry-type ratings, primary 220–660 V and secondary 120–240 V.

Key Features

  • Three-phase isolation
  • Dry-type construction, class H insulation
  • Primary 220–660 V / secondary 120–240 V
  • Compact 0.1 kVA rating

Applications

  • Control and auxiliary circuits
  • Electrical isolation
  • Mining face equipment

TECHNICAL DRAWING

Model: ZGS-30/0.48/0.208 | Type: Oil-immersed transformer | Capacity: 30 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.120mm150mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDelta-Wye (IEEE Std)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level90mm

TOP VIEW

1U1V1W2U2V2W2N90mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity0.1–1000 kVA
HV Voltage (kV)0.48, 0.22, 0.38, 0.66, 0.4, 10…
LV Voltage (kV)0.208, 0.24, 0.12, 0.22, 0.38, 0.4
Frequency (Hz)60, 50
Impedance (%)4, 6
CoolingAN
EfficiencyNational/industry standard
StandardIEEE C57 / ANSI C84.1, IEC 60076
ConnectionDelta-Wye (IEEE Std), Dyn11 (IEC)
Insulation classH (180°C)
Allowed temperature rise65
Noise level≤33 dB(A), ≤34 dB(A), ≤35 dB(A), ≤36 dB(A), ≤37 dB(A), ≤38 dB(A)…
Tap Changer±5% Single-tap, ±2×2.5% Multi-tap
No-load loss22–20669 W
Load loss55–51672 W
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)LV Voltage (kV)Frequency (Hz)ReactanceCoolingStandardWeightDimensions
ZGS-0.1/0.48/0.208ZGS Isolation Transformers0.1kVA0.480.208604ANIEEE C57 / ANSI C84.10 kg90×80×95 mm
ZGS-0.1/0.48/0.24ZGS Isolation Transformers0.1kVA0.480.24604ANIEEE C57 / ANSI C84.10 kg90×80×95 mm
ZGS-0.1/0.22/0.12ZGS Isolation Transformers0.1kVA0.220.12504ANIEC 600760 kg90×80×95 mm
ZGS-0.1/0.38/0.22ZGS Isolation Transformers0.1kVA0.380.22504ANIEC 600760 kg90×80×95 mm
ZGS-0.1/0.66/0.38ZGS Isolation Transformers0.1kVA0.660.38504ANIEC 600760 kg90×80×95 mm
ZGS-0.1/0.4/0.22ZGS Isolation Transformers0.1kVA0.40.22504ANIEC 600760 kg90×80×95 mm
ZGS-0.2/0.48/0.208ZGS Isolation Transformers0.2kVA0.480.208604ANIEEE C57 / ANSI C84.15 kg100×90×110 mm
ZGS-0.2/0.48/0.24ZGS Isolation Transformers0.2kVA0.480.24604ANIEEE C57 / ANSI C84.15 kg100×90×110 mm
ZGS-0.2/0.22/0.12ZGS Isolation Transformers0.2kVA0.220.12504ANIEC 600765 kg100×90×110 mm
ZGS-0.2/0.38/0.22ZGS Isolation Transformers0.2kVA0.380.22504ANIEC 600765 kg100×90×110 mm
ZGS-0.2/0.66/0.38ZGS Isolation Transformers0.2kVA0.660.38504ANIEC 600765 kg100×90×110 mm
ZGS-0.2/0.4/0.22ZGS Isolation Transformers0.2kVA0.40.22504ANIEC 600765 kg100×90×110 mm
ZGS-0.3/0.48/0.208ZGS Isolation Transformers0.3kVA0.480.208604ANIEEE C57 / ANSI C84.15 kg110×100×120 mm
ZGS-0.3/0.48/0.24ZGS Isolation Transformers0.3kVA0.480.24604ANIEEE C57 / ANSI C84.15 kg110×100×120 mm
ZGS-0.3/0.22/0.12ZGS Isolation Transformers0.3kVA0.220.12504ANIEC 600765 kg110×100×120 mm
ZGS-0.3/0.38/0.22ZGS Isolation Transformers0.3kVA0.380.22504ANIEC 600765 kg110×100×120 mm
ZGS-0.3/0.66/0.38ZGS Isolation Transformers0.3kVA0.660.38504ANIEC 600765 kg110×100×120 mm
ZGS-0.3/0.4/0.22ZGS Isolation Transformers0.3kVA0.40.22504ANIEC 600765 kg110×100×120 mm
ZGS-0.5/0.48/0.208ZGS Isolation Transformers0.5kVA0.480.208604ANIEEE C57 / ANSI C84.15 kg120×110×130 mm
ZGS-0.5/0.48/0.24ZGS Isolation Transformers0.5kVA0.480.24604ANIEEE C57 / ANSI C84.15 kg120×110×130 mm
