QDTB® Transformer

Product Search

Find the right transformer for your needs

SF6 Gas Insulated Branch Boxes Series Cable Branch Boxes & Switching Stations

3 Models available

SF6 Gas Insulated Branch Boxes Cable Branch Boxes & Switching Stations

Images are for illustration purposes only

SF6 Gas Insulated Branch Boxes — Gas Insulated Junction

SF6 gas insulated cable branch boxes use sealed SF6 insulation for compact, maintenance-free medium-voltage cable junction and switching. Rated 12–24 kV, 630A, for underground distribution where sealed gas insulation provides immunity to moisture and contamination.

Applications

1

Underground distribution junctions

2

Harsh and humid environments

3

Urban network sectionalizing

4

Industrial medium-voltage distribution

Key Features

  • Sealed SF6 gas insulation
  • Maintenance-free operation
  • 12–24 kV, 630A
  • Compact and moisture-immune
  • Load-break and fused options
  • Suitable for underground and harsh sites

Specifications Range

All specifications and dimensions can be customized upon request

Key parametersModel Range
Rated Voltage24
Rated Current630 A
Main Circuits4
Short-time Withstand Current20 kA
Protection LevelIP4X
StandardGB3906, IEC 62271-200
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)Current (A)Frequency (Hz)InsulationStandardWeightDimensions
SFB-630-1WSF6 Gas Insulated Branch Boxes24630-SF6 gasGB3906, IEC 62271-200124 kg2270×1765×2775 mm
SFB-630-2WSF6 Gas Insulated Branch Boxes24630-SF6 gasGB3906, IEC 62271-200124 kg2270×1765×2775 mm
SFB-630-3WSF6 Gas Insulated Branch Boxes24630-SF6 gasGB3906, IEC 62271-200124 kg2270×1765×2775 mm

Product Drawing

Cable Branch Box - SFB-630-2W

APPEARANCE — CABLE BRANCH CABINET
CABLE BRANCH BOXSFB-630-2W
BRANCH WIRING — 1-IN N-OUT
CABLE BRANCH — 1 IN / N OUTINCOMINGOUT 1OUT 2OUT 3OUT 4SFB-630-2W
FEEDER CONFIGURATION
FEEDER CONFIGURATION — OUTGOINGmain busbarF1F2F3F4F5F6SFB-630-2W

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Voltage

Match 12–24 kV system voltage.

2

Environment

Choose SF6 for harsh, humid or underground installations.

- Frequently Asked Questions

What is an SF6 gas insulated branch box?

An SF6 branch box uses sealed SF6 gas insulation for compact, maintenance-free cable junction and switching, immune to moisture and contamination.

Why SF6 insulation?

SF6 gas insulation allows compact construction and maintenance-free operation in harsh or humid environments.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(3)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.