Cable Branch Boxes with Load Break Switch — Ring Main Function

Cable branch boxes with a built-in load break switch combine cable distribution with switching capability, allowing each outgoing feeder to be isolated and switched for ring-main operation. Rated 12–24 kV, 630A, they use SF6 or vacuum load break switches for maintenance-free switching in urban distribution networks and ring main configurations.

Applications

1

Urban ring-main distribution networks

2

Feeder sectionalizing and isolation

3

Municipal grid reconfiguration

4

Industrial and renewable plant distribution

Key Features

  • Integrated SF6 or vacuum load break switch per feeder
  • Ring-main switching capability with fault isolation
  • 630A rated main busbar for 12–24 kV networks
  • Compact pad-mounted or surface-mounted enclosure
  • Manual or motorized operating mechanism options
  • Configurable feeder count for loop networks

Specifications Range

All specifications and dimensions can be customized upon request

Key parametersModel Range
Rated Voltage12
Rated Current630 A
Main Circuits4
Short-time Withstand Current20 kA
Protection LevelIP4X
StandardGB3906, IEC 62271-200
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)Current (A)Frequency (Hz)InsulationStandardWeightDimensions
FZX-630-1WLoad Break Switch Branch Boxes12630-—GB3906, IEC 62271-200101 kg2270×1765×3025 mm
FZX-630-2WLoad Break Switch Branch Boxes12630-—GB3906, IEC 62271-200101 kg2270×1765×3025 mm
FZX-630-3WLoad Break Switch Branch Boxes12630-—GB3906, IEC 62271-200101 kg2270×1765×3025 mm
FZX-630-4WLoad Break Switch Branch Boxes12630-—GB3906, IEC 62271-200101 kg2270×1765×3025 mm

Product Drawing

Cable Branch Box - FZX-630-3W

APPEARANCE — CABLE BRANCH CABINET
CABLE BRANCH BOXFZX-630-3W
BRANCH WIRING — 1-IN N-OUT
CABLE BRANCH — 1 IN / N OUTINCOMINGOUT 1OUT 2OUT 3OUT 4FZX-630-3W
FEEDER CONFIGURATION
FEEDER CONFIGURATION — OUTGOINGmain busbarF1F2F3F4F5F6FZX-630-3W

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Switching

Specify manual or motorized operation based on automation needs.

2

Feeders

Choose the outgoing feeder count to match the loop configuration.

3

Insulation

Select SF6 or vacuum switch per project preference and environment.

- Frequently Asked Questions

Why add a load break switch to a branch box?

A load break switch lets each feeder be switched and isolated for maintenance or fault clearing, enabling ring-main operation where a cable fault can be isolated while the rest of the loop stays energized.

SF6 or vacuum switch?

Both are maintenance-free; SF6 offers compact gas insulation, vacuum offers high switching endurance. Either is suitable for 12–24 kV distribution.

What is the standard rating?

Typically 630A, 12–24 kV, with load break switching duty.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(3)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.