SCB13 Series - Energy-Efficient Cast Resin Dry-Type Transformers (Level 3 Efficiency)
The SCB13 series is an energy-efficient variant of cast resin dry-type transformers, meeting Level 3 energy efficiency standards with reduced no-load losses. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, Class F insulation with 65 K temperature rise, IP00–IP31 enclosure (IP42–IP66 available on request). Suitable for indoor substations, data centers, commercial buildings, industrial plants, and solar/wind farms.
Model Number Breakdown
Key Features
- Level 3 energy efficiency rating
- Reduced no-load losses compared to standard models
- Cast resin insulation for enhanced safety
- Ideal for energy-conscious applications
Applications
- Green buildings
- Energy-efficient facilities
- Commercial complexes
- Educational institutions
TECHNICAL DRAWING
Model: SCB13-250/10/0.48 | Type: Dry-type transformer | Capacity: 250 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 10, 6, 35, 0.48 |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 6, 7 |
| Cooling | AN/AF, AF |
| Efficiency | Class 3 |
| Standard | IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | F (155°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤36 dB(A), ≤37 dB(A), ≤38 dB(A), ≤39 dB(A), ≤40 dB(A), ≤41 dB(A)… |
| Tap Changer | ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap |
| No-load loss | 61–4472 W |
| Load loss | 380–28760 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| SCB13-10/10/0.4 | 10kVA | 10 | 0.4 | 238 kg | 607×477×472 mm | |
| SCB13-10/6/0.4 | 10kVA | 6 | 0.4 | 238 kg | 607×477×472 mm | |
| SCB13-10/35/0.4 | 10kVA | 35 | 0.4 | 238 kg | 607×477×472 mm | |
| SCB13-10/10/0.48 | 10kVA | 10 | 0.48 | 238 kg | 607×477×472 mm | |
| SCB13-10/10/0.22 | 10kVA | 10 | 0.22 | 238 kg | 607×477×472 mm | |
| SCB13-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 238 kg | 607×477×472 mm | |
| SCB13-15/10/0.4 | 15kVA | 10 | 0.4 | 270 kg | 642×501×501 mm | |
| SCB13-15/6/0.4 | 15kVA | 6 | 0.4 | 270 kg | 642×501×501 mm | |
| SCB13-15/35/0.4 | 15kVA | 35 | 0.4 | 270 kg | 642×501×501 mm | |
| SCB13-15/10/0.48 | 15kVA | 10 | 0.48 | 270 kg | 642×501×501 mm | |
| SCB13-15/10/0.22 | 15kVA | 10 | 0.22 | 270 kg | 642×501×501 mm | |
| SCB13-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 270 kg | 642×501×501 mm | |
| SCB13-20/10/0.4 | 20kVA | 10 | 0.4 | 302 kg | 676×525×531 mm | |
| SCB13-20/6/0.4 | 20kVA | 6 | 0.4 | 302 kg | 676×525×531 mm | |
| SCB13-20/35/0.4 | 20kVA | 35 | 0.4 | 302 kg | 676×525×531 mm | |
| SCB13-20/10/0.48 | 20kVA | 10 | 0.48 | 302 kg | 676×525×531 mm | |
| SCB13-20/10/0.22 | 20kVA | 10 | 0.22 | 302 kg | 676×525×531 mm | |
| SCB13-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 302 kg | 676×525×531 mm | |
| SCB13-25/10/0.4 | 25kVA | 10 | 0.4 | 334 kg | 720×558×554 mm | |
| SCB13-25/6/0.4 | 25kVA | 6 | 0.4 | 334 kg | 720×558×554 mm | |
| SCB13-25/35/0.4 | 25kVA | 35 | 0.4 | 334 kg | 720×558×554 mm | |