ZGS-0.5/0.22/0.12ZGS Isolation Transformers0.5kVA0.220.12504ANIEC 600765 kg120×110×130 mm
ZGS-0.5/0.38/0.22ZGS Isolation Transformers0.5kVA0.380.22504ANIEC 600765 kg120×110×130 mm
ZGS-0.5/0.66/0.38ZGS Isolation Transformers0.5kVA0.660.38504ANIEC 600765 kg120×110×130 mm
ZGS-0.5/0.4/0.22ZGS Isolation Transformers0.5kVA0.40.22504ANIEC 600765 kg120×110×130 mm
ZGS-1/0.48/0.208ZGS Isolation Transformers1kVA0.480.208604ANIEEE C57 / ANSI C84.110 kg140×130×150 mm
ZGS-1/0.48/0.24ZGS Isolation Transformers1kVA0.480.24604ANIEEE C57 / ANSI C84.110 kg140×130×150 mm
ZGS-1/0.22/0.12ZGS Isolation Transformers1kVA0.220.12504ANIEC 6007610 kg140×130×150 mm
ZGS-1/0.38/0.22ZGS Isolation Transformers1kVA0.380.22504ANIEC 6007610 kg140×130×150 mm
ZGS-1/0.66/0.38ZGS Isolation Transformers1kVA0.660.38504ANIEC 6007610 kg140×130×150 mm
ZGS-1/0.4/0.22ZGS Isolation Transformers1kVA0.40.22504ANIEC 6007610 kg140×130×150 mm
ZGS-1.5/0.48/0.208ZGS Isolation Transformers1.5kVA0.480.208604ANIEEE C57 / ANSI C84.115 kg160×140×170 mm
ZGS-1.5/0.48/0.24ZGS Isolation Transformers1.5kVA0.480.24604ANIEEE C57 / ANSI C84.115 kg160×140×170 mm
ZGS-1.5/0.22/0.12ZGS Isolation Transformers1.5kVA0.220.12504ANIEC 6007615 kg160×140×170 mm
ZGS-1.5/0.38/0.22ZGS Isolation Transformers1.5kVA0.380.22504ANIEC 6007615 kg160×140×170 mm
ZGS-1.5/0.66/0.38ZGS Isolation Transformers1.5kVA0.660.38504ANIEC 6007615 kg160×140×170 mm
ZGS-1.5/0.4/0.22ZGS Isolation Transformers1.5kVA0.40.22504ANIEC 6007615 kg160×140×170 mm
ZGS-2/0.48/0.208ZGS Isolation Transformers2kVA0.480.208604ANIEEE C57 / ANSI C84.115 kg170×150×180 mm
ZGS-2/0.48/0.24ZGS Isolation Transformers2kVA0.480.24604ANIEEE C57 / ANSI C84.115 kg170×150×180 mm
ZGS-2/0.22/0.12ZGS Isolation Transformers2kVA0.220.12504ANIEC 6007615 kg170×150×180 mm
ZGS-2/0.38/0.22ZGS Isolation Transformers2kVA0.380.22504ANIEC 6007615 kg170×150×180 mm
ZGS-2/0.66/0.38ZGS Isolation Transformers2kVA0.660.38504ANIEC 6007615 kg170×150×180 mm
ZGS-2/0.4/0.22ZGS Isolation Transformers2kVA0.40.22504ANIEC 6007615 kg170×150×180 mm
ZGS-3/0.48/0.208ZGS Isolation Transformers3kVA0.480.208604ANIEEE C57 / ANSI C84.120 kg190×170×200 mm
ZGS-3/0.48/0.24ZGS Isolation Transformers3kVA0.480.24604ANIEEE C57 / ANSI C84.120 kg190×170×200 mm
ZGS-3/0.22/0.12ZGS Isolation Transformers3kVA0.220.12504ANIEC 6007620 kg190×170×200 mm
ZGS-3/0.38/0.22ZGS Isolation Transformers3kVA0.380.22504ANIEC 6007620 kg190×170×200 mm
ZGS-3/0.66/0.38ZGS Isolation Transformers3kVA0.660.38504ANIEC 6007620 kg190×170×200 mm
ZGS-3/0.4/0.22ZGS Isolation Transformers3kVA0.40.22504ANIEC 6007620 kg190×170×200 mm
ZGS-4/0.48/0.208ZGS Isolation Transformers4kVA0.480.208604ANIEEE C57 / ANSI C84.125 kg205×180×215 mm
ZGS-4/0.48/0.24ZGS Isolation Transformers4kVA0.480.24604ANIEEE C57 / ANSI C84.125 kg205×180×215 mm
ZGS-4/0.22/0.12ZGS Isolation Transformers4kVA0.220.12504ANIEC 6007625 kg205×180×215 mm
ZGS-4/0.38/0.22ZGS Isolation Transformers4kVA0.380.22504ANIEC 6007625 kg205×180×215 mm
ZGS-4/0.66/0.38ZGS Isolation Transformers4kVA0.660.38504ANIEC 6007625 kg205×180×215 mm
ZGS-4/0.4/0.22ZGS Isolation Transformers4kVA0.40.22504ANIEC 6007625 kg205×180×215 mm
