SCL13 Series - Cast Resin Dry-Type Transformers with Aluminum Winding (Level 3 Efficiency)

The SCL13 series features aluminum winding construction while maintaining Level 3 energy efficiency, offering cost-effective solutions for various applications. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, Class F insulation with 65 K temperature rise, IP00–IP31 enclosure (IP42–IP66 available on request). Suitable for indoor substations, data centers, commercial buildings, industrial plants, and solar/wind farms.

Model Number Breakdown

13Performance level designation, corresponds to Level 3 energy efficiency standard
SThree-phase power transformer
CCast resin insulation, dry-type transformer
LAluminum winding structure

Key Features

  • Level 3 energy efficiency rating
  • Cost-effective aluminum winding design
  • Lightweight construction
  • Reliable performance for general applications

Applications

  • General industrial use
  • Commercial buildings
  • Residential complexes
  • Light manufacturing

TECHNICAL DRAWING

Model: SCL13-250/10/0.48 | Type: Dry-type transformer | Capacity: 250 kVA

FRONT ELEVATION

LVLVLVHV1U1V1W2U2V2W2N180mm240mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDelta-Wye (IEEE Std)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Ventilation135mm

TOP VIEW

1U1V1WIron core180mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

AIR / ENCLOSUREHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity10–5000 kVA
HV Voltage (kV)10, 6, 35, 0.48
LV Voltage (kV)0.4, 0.48, 0.22, 0.208
Frequency (Hz)50, 60
Impedance (%)4, 4.5, 6, 7
CoolingAN/AF, AF
EfficiencyClass 3
StandardIEC 60076, IEEE C57 / ANSI C84.1
ConnectionDyn11 (IEC), Delta-Wye (IEEE Std)
Insulation classF (155°C)
Allowed temperature rise65
Noise level≤36 dB(A), ≤37 dB(A), ≤38 dB(A), ≤39 dB(A), ≤40 dB(A), ≤41 dB(A)…
Tap Changer±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap, ±8×1.25% OLTC
No-load loss61–4472 W
Load loss380–28760 W
Select 2-3 models to compare
CompareModelCapacity (kVA)HV Voltage (kV)LV Voltage (kV)WeightDimensions
SCL13-10/10/0.410kVA100.4217.5 kg582×471×550 mm
SCL13-10/6/0.410kVA60.4217.5 kg582×471×550 mm
SCL13-10/35/0.410kVA350.4217.5 kg582×471×550 mm
SCL13-10/10/0.4810kVA100.48217.5 kg582×471×550 mm
SCL13-10/10/0.2210kVA100.22217.5 kg582×471×550 mm
SCL13-10/0.48/0.20810kVA0.480.208217.5 kg582×471×550 mm
SCL13-15/10/0.415kVA100.4246.5 kg615×495×584 mm
SCL13-15/6/0.415kVA60.4246.5 kg615×495×584 mm
SCL13-15/35/0.415kVA350.4246.5 kg615×495×584 mm
SCL13-15/10/0.4815kVA100.48246.5 kg615×495×584 mm
SCL13-15/10/0.2215kVA100.22246.5 kg615×495×584 mm
SCL13-15/0.48/0.20815kVA0.480.208246.5 kg615×495×584 mm
SCL13-20/10/0.420kVA100.4275.5 kg648×518×618 mm