| SCB13-25/10/0.48 | 25kVA | 10 | 0.48 | 334 kg | 720×558×554 mm | |
| SCB13-25/10/0.22 | 25kVA | 10 | 0.22 | 334 kg | 720×558×554 mm | |
| SCB13-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 334 kg | 720×558×554 mm | |
| SCB13-30/10/0.4 | 30kVA | 10 | 0.4 | 365 kg | 763×592×578 mm | |
| SCB13-30/6/0.4 | 30kVA | 6 | 0.4 | 365 kg | 763×592×578 mm | |
| SCB13-30/35/0.4 | 30kVA | 35 | 0.4 | 365 kg | 763×592×578 mm | |
| SCB13-30/10/0.48 | 30kVA | 10 | 0.48 | 365 kg | 763×592×578 mm | |
| SCB13-30/10/0.22 | 30kVA | 10 | 0.22 | 365 kg | 763×592×578 mm | |
| SCB13-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 365 kg | 763×592×578 mm | |
| SCB13-40/10/0.4 | 40kVA | 10 | 0.4 | 405 kg | 815×659×613 mm | |
| SCB13-40/6/0.4 | 40kVA | 6 | 0.4 | 405 kg | 815×659×613 mm | |
| SCB13-40/35/0.4 | 40kVA | 35 | 0.4 | 405 kg | 815×659×613 mm | |
| SCB13-40/10/0.48 | 40kVA | 10 | 0.48 | 405 kg | 815×659×613 mm | |
| SCB13-40/10/0.22 | 40kVA | 10 | 0.22 | 405 kg | 815×659×613 mm | |
| SCB13-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 405 kg | 815×659×613 mm | |
| SCB13-50/10/0.4 | 50kVA | 10 | 0.4 | 445 kg | 867×725×649 mm | |
| SCB13-50/6/0.4 | 50kVA | 6 | 0.4 | 445 kg | 867×725×649 mm | |
| SCB13-50/35/0.4 | 50kVA | 35 | 0.4 | 445 kg | 867×725×649 mm | |
| SCB13-50/10/0.48 | 50kVA | 10 | 0.48 | 445 kg | 867×725×649 mm | |
| SCB13-50/10/0.22 | 50kVA | 10 | 0.22 | 445 kg | 867×725×649 mm | |
| SCB13-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 445 kg | 867×725×649 mm | |
| SCB13-63/10/0.4 | 63kVA | 10 | 0.4 | 492.5 kg | 884×740×669 mm | |
| SCB13-63/6/0.4 | 63kVA | 6 | 0.4 | 492.5 kg | 884×740×669 mm | |
| SCB13-63/35/0.4 | 63kVA | 35 | 0.4 | 492.5 kg | 884×740×669 mm | |
| SCB13-63/10/0.48 | 63kVA | 10 | 0.48 | 492.5 kg | 884×740×669 mm | |
| SCB13-63/10/0.22 | 63kVA | 10 | 0.22 | 492.5 kg | 884×740×669 mm | |
| SCB13-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 492.5 kg | 884×740×669 mm | |
| SCB13-80/10/0.4 | 80kVA | 10 | 0.4 | 556 kg | 910×764×696 mm | |
| SCB13-80/6/0.4 | 80kVA | 6 | 0.4 | 556 kg | 910×764×696 mm | |
| SCB13-80/35/0.4 | 80kVA | 35 | 0.4 | 556 kg | 910×764×696 mm | |
| SCB13-80/10/0.48 | 80kVA | 10 | 0.48 | 556 kg | 910×764×696 mm | |
| SCB13-80/10/0.22 | 80kVA | 10 | 0.22 | 556 kg | 910×764×696 mm | |
| SCB13-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 556 kg | 910×764×696 mm | |
| SCB13-100/10/0.4 | 100kVA | 10 | 0.4 | 635.5 kg | 954×764×737 mm | |
| SCB13-100/6/0.4 | 100kVA | 6 | 0.4 | 635.5 kg | 954×764×737 mm | |
| SCB13-100/35/0.4 | 100kVA | 35 | 0.4 | 635.5 kg | 954×764×737 mm | |
| SCB13-100/10/0.48 | 100kVA | 10 | 0.48 | 635.5 kg | 954×764×737 mm | |
| SCB13-100/10/0.22 | 100kVA | 10 | 0.22 | 635.5 kg | 954×764×737 mm | |
| SCB13-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 635.5 kg | 954×764×737 mm | |
| SCB13-125/10/0.4 | 125kVA | 10 | 0.4 | 715 kg | 997×783×767 mm | |