ZGS-5/0.48/0.208ZGS Isolation Transformers5kVA0.480.208604ANIEEE C57 / ANSI C84.130 kg220×190×230 mm
ZGS-5/0.48/0.24ZGS Isolation Transformers5kVA0.480.24604ANIEEE C57 / ANSI C84.130 kg220×190×230 mm
ZGS-5/0.22/0.12ZGS Isolation Transformers5kVA0.220.12504ANIEC 6007630 kg220×190×230 mm
ZGS-5/0.38/0.22ZGS Isolation Transformers5kVA0.380.22504ANIEC 6007630 kg220×190×230 mm
ZGS-5/0.66/0.38ZGS Isolation Transformers5kVA0.660.38504ANIEC 6007630 kg220×190×230 mm
ZGS-5/0.4/0.22ZGS Isolation Transformers5kVA0.40.22504ANIEC 6007630 kg220×190×230 mm
ZGS-6.3/0.48/0.208ZGS Isolation Transformers6.3kVA0.480.208604ANIEEE C57 / ANSI C84.140 kg235×205×245 mm
ZGS-6.3/0.48/0.24ZGS Isolation Transformers6.3kVA0.480.24604ANIEEE C57 / ANSI C84.140 kg235×205×245 mm
ZGS-6.3/0.22/0.12ZGS Isolation Transformers6.3kVA0.220.12504ANIEC 6007640 kg235×205×245 mm
ZGS-6.3/0.38/0.22ZGS Isolation Transformers6.3kVA0.380.22504ANIEC 6007640 kg235×205×245 mm
ZGS-6.3/0.66/0.38ZGS Isolation Transformers6.3kVA0.660.38504ANIEC 6007640 kg235×205×245 mm
ZGS-6.3/0.4/0.22ZGS Isolation Transformers6.3kVA0.40.22504ANIEC 6007640 kg235×205×245 mm
ZGS-8/0.48/0.208ZGS Isolation Transformers8kVA0.480.208604ANIEEE C57 / ANSI C84.145 kg255×225×265 mm
ZGS-8/0.48/0.24ZGS Isolation Transformers8kVA0.480.24604ANIEEE C57 / ANSI C84.145 kg255×225×265 mm
ZGS-8/0.22/0.12ZGS Isolation Transformers8kVA0.220.12504ANIEC 6007645 kg255×225×265 mm
ZGS-8/0.38/0.22ZGS Isolation Transformers8kVA0.380.22504ANIEC 6007645 kg255×225×265 mm
ZGS-8/0.66/0.38ZGS Isolation Transformers8kVA0.660.38504ANIEC 6007645 kg255×225×265 mm
ZGS-8/0.4/0.22ZGS Isolation Transformers8kVA0.40.22504ANIEC 6007645 kg255×225×265 mm
ZGS-10/0.48/0.208ZGS Isolation Transformers10kVA0.480.208604ANIEEE C57 / ANSI C84.155 kg280×240×290 mm
ZGS-10/0.48/0.24ZGS Isolation Transformers10kVA0.480.24604ANIEEE C57 / ANSI C84.155 kg280×240×290 mm
ZGS-10/0.22/0.12ZGS Isolation Transformers10kVA0.220.12504ANIEC 6007655 kg280×240×290 mm
ZGS-10/0.38/0.22ZGS Isolation Transformers10kVA0.380.22504ANIEC 6007655 kg280×240×290 mm
ZGS-10/0.66/0.38ZGS Isolation Transformers10kVA0.660.38504ANIEC 6007655 kg280×240×290 mm
ZGS-10/0.4/0.22ZGS Isolation Transformers10kVA0.40.22504ANIEC 6007655 kg280×240×290 mm
ZGS-15/0.48/0.208ZGS Isolation Transformers15kVA0.480.208604ANIEEE C57 / ANSI C84.175 kg320×270×320 mm
ZGS-15/0.48/0.24ZGS Isolation Transformers15kVA0.480.24604ANIEEE C57 / ANSI C84.175 kg320×270×320 mm
ZGS-15/0.22/0.12ZGS Isolation Transformers15kVA0.220.12504ANIEC 6007675 kg320×270×320 mm
ZGS-15/0.38/0.22ZGS Isolation Transformers15kVA0.380.22504ANIEC 6007675 kg320×270×320 mm
ZGS-15/0.66/0.38ZGS Isolation Transformers15kVA0.660.38504ANIEC 6007675 kg320×270×320 mm
ZGS-15/0.4/0.22ZGS Isolation Transformers15kVA0.40.22504ANIEC 6007675 kg320×270×320 mm
ZGS-20/0.48/0.208ZGS Isolation Transformers20kVA0.480.208604ANIEEE C57 / ANSI C84.190 kg350×300×350 mm
ZGS-20/0.48/0.24ZGS Isolation Transformers20kVA0.480.24604ANIEEE C57 / ANSI C84.190 kg350×300×350 mm
ZGS-20/0.22/0.12ZGS Isolation Transformers20kVA0.220.12504ANIEC 6007690 kg350×300×350 mm
ZGS-20/0.38/0.22ZGS Isolation Transformers20kVA0.380.22504ANIEC 6007690 kg350×300×350 mm