SCL13-20/6/0.420kVA60.4275.5 kg648×518×618 mm
SCL13-20/35/0.420kVA350.4275.5 kg648×518×618 mm
SCL13-20/10/0.4820kVA100.48275.5 kg648×518×618 mm
SCL13-20/10/0.2220kVA100.22275.5 kg648×518×618 mm
SCL13-20/0.48/0.20820kVA0.480.208275.5 kg648×518×618 mm
SCL13-25/10/0.425kVA100.4304.5 kg690×551×646 mm
SCL13-25/6/0.425kVA60.4304.5 kg690×551×646 mm
SCL13-25/35/0.425kVA350.4304.5 kg690×551×646 mm
SCL13-25/10/0.4825kVA100.48304.5 kg690×551×646 mm
SCL13-25/10/0.2225kVA100.22304.5 kg690×551×646 mm
SCL13-25/0.48/0.20825kVA0.480.208304.5 kg690×551×646 mm
SCL13-30/10/0.430kVA100.4333.5 kg732×584×673 mm
SCL13-30/6/0.430kVA60.4333.5 kg732×584×673 mm
SCL13-30/35/0.430kVA350.4333.5 kg732×584×673 mm
SCL13-30/10/0.4830kVA100.48333.5 kg732×584×673 mm
SCL13-30/10/0.2230kVA100.22333.5 kg732×584×673 mm
SCL13-30/0.48/0.20830kVA0.480.208333.5 kg732×584×673 mm
SCL13-40/10/0.440kVA100.4370 kg781×650×714 mm
SCL13-40/6/0.440kVA60.4370 kg781×650×714 mm
SCL13-40/35/0.440kVA350.4370 kg781×650×714 mm
SCL13-40/10/0.4840kVA100.48370 kg781×650×714 mm
SCL13-40/10/0.2240kVA100.22370 kg781×650×714 mm
SCL13-40/0.48/0.20840kVA0.480.208370 kg781×650×714 mm
SCL13-50/10/0.450kVA100.4406 kg831×716×756 mm
SCL13-50/6/0.450kVA60.4406 kg831×716×756 mm
SCL13-50/35/0.450kVA350.4406 kg831×716×756 mm
SCL13-50/10/0.4850kVA100.48406 kg831×716×756 mm
SCL13-50/10/0.2250kVA100.22406 kg831×716×756 mm
SCL13-50/0.48/0.20850kVA0.480.208406 kg831×716×756 mm
SCL13-63/10/0.463kVA100.4449.5 kg848×730×780 mm
SCL13-63/6/0.463kVA60.4449.5 kg848×730×780 mm
SCL13-63/35/0.463kVA350.4449.5 kg848×730×780 mm
SCL13-63/10/0.4863kVA100.48449.5 kg848×730×780 mm
SCL13-63/10/0.2263kVA100.22449.5 kg848×730×780 mm
SCL13-63/0.48/0.20863kVA0.480.208449.5 kg848×730×780 mm
SCL13-80/10/0.480kVA100.4507 kg873×754×811 mm
SCL13-80/6/0.480kVA60.4507 kg873×754×811 mm
SCL13-80/35/0.480kVA350.4507 kg873×754×811 mm
SCL13-80/10/0.4880kVA100.48507 kg873×754×811 mm
SCL13-80/10/0.2280kVA100.22507 kg873×754×811 mm
SCL13-80/0.48/0.20880kVA0.480.208507 kg873×754×811 mm
SCL13-100/10/0.4100kVA100.4580 kg915×754×859 mm
SCL13-100/6/0.4100kVA60.4580 kg915×754×859 mm
SCL13-100/35/0.4100kVA350.4580 kg915×754×859 mm
SCL13-100/10/0.48100kVA100.48580 kg915×754×859 mm
SCL13-100/10/0.22100kVA100.22580 kg915×754×859 mm
SCL13-100/0.48/0.208100kVA0.480.208580 kg915×754×859 mm
SCL13-125/10/0.4125kVA100.4652 kg956×773×893 mm
SCL13-125/6/0.4125kVA60.4652 kg956×773×893 mm
SCL13-125/35/0.4125kVA350.4652 kg956×773×893 mm
SCL13-125/10/0.48125kVA100.48652 kg956×773×893 mm
SCL13-125/10/0.22125kVA100.22652 kg956×773×893 mm
SCL13-125/0.48/0.208125kVA0.480.208652 kg956×773×893 mm
SCL13-160/10/0.4160kVA100.4761 kg998×801×927 mm
SCL13-160/6/0.4160kVA60.4761 kg998×801×927 mm
SCL13-160/35/0.4160kVA350.4761 kg998×801×927 mm