| SCB13-125/6/0.4 | 125kVA | 6 | 0.4 | 715 kg | 997×783×767 mm | |
| SCB13-125/35/0.4 | 125kVA | 35 | 0.4 | 715 kg | 997×783×767 mm | |
| SCB13-125/10/0.48 | 125kVA | 10 | 0.48 | 715 kg | 997×783×767 mm | |
| SCB13-125/10/0.22 | 125kVA | 10 | 0.22 | 715 kg | 997×783×767 mm | |
| SCB13-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 715 kg | 997×783×767 mm | |
| SCB13-160/10/0.4 | 160kVA | 10 | 0.4 | 834 kg | 1041×811×796 mm | |
| SCB13-160/6/0.4 | 160kVA | 6 | 0.4 | 834 kg | 1041×811×796 mm | |
| SCB13-160/35/0.4 | 160kVA | 35 | 0.4 | 834 kg | 1041×811×796 mm | |
| SCB13-160/10/0.48 | 160kVA | 10 | 0.48 | 834 kg | 1041×811×796 mm | |
| SCB13-160/10/0.22 | 160kVA | 10 | 0.22 | 834 kg | 1041×811×796 mm | |
| SCB13-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 834 kg | 1041×811×796 mm | |
| SCB13-200/10/0.4 | 200kVA | 10 | 0.4 | 953 kg | 1084×840×826 mm | |
| SCB13-200/6/0.4 | 200kVA | 6 | 0.4 | 953 kg | 1084×840×826 mm | |
| SCB13-200/35/0.4 | 200kVA | 35 | 0.4 | 953 kg | 1084×840×826 mm | |
| SCB13-200/10/0.48 | 200kVA | 10 | 0.48 | 953 kg | 1084×840×826 mm | |
| SCB13-200/10/0.22 | 200kVA | 10 | 0.22 | 953 kg | 1084×840×826 mm | |
| SCB13-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 953 kg | 1084×840×826 mm | |
| SCB13-250/10/0.4 | 250kVA | 10 | 0.4 | 1072 kg | 1127×859×855 mm | |
| SCB13-250/6/0.4 | 250kVA | 6 | 0.4 | 1072 kg | 1127×859×855 mm | |
| SCB13-250/35/0.4 | 250kVA | 35 | 0.4 | 1072 kg | 1127×859×855 mm | |
| SCB13-250/10/0.48 | 250kVA | 10 | 0.48 | 1072 kg | 1127×859×855 mm | |
| SCB13-250/10/0.22 | 250kVA | 10 | 0.22 | 1072 kg | 1127×859×855 mm | |
| SCB13-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 1072 kg | 1127×859×855 mm | |
| SCB13-315/10/0.4 | 315kVA | 10 | 0.4 | 1231 kg | 1171×907×885 mm | |
| SCB13-315/6/0.4 | 315kVA | 6 | 0.4 | 1231 kg | 1171×907×885 mm | |
| SCB13-315/35/0.4 | 315kVA | 35 | 0.4 | 1231 kg | 1171×907×885 mm | |
| SCB13-315/10/0.48 | 315kVA | 10 | 0.48 | 1231 kg | 1171×907×885 mm | |
| SCB13-315/10/0.22 | 315kVA | 10 | 0.22 | 1231 kg | 1171×907×885 mm | |
| SCB13-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1231 kg | 1171×907×885 mm | |
| SCB13-400/10/0.4 | 400kVA | 10 | 0.4 | 1427 kg | 1110×900×900 mm | |
| SCB13-400/6/0.4 | 400kVA | 6 | 0.4 | 1427 kg | 1110×900×900 mm | |
| SCB13-400/35/0.4 | 400kVA | 35 | 0.4 | 1427 kg | 1110×900×900 mm | |
| SCB13-400/10/0.48 | 400kVA | 10 | 0.48 | 1427 kg | 1110×900×900 mm | |
| SCB13-400/10/0.22 | 400kVA | 10 | 0.22 | 1427 kg | 1110×900×900 mm | |
| SCB13-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1427 kg | 1110×900×900 mm | |
| SCB13-500/10/0.4 | 500kVA | 10 | 0.4 | 1580 kg | 1160×920×980 mm | |
| SCB13-500/6/0.4 | 500kVA | 6 | 0.4 | 1580 kg | 1160×920×980 mm | |
| SCB13-500/35/0.4 | 500kVA | 35 | 0.4 | 1580 kg | 1160×920×980 mm | |
| SCB13-500/10/0.48 | 500kVA | 10 | 0.48 | 1580 kg | 1160×920×980 mm | |
| SCB13-500/10/0.22 | 500kVA | 10 | 0.22 | 1580 kg | 1160×920×980 mm | |