ZGS-20/0.66/0.38ZGS Isolation Transformers20kVA0.660.38504ANIEC 6007690 kg350×300×350 mm
ZGS-20/0.4/0.22ZGS Isolation Transformers20kVA0.40.22504ANIEC 6007690 kg350×300×350 mm
ZGS-25/0.48/0.208ZGS Isolation Transformers25kVA0.480.208604ANIEEE C57 / ANSI C84.1110 kg375×320×370 mm
ZGS-25/0.48/0.24ZGS Isolation Transformers25kVA0.480.24604ANIEEE C57 / ANSI C84.1110 kg375×320×370 mm
ZGS-25/0.22/0.12ZGS Isolation Transformers25kVA0.220.12504ANIEC 60076110 kg375×320×370 mm
ZGS-25/0.38/0.22ZGS Isolation Transformers25kVA0.380.22504ANIEC 60076110 kg375×320×370 mm
ZGS-25/0.66/0.38ZGS Isolation Transformers25kVA0.660.38504ANIEC 60076110 kg375×320×370 mm
ZGS-25/0.4/0.22ZGS Isolation Transformers25kVA0.40.22504ANIEC 60076110 kg375×320×370 mm
ZGS-30/0.48/0.208ZGS Isolation Transformers30kVA0.480.208604ANIEEE C57 / ANSI C84.1130 kg400×340×390 mm
ZGS-30/0.48/0.24ZGS Isolation Transformers30kVA0.480.24604ANIEEE C57 / ANSI C84.1130 kg400×340×390 mm
ZGS-30/0.22/0.12ZGS Isolation Transformers30kVA0.220.12504ANIEC 60076130 kg400×340×390 mm
ZGS-30/0.38/0.22ZGS Isolation Transformers30kVA0.380.22504ANIEC 60076130 kg400×340×390 mm
ZGS-30/0.66/0.38ZGS Isolation Transformers30kVA0.660.38504ANIEC 60076130 kg400×340×390 mm
ZGS-30/0.4/0.22ZGS Isolation Transformers30kVA0.40.22504ANIEC 60076130 kg400×340×390 mm
ZGS-40/0.48/0.208ZGS Isolation Transformers40kVA0.480.208604ANIEEE C57 / ANSI C84.1165 kg425×360×420 mm
ZGS-40/0.48/0.24ZGS Isolation Transformers40kVA0.480.24604ANIEEE C57 / ANSI C84.1165 kg425×360×420 mm
ZGS-40/0.22/0.12ZGS Isolation Transformers40kVA0.220.12504ANIEC 60076165 kg425×360×420 mm
ZGS-40/0.38/0.22ZGS Isolation Transformers40kVA0.380.22504ANIEC 60076165 kg425×360×420 mm
ZGS-40/0.66/0.38ZGS Isolation Transformers40kVA0.660.38504ANIEC 60076165 kg425×360×420 mm
ZGS-40/0.4/0.22ZGS Isolation Transformers40kVA0.40.22504ANIEC 60076165 kg425×360×420 mm
ZGS-50/0.48/0.208ZGS Isolation Transformers50kVA0.480.208604ANIEEE C57 / ANSI C84.1200 kg450×380×450 mm
ZGS-50/0.48/0.24ZGS Isolation Transformers50kVA0.480.24604ANIEEE C57 / ANSI C84.1200 kg450×380×450 mm
ZGS-50/0.22/0.12ZGS Isolation Transformers50kVA0.220.12504ANIEC 60076200 kg450×380×450 mm
ZGS-50/0.38/0.22ZGS Isolation Transformers50kVA0.380.22504ANIEC 60076200 kg450×380×450 mm
ZGS-50/0.66/0.38ZGS Isolation Transformers50kVA0.660.38504ANIEC 60076200 kg450×380×450 mm
ZGS-50/0.4/0.22ZGS Isolation Transformers50kVA0.40.22504ANIEC 60076200 kg450×380×450 mm
ZGS-63/0.48/0.208ZGS Isolation Transformers63kVA0.480.208604ANIEEE C57 / ANSI C84.1240 kg475×400×475 mm
ZGS-63/0.48/0.24ZGS Isolation Transformers63kVA0.480.24604ANIEEE C57 / ANSI C84.1240 kg475×400×475 mm
ZGS-63/0.22/0.12ZGS Isolation Transformers63kVA0.220.12504ANIEC 60076240 kg475×400×475 mm
ZGS-63/0.38/0.22ZGS Isolation Transformers63kVA0.380.22504ANIEC 60076240 kg475×400×475 mm
ZGS-63/0.66/0.38ZGS Isolation Transformers63kVA0.660.38504ANIEC 60076240 kg475×400×475 mm
ZGS-63/0.4/0.22ZGS Isolation Transformers63kVA0.40.22504ANIEC 60076240 kg475×400×475 mm
ZGS-80/0.48/0.208ZGS Isolation Transformers80kVA0.480.208604ANIEEE C57 / ANSI C84.1295 kg510×430×510 mm
