Product Search
Find the right transformer for your needs
AC-Cable Series — XLPE Power Cables
6 Models available · Cables, Trays, Grounding & Fasteners
XLPE-insulated 0.6/1 kV power cables carrying inverter output to switchboards and the grid connection point.
Model Number Breakdown
- 0.6/1 kV rating
- XLPE insulation
- Copper/aluminium core
- Armoured options

Specifications Range
All specifications and dimensions can be customized upon request
| Key parameters | Model Range |
|---|---|
| Rated Voltage | 0.6 kV |
| Cross-Section | 10 mm², 25 mm², 50 mm², 95 mm², 150 mm², 240 mm² |
| Cable Type | YJV |
| Type | AC cable |
| Key Spec | 10 mm² · 0.6 kV, 25 mm² · 0.6 kV, 50 mm² · 0.6 kV, 95 mm² · 0.6 kV, 150 mm² · 0.6 kV, 240 mm² · 0.6 kV |
| Standard | GB/T 12706 |
⚙How It Works
AC power cable carries the inverter's output to the switchboard and the grid connection point. XLPE insulation gives it excellent thermal and dielectric performance, and the 0.6/1 kV rating covers standard low-voltage distribution. Correct sizing keeps voltage drop within code limits and matches the upstream breaker rating, so the cable is protected and the plant operates safely.
▦Structure & Composition
The YJV cable has a copper or aluminium conductor, XLPE insulation, a metallic screen or armour where required, and a PVC outer sheath. It is sold by core count and cross-section (3×10 mm² up to 3×240 mm²) to match the inverter output current, with armoured variants for buried or mechanically exposed runs.
Model Range
| Model | Type | Key Spec | Standard | Reference Price |
|---|---|---|---|---|
| QD-YJV-3X10 | AC cable | 10 mm² · 0.6 kV | GB/T 12706 | … |
| QD-YJV-3X25 | AC cable | 25 mm² · 0.6 kV | GB/T 12706 | … |
| QD-YJV-3X50 | AC cable | 50 mm² · 0.6 kV | GB/T 12706 | … |
| QD-YJV-3X95 | AC cable | 95 mm² · 0.6 kV | GB/T 12706 | … |
| QD-YJV-3X150 | AC cable | 150 mm² · 0.6 kV | GB/T 12706 | … |
| QD-YJV-3X240 | AC cable | 240 mm² · 0.6 kV | GB/T 12706 | … |
Applications
Selection Guide
- Size the cross-section to the inverter output current and run length, keeping voltage drop within code limits.
- Choose armoured cable for buried runs or where mechanical damage is possible.
- Match the cable's current rating to the upstream breaker so the breaker protects the cable.
Frequently Asked Questions
What cable size do I need?
The cross-section depends on the inverter output current and run length, and must match the upstream breaker rating.
Copper or aluminium conductor?
Copper carries more current per size; aluminium is lighter and cheaper for long, large runs.
When is armoured cable required?
For buried runs or where the cable is exposed to mechanical damage, armoured construction protects the insulation.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
| Base price (interpolation) | $0 |
| × Product factor | ×1.0000 |
| × Country factor | ×1.0000 |
| × Copper-linked factor | ×1.0000 |
| + Options / accessories | $0 |
Complete equipment — no winding copper linkage
Reference prices are for estimation only and do not constitute a formal offer.
We will reply with your latest quote instantly.
Solar System Configurator
Size your solar array, storage and balance-of-system, and get an instant bill of materials.