| SCB13-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1580 kg | 1160×920×980 mm | |
| SCB13-630/10/0.4 | 630kVA | 10 | 0.4 | 1836 kg | 1330×1050×950 mm | |
| SCB13-630/6/0.4 | 630kVA | 6 | 0.4 | 1836 kg | 1330×1050×950 mm | |
| SCB13-630/35/0.4 | 630kVA | 35 | 0.4 | 1836 kg | 1330×1050×950 mm | |
| SCB13-630/10/0.48 | 630kVA | 10 | 0.48 | 1836 kg | 1330×1050×950 mm | |
| SCB13-630/10/0.22 | 630kVA | 10 | 0.22 | 1836 kg | 1330×1050×950 mm | |
| SCB13-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 1836 kg | 1330×1050×950 mm | |
| SCB13-800/10/0.4 | 800kVA | 10 | 0.4 | 2149 kg | 1390×1050×1040 mm | |
| SCB13-800/6/0.4 | 800kVA | 6 | 0.4 | 2149 kg | 1390×1050×1040 mm | |
| SCB13-800/35/0.4 | 800kVA | 35 | 0.4 | 2149 kg | 1390×1050×1040 mm | |
| SCB13-800/10/0.48 | 800kVA | 10 | 0.48 | 2149 kg | 1390×1050×1040 mm | |
| SCB13-800/10/0.22 | 800kVA | 10 | 0.22 | 2149 kg | 1390×1050×1040 mm | |
| SCB13-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 2149 kg | 1390×1050×1040 mm | |
| SCB13-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2651 kg | 1410×1050×1120 mm | |
| SCB13-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2651 kg | 1410×1050×1120 mm | |
| SCB13-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2651 kg | 1410×1050×1120 mm | |
| SCB13-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2651 kg | 1410×1050×1120 mm | |
| SCB13-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2651 kg | 1410×1050×1120 mm | |
| SCB13-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2651 kg | 1410×1050×1120 mm | |
| SCB13-1250/10/0.4 | 1250kVA | 10 | 0.4 | 2854 kg | 1450×1100×1150 mm | |
| SCB13-1250/6/0.4 | 1250kVA | 6 | 0.4 | 2854 kg | 1450×1100×1150 mm | |
| SCB13-1250/35/0.4 | 1250kVA | 35 | 0.4 | 2854 kg | 1450×1100×1150 mm | |
| SCB13-1250/10/0.48 | 1250kVA | 10 | 0.48 | 2854 kg | 1450×1100×1150 mm | |
| SCB13-1250/10/0.22 | 1250kVA | 10 | 0.22 | 2854 kg | 1450×1100×1150 mm | |
| SCB13-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 2854 kg | 1450×1100×1150 mm | |
| SCB13-1600/10/0.4 | 1600kVA | 10 | 0.4 | 3257 kg | 1561×1145×1209 mm | |
| SCB13-1600/6/0.4 | 1600kVA | 6 | 0.4 | 3257 kg | 1561×1145×1209 mm | |
| SCB13-1600/35/0.4 | 1600kVA | 35 | 0.4 | 3257 kg | 1561×1145×1209 mm | |
| SCB13-1600/10/0.48 | 1600kVA | 10 | 0.48 | 3257 kg | 1561×1145×1209 mm | |
| SCB13-1600/10/0.22 | 1600kVA | 10 | 0.22 | 3257 kg | 1561×1145×1209 mm | |
| SCB13-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 3257 kg | 1561×1145×1209 mm | |
| SCB13-2000/10/0.4 | 2000kVA | 10 | 0.4 | 3813 kg | 1647×1193×1268 mm | |
| SCB13-2000/6/0.4 | 2000kVA | 6 | 0.4 | 3813 kg | 1647×1193×1268 mm | |
| SCB13-2000/35/0.4 | 2000kVA | 35 | 0.4 | 3813 kg | 1647×1193×1268 mm | |
| SCB13-2000/10/0.48 | 2000kVA | 10 | 0.48 | 3813 kg | 1647×1193×1268 mm | |
| SCB13-2000/10/0.22 | 2000kVA | 10 | 0.22 | 3813 kg | 1647×1193×1268 mm | |