ZGS-80/0.48/0.24ZGS Isolation Transformers80kVA0.480.24604ANIEEE C57 / ANSI C84.1295 kg510×430×510 mm
ZGS-80/0.22/0.12ZGS Isolation Transformers80kVA0.220.12504ANIEC 60076295 kg510×430×510 mm
ZGS-80/0.38/0.22ZGS Isolation Transformers80kVA0.380.22504ANIEC 60076295 kg510×430×510 mm
ZGS-80/0.66/0.38ZGS Isolation Transformers80kVA0.660.38504ANIEC 60076295 kg510×430×510 mm
ZGS-80/0.4/0.22ZGS Isolation Transformers80kVA0.40.22504ANIEC 60076295 kg510×430×510 mm
ZGS-100/0.48/0.208ZGS Isolation Transformers100kVA0.480.208604ANIEEE C57 / ANSI C84.1350 kg550×460×550 mm
ZGS-100/0.48/0.24ZGS Isolation Transformers100kVA0.480.24604ANIEEE C57 / ANSI C84.1350 kg550×460×550 mm
ZGS-100/0.22/0.12ZGS Isolation Transformers100kVA0.220.12504ANIEC 60076350 kg550×460×550 mm
ZGS-100/0.38/0.22ZGS Isolation Transformers100kVA0.380.22504ANIEC 60076350 kg550×460×550 mm
ZGS-100/0.66/0.38ZGS Isolation Transformers100kVA0.660.38504ANIEC 60076350 kg550×460×550 mm
ZGS-100/0.4/0.22ZGS Isolation Transformers100kVA0.40.22504ANIEC 60076350 kg550×460×550 mm
ZGS-125/0.48/0.208ZGS Isolation Transformers125kVA0.480.208606ANIEEE C57 / ANSI C84.1420 kg570×475×570 mm
ZGS-125/0.48/0.24ZGS Isolation Transformers125kVA0.480.24606ANIEEE C57 / ANSI C84.1420 kg570×475×570 mm
ZGS-125/0.22/0.12ZGS Isolation Transformers125kVA0.220.12506ANIEC 60076420 kg570×475×570 mm
ZGS-125/0.38/0.22ZGS Isolation Transformers125kVA0.380.22506ANIEC 60076420 kg570×475×570 mm
ZGS-125/0.66/0.38ZGS Isolation Transformers125kVA0.660.38506ANIEC 60076420 kg570×475×570 mm
ZGS-125/0.4/0.22ZGS Isolation Transformers125kVA0.40.22506ANIEC 60076420 kg570×475×570 mm
ZGS-160/0.48/0.208ZGS Isolation Transformers160kVA0.480.208606ANIEEE C57 / ANSI C84.1520 kg600×500×600 mm
ZGS-160/0.48/0.24ZGS Isolation Transformers160kVA0.480.24606ANIEEE C57 / ANSI C84.1520 kg600×500×600 mm
ZGS-160/0.22/0.12ZGS Isolation Transformers160kVA0.220.12506ANIEC 60076520 kg600×500×600 mm
ZGS-160/0.38/0.22ZGS Isolation Transformers160kVA0.380.22506ANIEC 60076520 kg600×500×600 mm
ZGS-160/0.66/0.38ZGS Isolation Transformers160kVA0.660.38506ANIEC 60076520 kg600×500×600 mm
ZGS-160/0.4/0.22ZGS Isolation Transformers160kVA0.40.22506ANIEC 60076520 kg600×500×600 mm
ZGS-200/0.48/0.208ZGS Isolation Transformers200kVA0.480.208606ANIEEE C57 / ANSI C84.1620 kg650×540×650 mm
ZGS-200/0.48/0.24ZGS Isolation Transformers200kVA0.480.24606ANIEEE C57 / ANSI C84.1620 kg650×540×650 mm
ZGS-200/0.22/0.12ZGS Isolation Transformers200kVA0.220.12506ANIEC 60076620 kg650×540×650 mm
ZGS-200/0.38/0.22ZGS Isolation Transformers200kVA0.380.22506ANIEC 60076620 kg650×540×650 mm
ZGS-200/0.66/0.38ZGS Isolation Transformers200kVA0.660.38506ANIEC 60076620 kg650×540×650 mm
ZGS-200/0.4/0.22ZGS Isolation Transformers200kVA0.40.22506ANIEC 60076620 kg650×540×650 mm
ZGS-250/0.48/0.208ZGS Isolation Transformers250kVA0.480.208606ANIEEE C57 / ANSI C84.1750 kg700×580×700 mm
ZGS-250/0.48/0.24ZGS Isolation Transformers250kVA0.480.24606ANIEEE C57 / ANSI C84.1750 kg700×580×700 mm
ZGS-250/0.22/0.12ZGS Isolation Transformers250kVA0.220.12506ANIEC 60076750 kg700×580×700 mm
ZGS-250/0.38/0.22ZGS Isolation Transformers250kVA0.380.22506ANIEC 60076750 kg700×580×700 mm