SCL13-160/10/0.48160kVA100.48761 kg998×801×927 mm
SCL13-160/10/0.22160kVA100.22761 kg998×801×927 mm
SCL13-160/0.48/0.208160kVA0.480.208761 kg998×801×927 mm
SCL13-200/10/0.4200kVA100.4870 kg1039×829×962 mm
SCL13-200/6/0.4200kVA60.4870 kg1039×829×962 mm
SCL13-200/35/0.4200kVA350.4870 kg1039×829×962 mm
SCL13-200/10/0.48200kVA100.48870 kg1039×829×962 mm
SCL13-200/10/0.22200kVA100.22870 kg1039×829×962 mm
SCL13-200/0.48/0.208200kVA0.480.208870 kg1039×829×962 mm
SCL13-250/10/0.4250kVA100.4979 kg1081×848×996 mm
SCL13-250/6/0.4250kVA60.4979 kg1081×848×996 mm
SCL13-250/35/0.4250kVA350.4979 kg1081×848×996 mm
SCL13-250/10/0.48250kVA100.48979 kg1081×848×996 mm
SCL13-250/10/0.22250kVA100.22979 kg1081×848×996 mm
SCL13-250/0.48/0.208250kVA0.480.208979 kg1081×848×996 mm
SCL13-315/10/0.4315kVA100.41124 kg1122×895×1030 mm
SCL13-315/6/0.4315kVA60.41124 kg1122×895×1030 mm
SCL13-315/35/0.4315kVA350.41124 kg1122×895×1030 mm
SCL13-315/10/0.48315kVA100.481124 kg1122×895×1030 mm
SCL13-315/10/0.22315kVA100.221124 kg1122×895×1030 mm
SCL13-315/0.48/0.208315kVA0.480.2081124 kg1122×895×1030 mm
SCL13-400/10/0.4400kVA100.41380 kg1090×900×1060 mm
SCL13-400/6/0.4400kVA60.41380 kg1090×900×1060 mm
SCL13-400/35/0.4400kVA350.41380 kg1090×900×1060 mm
SCL13-400/10/0.48400kVA100.481380 kg1090×900×1060 mm
SCL13-400/10/0.22400kVA100.221380 kg1090×900×1060 mm
SCL13-400/0.48/0.208400kVA0.480.2081380 kg1090×900×1060 mm
SCL13-500/10/0.4500kVA100.41461 kg1090×930×1100 mm
SCL13-500/6/0.4500kVA60.41461 kg1090×930×1100 mm
SCL13-500/35/0.4500kVA350.41461 kg1090×930×1100 mm
SCL13-500/10/0.48500kVA100.481461 kg1090×930×1100 mm
SCL13-500/10/0.22500kVA100.221461 kg1090×930×1100 mm
SCL13-500/0.48/0.208500kVA0.480.2081461 kg1090×930×1100 mm
SCL13-630/10/0.4630kVA100.41619 kg1250×1050×1170 mm
SCL13-630/6/0.4630kVA60.41619 kg1250×1050×1170 mm
SCL13-630/35/0.4630kVA350.41619 kg1250×1050×1170 mm
SCL13-630/10/0.48630kVA100.481619 kg1250×1050×1170 mm
SCL13-630/10/0.22630kVA100.221619 kg1250×1050×1170 mm
SCL13-630/0.48/0.208630kVA0.480.2081619 kg1250×1050×1170 mm
SCL13-800/10/0.4800kVA100.41931 kg1330×1050×1200 mm
SCL13-800/6/0.4800kVA60.41931 kg1330×1050×1200 mm
SCL13-800/35/0.4800kVA350.41931 kg1330×1050×1200 mm
SCL13-800/10/0.48800kVA100.481931 kg1330×1050×1200 mm
SCL13-800/10/0.22800kVA100.221931 kg1330×1050×1200 mm
SCL13-800/0.48/0.208800kVA0.480.2081931 kg1330×1050×1200 mm
SCL13-1000/10/0.41000kVA100.42204 kg1380×1050×1270 mm
SCL13-1000/6/0.41000kVA60.42204 kg1380×1050×1270 mm
SCL13-1000/35/0.41000kVA350.42204 kg1380×1050×1270 mm
SCL13-1000/10/0.481000kVA100.482204 kg1380×1050×1270 mm
SCL13-1000/10/0.221000kVA100.222204 kg1380×1050×1270 mm
SCL13-1000/0.48/0.2081000kVA0.480.2082204 kg1380×1050×1270 mm
SCL13-1250/10/0.41250kVA100.42588 kg1410×1070×1370 mm