| SCB13-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 3813 kg | 1647×1193×1268 mm | |
| SCB13-2500/10/0.4 | 2500kVA | 10 | 0.4 | 4607 kg | 1734×1241×1327 mm | |
| SCB13-2500/6/0.4 | 2500kVA | 6 | 0.4 | 4607 kg | 1734×1241×1327 mm | |
| SCB13-2500/35/0.4 | 2500kVA | 35 | 0.4 | 4607 kg | 1734×1241×1327 mm | |
| SCB13-2500/10/0.48 | 2500kVA | 10 | 0.48 | 4607 kg | 1734×1241×1327 mm | |
| SCB13-2500/10/0.22 | 2500kVA | 10 | 0.22 | 4607 kg | 1734×1241×1327 mm | |
| SCB13-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 4607 kg | 1734×1241×1327 mm | |
| SCB13-3150/10/0.4 | 3150kVA | 10 | 0.4 | 5560.5 kg | 1821×1336×1415 mm | |
| SCB13-3150/6/0.4 | 3150kVA | 6 | 0.4 | 5560.5 kg | 1821×1336×1415 mm | |
| SCB13-3150/35/0.4 | 3150kVA | 35 | 0.4 | 5560.5 kg | 1821×1336×1415 mm | |
| SCB13-3150/10/0.48 | 3150kVA | 10 | 0.48 | 5560.5 kg | 1821×1336×1415 mm | |
| SCB13-3150/10/0.22 | 3150kVA | 10 | 0.22 | 5560.5 kg | 1821×1336×1415 mm | |
| SCB13-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 5560.5 kg | 1821×1336×1415 mm | |
| SCB13-4000/10/0.4 | 4000kVA | 10 | 0.4 | 6593 kg | 1908×1432×1504 mm | |
| SCB13-4000/6/0.4 | 4000kVA | 6 | 0.4 | 6593 kg | 1908×1432×1504 mm | |
| SCB13-4000/35/0.4 | 4000kVA | 35 | 0.4 | 6593 kg | 1908×1432×1504 mm | |
| SCB13-4000/10/0.48 | 4000kVA | 10 | 0.48 | 6593 kg | 1908×1432×1504 mm | |
| SCB13-4000/10/0.22 | 4000kVA | 10 | 0.22 | 6593 kg | 1908×1432×1504 mm | |
| SCB13-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 6593 kg | 1908×1432×1504 mm | |
| SCB13-5000/10/0.4 | 5000kVA | 10 | 0.4 | 7943.5 kg | 2081×1527×1592 mm | |
| SCB13-5000/6/0.4 | 5000kVA | 6 | 0.4 | 7943.5 kg | 2081×1527×1592 mm | |
| SCB13-5000/35/0.4 | 5000kVA | 35 | 0.4 | 7943.5 kg | 2081×1527×1592 mm | |
| SCB13-5000/10/0.48 | 5000kVA | 10 | 0.48 | 7943.5 kg | 2081×1527×1592 mm | |
| SCB13-5000/10/0.22 | 5000kVA | 10 | 0.22 | 7943.5 kg | 2081×1527×1592 mm | |
| SCB13-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 7943.5 kg | 2081×1527×1592 mm |
Selection Guide
Indoor use
Cast-resin, oil-free design is ideal for indoor commercial and industrial installations.
Efficiency
Level 3 efficiency - a solid balance of cost and energy performance.
Cooling
Natural air cooling (AN) standard; forced air (AF) available for higher capacity.
- Frequently Asked Questions
What efficiency level does SCB13 meet?
SCB13 meets Level 3 energy efficiency (GB 20052), reducing no-load losses versus conventional dry-type transformers.
Can SCB13 be installed indoors?
Yes, cast-resin construction is fire-safe and oil-free, ideal for indoor commercial and industrial installations.
What is the typical service life?
Over 30 years with Class F insulation and adequate ventilation.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(7)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
SCB13 及同损耗档(SCB13 / SG13 / SCL13 / SCR,Class 3)
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.