ZGS-250/0.66/0.38ZGS Isolation Transformers250kVA0.660.38506ANIEC 60076750 kg700×580×700 mm
ZGS-250/0.4/0.22ZGS Isolation Transformers250kVA0.40.22506ANIEC 60076750 kg700×580×700 mm
ZGS-315/0.48/0.208ZGS Isolation Transformers315kVA0.480.208606ANIEEE C57 / ANSI C84.1900 kg750×620×750 mm
ZGS-315/0.48/0.24ZGS Isolation Transformers315kVA0.480.24606ANIEEE C57 / ANSI C84.1900 kg750×620×750 mm
ZGS-315/0.22/0.12ZGS Isolation Transformers315kVA0.220.12506ANIEC 60076900 kg750×620×750 mm
ZGS-315/0.38/0.22ZGS Isolation Transformers315kVA0.380.22506ANIEC 60076900 kg750×620×750 mm
ZGS-315/0.66/0.38ZGS Isolation Transformers315kVA0.660.38506ANIEC 60076900 kg750×620×750 mm
ZGS-315/0.4/0.22ZGS Isolation Transformers315kVA0.40.22506ANIEC 60076900 kg750×620×750 mm
ZGS-400/0.48/0.208ZGS Isolation Transformers400kVA0.480.208606ANIEEE C57 / ANSI C84.11100 kg800×660×800 mm
ZGS-400/0.48/0.24ZGS Isolation Transformers400kVA0.480.24606ANIEEE C57 / ANSI C84.11100 kg800×660×800 mm
ZGS-400/0.22/0.12ZGS Isolation Transformers400kVA0.220.12506ANIEC 600761100 kg800×660×800 mm
ZGS-400/0.38/0.22ZGS Isolation Transformers400kVA0.380.22506ANIEC 600761100 kg800×660×800 mm
ZGS-400/0.66/0.38ZGS Isolation Transformers400kVA0.660.38506ANIEC 600761100 kg800×660×800 mm
ZGS-400/0.4/0.22ZGS Isolation Transformers400kVA0.40.22506ANIEC 600761100 kg800×660×800 mm
ZGS-500/0.48/0.208ZGS Isolation Transformers500kVA0.480.208606ANIEEE C57 / ANSI C84.11300 kg850×700×850 mm
ZGS-500/0.48/0.24ZGS Isolation Transformers500kVA0.480.24606ANIEEE C57 / ANSI C84.11300 kg850×700×850 mm
ZGS-500/0.22/0.12ZGS Isolation Transformers500kVA0.220.12506ANIEC 600761300 kg850×700×850 mm
ZGS-500/0.38/0.22ZGS Isolation Transformers500kVA0.380.22506ANIEC 600761300 kg850×700×850 mm
ZGS-500/0.66/0.38ZGS Isolation Transformers500kVA0.660.38506ANIEC 600761300 kg850×700×850 mm
ZGS-500/0.4/0.22ZGS Isolation Transformers500kVA0.40.22506ANIEC 600761300 kg850×700×850 mm
ZGS-630/0.48/0.208ZGS Isolation Transformers630kVA0.480.208606ANIEEE C57 / ANSI C84.11600 kg900×750×950 mm
ZGS-630/0.48/0.24ZGS Isolation Transformers630kVA0.480.24606ANIEEE C57 / ANSI C84.11600 kg900×750×950 mm
ZGS-630/0.22/0.12ZGS Isolation Transformers630kVA0.220.12506ANIEC 600761600 kg900×750×950 mm
ZGS-630/0.38/0.22ZGS Isolation Transformers630kVA0.380.22506ANIEC 600761600 kg900×750×950 mm
ZGS-630/0.66/0.38ZGS Isolation Transformers630kVA0.660.38506ANIEC 600761600 kg900×750×950 mm
ZGS-630/0.4/0.22ZGS Isolation Transformers630kVA0.40.22506ANIEC 600761600 kg900×750×950 mm
ZGS-800/0.48/0.208ZGS Isolation Transformers800kVA0.480.208606ANIEEE C57 / ANSI C84.11950 kg1000×820×1000 mm
ZGS-800/0.48/0.24ZGS Isolation Transformers800kVA0.480.24606ANIEEE C57 / ANSI C84.11950 kg1000×820×1000 mm
ZGS-800/0.22/0.12ZGS Isolation Transformers800kVA0.220.12506ANIEC 600761950 kg1000×820×1000 mm
ZGS-800/0.38/0.22ZGS Isolation Transformers800kVA0.380.22506ANIEC 600761950 kg1000×820×1000 mm
ZGS-800/0.66/0.38ZGS Isolation Transformers800kVA0.660.38506ANIEC 600761950 kg1000×820×1000 mm
ZGS-800/0.4/0.22ZGS Isolation Transformers800kVA0.40.22506ANIEC 600761950 kg1000×820×1000 mm
