AC-Cable Series — XLPE Power Cables

6 Models available · Cables, Trays, Grounding & Fasteners

XLPE-insulated 0.6/1 kV power cables carrying inverter output to switchboards and the grid connection point.

Model Number Breakdown

YJVXLPE insulated cable
3X10Cores x cross-section (mm²)
  • 0.6/1 kV rating
  • XLPE insulation
  • Copper/aluminium core
  • Armoured options
AC-Cable Cables, Trays, Grounding & Fasteners

Specifications Range

All specifications and dimensions can be customized upon request

Key parametersModel Range
Rated Voltage0.6 kV
Cross-Section10 mm², 25 mm², 50 mm², 95 mm², 150 mm², 240 mm²
Cable TypeYJV
TypeAC cable
Key Spec10 mm² · 0.6 kV, 25 mm² · 0.6 kV, 50 mm² · 0.6 kV, 95 mm² · 0.6 kV, 150 mm² · 0.6 kV, 240 mm² · 0.6 kV
StandardGB/T 12706

How It Works

AC power cable carries the inverter's output to the switchboard and the grid connection point. XLPE insulation gives it excellent thermal and dielectric performance, and the 0.6/1 kV rating covers standard low-voltage distribution. Correct sizing keeps voltage drop within code limits and matches the upstream breaker rating, so the cable is protected and the plant operates safely.

Structure & Composition

The YJV cable has a copper or aluminium conductor, XLPE insulation, a metallic screen or armour where required, and a PVC outer sheath. It is sold by core count and cross-section (3×10 mm² up to 3×240 mm²) to match the inverter output current, with armoured variants for buried or mechanically exposed runs.

AC Distribution & GroundingInverterCable trayAC cableGridgrounding rod
TN-S Distribution & EarthingL1L2L3NPEGridLoads3P+N+PESeparate N and PE (TN-S)

Model Range

ModelTypeKey SpecStandardReference Price
QD-YJV-3X10AC cable10 mm² · 0.6 kVGB/T 12706
QD-YJV-3X25AC cable25 mm² · 0.6 kVGB/T 12706
QD-YJV-3X50AC cable50 mm² · 0.6 kVGB/T 12706
QD-YJV-3X95AC cable95 mm² · 0.6 kVGB/T 12706
QD-YJV-3X150AC cable150 mm² · 0.6 kVGB/T 12706
QD-YJV-3X240AC cable240 mm² · 0.6 kVGB/T 12706

Applications

1Inverter output
2AC distribution
3Switchboard feeds
4Grid connection

Selection Guide

  • Size the cross-section to the inverter output current and run length, keeping voltage drop within code limits.
  • Choose armoured cable for buried runs or where mechanical damage is possible.
  • Match the cable's current rating to the upstream breaker so the breaker protects the cable.
Ampacity vs Conductor Size95 mm²Cross-section (mm²)Ampacity (A)

Frequently Asked Questions

Q

What cable size do I need?

The cross-section depends on the inverter output current and run length, and must match the upstream breaker rating.

Q

Copper or aluminium conductor?

Copper carries more current per size; aluminium is lighter and cheaper for long, large runs.

Q

When is armoured cable required?

For buried runs or where the cable is exposed to mechanical damage, armoured construction protects the insulation.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
2 · Your price
EXW (FOB Qingdao)
$0
Range $0 ~ $08%)
Price Breakdown
Base price (interpolation)$0
× Product factor×1.0000
× Country factor×1.0000
× Copper-linked factor×1.0000
+ Options / accessories$0
Shipping quoted separately per destination port.

Complete equipment — no winding copper linkage

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Solar System Configurator

Size your solar array, storage and balance-of-system, and get an instant bill of materials.

Need help?

All specifications and dimensions can be customized upon request

Contact Us