SCL13-1250/6/0.41250kVA60.42588 kg1410×1070×1370 mm
SCL13-1250/35/0.41250kVA350.42588 kg1410×1070×1370 mm
SCL13-1250/10/0.481250kVA100.482588 kg1410×1070×1370 mm
SCL13-1250/10/0.221250kVA100.222588 kg1410×1070×1370 mm
SCL13-1250/0.48/0.2081250kVA0.480.2082588 kg1410×1070×1370 mm
SCL13-1600/10/0.41600kVA100.42972 kg1496×1131×1408 mm
SCL13-1600/6/0.41600kVA60.42972 kg1496×1131×1408 mm
SCL13-1600/35/0.41600kVA350.42972 kg1496×1131×1408 mm
SCL13-1600/10/0.481600kVA100.482972 kg1496×1131×1408 mm
SCL13-1600/10/0.221600kVA100.222972 kg1496×1131×1408 mm
SCL13-1600/0.48/0.2081600kVA0.480.2082972 kg1496×1131×1408 mm
SCL13-2000/10/0.42000kVA100.43480 kg1580×1178×1477 mm
SCL13-2000/6/0.42000kVA60.43480 kg1580×1178×1477 mm
SCL13-2000/35/0.42000kVA350.43480 kg1580×1178×1477 mm
SCL13-2000/10/0.482000kVA100.483480 kg1580×1178×1477 mm
SCL13-2000/10/0.222000kVA100.223480 kg1580×1178×1477 mm
SCL13-2000/0.48/0.2082000kVA0.480.2083480 kg1580×1178×1477 mm
SCL13-2500/10/0.42500kVA100.44205 kg1663×1225×1546 mm
SCL13-2500/6/0.42500kVA60.44205 kg1663×1225×1546 mm
SCL13-2500/35/0.42500kVA350.44205 kg1663×1225×1546 mm
SCL13-2500/10/0.482500kVA100.484205 kg1663×1225×1546 mm
SCL13-2500/10/0.222500kVA100.224205 kg1663×1225×1546 mm
SCL13-2500/0.48/0.2082500kVA0.480.2084205 kg1663×1225×1546 mm
SCL13-3150/10/0.43150kVA100.45074.5 kg1746×1319×1649 mm
SCL13-3150/6/0.43150kVA60.45074.5 kg1746×1319×1649 mm
SCL13-3150/35/0.43150kVA350.45074.5 kg1746×1319×1649 mm
SCL13-3150/10/0.483150kVA100.485074.5 kg1746×1319×1649 mm
SCL13-3150/10/0.223150kVA100.225074.5 kg1746×1319×1649 mm
SCL13-3150/0.48/0.2083150kVA0.480.2085074.5 kg1746×1319×1649 mm
SCL13-4000/10/0.44000kVA100.46017 kg1829×1414×1752 mm
SCL13-4000/6/0.44000kVA60.46017 kg1829×1414×1752 mm
SCL13-4000/35/0.44000kVA350.46017 kg1829×1414×1752 mm
SCL13-4000/10/0.484000kVA100.486017 kg1829×1414×1752 mm
SCL13-4000/10/0.224000kVA100.226017 kg1829×1414×1752 mm
SCL13-4000/0.48/0.2084000kVA0.480.2086017 kg1829×1414×1752 mm
SCL13-5000/10/0.45000kVA100.47249 kg1995×1508×1855 mm
SCL13-5000/6/0.45000kVA60.47249 kg1995×1508×1855 mm
SCL13-5000/35/0.45000kVA350.47249 kg1995×1508×1855 mm
SCL13-5000/10/0.485000kVA100.487249 kg1995×1508×1855 mm
SCL13-5000/10/0.225000kVA100.227249 kg1995×1508×1855 mm
SCL13-5000/0.48/0.2085000kVA0.480.2087249 kg1995×1508×1855 mm

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
2 · Your price
EXW (FOB Qingdao)
$7,396
Range $6,804 ~ $7,9878%)
Price Breakdown
Base price (interpolation)$7,396
× Product factor×1.0000
× Country factor×1.0000
× Copper-linked factor×1.0000
+ Options / accessories$0
Shipping quoted separately per destination port.

Aluminum winding — no copper linkage

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.