ZGS-1000/0.48/0.208ZGS Isolation Transformers1000kVA0.480.208606ANIEEE C57 / ANSI C84.12300 kg1050×880×1100 mm
ZGS-1000/0.48/0.24ZGS Isolation Transformers1000kVA0.480.24606ANIEEE C57 / ANSI C84.12300 kg1050×880×1100 mm
ZGS-1000/0.22/0.12ZGS Isolation Transformers1000kVA0.220.12506ANIEC 600762300 kg1050×880×1100 mm
ZGS-1000/0.38/0.22ZGS Isolation Transformers1000kVA0.380.22506ANIEC 600762300 kg1050×880×1100 mm
ZGS-1000/0.66/0.38ZGS Isolation Transformers1000kVA0.660.38506ANIEC 600762300 kg1050×880×1100 mm
ZGS-1000/0.4/0.22ZGS Isolation Transformers1000kVA0.40.22506ANIEC 600762300 kg1050×880×1100 mm
ZGS-0.1/10/0.4ZGS Isolation Transformers0.1kVA100.4504ANIEC 600760 kg90×80×95 mm
ZGS-0.1/6/0.4ZGS Isolation Transformers0.1kVA60.4504ANIEC 600760 kg90×80×95 mm
ZGS-0.2/10/0.4ZGS Isolation Transformers0.2kVA100.4504ANIEC 600765 kg100×90×110 mm
ZGS-0.2/6/0.4ZGS Isolation Transformers0.2kVA60.4504ANIEC 600765 kg100×90×110 mm
ZGS-0.3/10/0.4ZGS Isolation Transformers0.3kVA100.4504ANIEC 600765 kg110×100×120 mm
ZGS-0.3/6/0.4ZGS Isolation Transformers0.3kVA60.4504ANIEC 600765 kg110×100×120 mm
ZGS-0.5/10/0.4ZGS Isolation Transformers0.5kVA100.4504ANIEC 600765 kg120×110×130 mm
ZGS-0.5/6/0.4ZGS Isolation Transformers0.5kVA60.4504ANIEC 600765 kg120×110×130 mm
ZGS-1/10/0.4ZGS Isolation Transformers1kVA100.4504ANIEC 6007610 kg140×130×150 mm
ZGS-1/6/0.4ZGS Isolation Transformers1kVA60.4504ANIEC 6007610 kg140×130×150 mm
ZGS-1.5/10/0.4ZGS Isolation Transformers1.5kVA100.4504ANIEC 6007615 kg160×140×170 mm
ZGS-1.5/6/0.4ZGS Isolation Transformers1.5kVA60.4504ANIEC 6007615 kg160×140×170 mm
ZGS-2/10/0.4ZGS Isolation Transformers2kVA100.4504ANIEC 6007615 kg170×150×180 mm
ZGS-2/6/0.4ZGS Isolation Transformers2kVA60.4504ANIEC 6007615 kg170×150×180 mm
ZGS-3/10/0.4ZGS Isolation Transformers3kVA100.4504ANIEC 6007620 kg190×170×200 mm
ZGS-3/6/0.4ZGS Isolation Transformers3kVA60.4504ANIEC 6007620 kg190×170×200 mm
ZGS-4/10/0.4ZGS Isolation Transformers4kVA100.4504ANIEC 6007625 kg205×180×215 mm
ZGS-4/6/0.4ZGS Isolation Transformers4kVA60.4504ANIEC 6007625 kg205×180×215 mm
ZGS-5/10/0.4ZGS Isolation Transformers5kVA100.4504ANIEC 6007630 kg220×190×230 mm
ZGS-5/6/0.4ZGS Isolation Transformers5kVA60.4504ANIEC 6007630 kg220×190×230 mm
ZGS-6.3/10/0.4ZGS Isolation Transformers6.3kVA100.4504ANIEC 6007640 kg235×205×245 mm
ZGS-6.3/6/0.4ZGS Isolation Transformers6.3kVA60.4504ANIEC 6007640 kg235×205×245 mm
ZGS-8/10/0.4ZGS Isolation Transformers8kVA100.4504ANIEC 6007645 kg255×225×265 mm
ZGS-8/6/0.4ZGS Isolation Transformers8kVA60.4504ANIEC 6007645 kg255×225×265 mm
ZGS-10/10/0.4ZGS Isolation Transformers10kVA100.4504ANIEC 6007655 kg280×240×290 mm
ZGS-10/6/0.4ZGS Isolation Transformers10kVA60.4504ANIEC 6007655 kg280×240×290 mm
ZGS-15/10/0.4ZGS Isolation Transformers15kVA100.4504ANIEC 6007675 kg320×270×320 mm
ZGS-15/6/0.4ZGS Isolation Transformers15kVA60.4504ANIEC 6007675 kg320×270×320 mm
ZGS-20/10/0.4ZGS Isolation Transformers20kVA100.4504ANIEC 6007690 kg350×300×350 mm
ZGS-20/6/0.4ZGS Isolation Transformers20kVA60.4504ANIEC 6007690 kg350×300×350 mm
ZGS-25/10/0.4ZGS Isolation Transformers25kVA100.4504ANIEC 60076110 kg375×320×370 mm
ZGS-25/6/0.4ZGS Isolation Transformers25kVA60.4504ANIEC 60076110 kg375×320×370 mm
ZGS-30/10/0.4ZGS Isolation Transformers30kVA100.4504ANIEC 60076130 kg400×340×390 mm
ZGS-30/6/0.4ZGS Isolation Transformers30kVA60.4504ANIEC 60076130 kg400×340×390 mm
ZGS-40/10/0.4ZGS Isolation Transformers40kVA100.4504ANIEC 60076165 kg425×360×420 mm
ZGS-40/6/0.4ZGS Isolation Transformers40kVA60.4504ANIEC 60076165 kg425×360×420 mm
ZGS-50/10/0.4ZGS Isolation Transformers50kVA100.4504ANIEC 60076200 kg450×380×450 mm
ZGS-50/6/0.4ZGS Isolation Transformers50kVA60.4504ANIEC 60076200 kg450×380×450 mm
ZGS-63/10/0.4ZGS Isolation Transformers63kVA100.4504ANIEC 60076240 kg475×400×475 mm
ZGS-63/6/0.4ZGS Isolation Transformers63kVA60.4504ANIEC 60076240 kg475×400×475 mm
ZGS-80/10/0.4ZGS Isolation Transformers80kVA100.4504ANIEC 60076295 kg510×430×510 mm
ZGS-80/6/0.4ZGS Isolation Transformers80kVA60.4504ANIEC 60076295 kg510×430×510 mm
ZGS-100/10/0.4ZGS Isolation Transformers100kVA100.4504ANIEC 60076350 kg550×460×550 mm
ZGS-100/6/0.4ZGS Isolation Transformers100kVA60.4504ANIEC 60076350 kg550×460×550 mm
ZGS-125/10/0.4ZGS Isolation Transformers125kVA100.4506ANIEC 60076420 kg570×475×570 mm
ZGS-125/6/0.4ZGS Isolation Transformers125kVA60.4506ANIEC 60076420 kg570×475×570 mm
ZGS-160/10/0.4ZGS Isolation Transformers160kVA100.4506ANIEC 60076520 kg600×500×600 mm
ZGS-160/6/0.4ZGS Isolation Transformers160kVA60.4506ANIEC 60076520 kg600×500×600 mm
ZGS-200/10/0.4ZGS Isolation Transformers200kVA100.4506ANIEC 60076620 kg650×540×650 mm
ZGS-200/6/0.4ZGS Isolation Transformers200kVA60.4506ANIEC 60076620 kg650×540×650 mm
ZGS-250/10/0.4ZGS Isolation Transformers250kVA100.4506ANIEC 60076750 kg700×580×700 mm
ZGS-250/6/0.4ZGS Isolation Transformers250kVA60.4506ANIEC 60076750 kg700×580×700 mm
ZGS-315/10/0.4ZGS Isolation Transformers315kVA100.4506ANIEC 60076900 kg750×620×750 mm
ZGS-315/6/0.4ZGS Isolation Transformers315kVA60.4506ANIEC 60076900 kg750×620×750 mm
ZGS-400/10/0.4ZGS Isolation Transformers400kVA100.4506ANIEC 600761100 kg800×660×800 mm
ZGS-400/6/0.4ZGS Isolation Transformers400kVA60.4506ANIEC 600761100 kg800×660×800 mm
ZGS-500/10/0.4ZGS Isolation Transformers500kVA100.4506ANIEC 600761300 kg850×700×850 mm
ZGS-500/6/0.4ZGS Isolation Transformers500kVA60.4506ANIEC 600761300 kg850×700×850 mm
ZGS-630/10/0.4ZGS Isolation Transformers630kVA100.4506ANIEC 600761600 kg900×750×950 mm
ZGS-630/6/0.4ZGS Isolation Transformers630kVA60.4506ANIEC 600761600 kg900×750×950 mm
ZGS-800/10/0.4ZGS Isolation Transformers800kVA100.4506ANIEC 600761950 kg1000×820×1000 mm
ZGS-800/6/0.4ZGS Isolation Transformers800kVA60.4506ANIEC 600761950 kg1000×820×1000 mm
ZGS-1000/10/0.4ZGS Isolation Transformers1000kVA100.4506ANIEC 600762300 kg1050×880×1100 mm
ZGS-1000/6/0.4ZGS Isolation Transformers1000kVA60.4506ANIEC 600762300 kg1050×880×1100 mm

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
2 · Your price
EXW (FOB Qingdao)
$10
Range $10 ~ $118%)
Price Breakdown
Base price (interpolation)$10
× Product factor×1.0000
× Country factor×1.0000
× Copper-linked factor×1.0000
+ Options / accessories$0
Shipping quoted separately per destination port.

Aluminum winding — no copper linkage

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.