SCL13 Series - Cast Resin Dry-Type Transformers with Aluminum Winding (Level 3 Efficiency)
The SCL13 series features aluminum winding construction while maintaining Level 3 energy efficiency, offering cost-effective solutions for various applications. Rated 10–5000 kVA, 0.48–35 kV primary and 0.208–0.48 kV secondary, Class F insulation with 65 K temperature rise, IP00–IP31 enclosure (IP42–IP66 available on request). Suitable for indoor substations, data centers, commercial buildings, industrial plants, and solar/wind farms.
Model Number Breakdown
Key Features
- Level 3 energy efficiency rating
- Cost-effective aluminum winding design
- Lightweight construction
- Reliable performance for general applications
Applications
- General industrial use
- Commercial buildings
- Residential complexes
- Light manufacturing
TECHNICAL DRAWING
Model: SCL13-250/10/0.48 | Type: Dry-type transformer | Capacity: 250 kVA
FRONT ELEVATION
ELECTRICAL SCHEMATIC
EFFICIENCY vs LOAD
SIDE VIEW
TOP VIEW
TERMINAL BLOCK
CORE & WINDING
LEGEND:
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 10–5000 kVA |
| HV Voltage (kV) | 10, 6, 35, 0.48 |
| LV Voltage (kV) | 0.4, 0.48, 0.22, 0.208 |
| Frequency (Hz) | 50, 60 |
| Impedance (%) | 4, 4.5, 6, 7 |
| Cooling | AN/AF, AF |
| Efficiency | Class 3 |
| Standard | IEC 60076, IEEE C57 / ANSI C84.1 |
| Connection | Dyn11 (IEC), Delta-Wye (IEEE Std) |
| Insulation class | F (155°C) |
| Allowed temperature rise | 65 |
| Noise level | ≤36 dB(A), ≤37 dB(A), ≤38 dB(A), ≤39 dB(A), ≤40 dB(A), ≤41 dB(A)… |
| Tap Changer | ±2×2.5% Multi-tap, ±5% Single-tap, ±5×2.5% Multi-tap |
| No-load loss | 61–4472 W |
| Load loss | 380–28760 W |
| Compare | Model | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Weight | Dimensions |
|---|---|---|---|---|---|---|
| SCL13-10/10/0.4 | 10kVA | 10 | 0.4 | 217.5 kg | 582×471×550 mm | |
| SCL13-10/6/0.4 | 10kVA | 6 | 0.4 | 217.5 kg | 582×471×550 mm | |
| SCL13-10/35/0.4 | 10kVA | 35 | 0.4 | 217.5 kg | 582×471×550 mm | |
| SCL13-10/10/0.48 | 10kVA | 10 | 0.48 | 217.5 kg | 582×471×550 mm | |
| SCL13-10/10/0.22 | 10kVA | 10 | 0.22 | 217.5 kg | 582×471×550 mm | |
| SCL13-10/0.48/0.208 | 10kVA | 0.48 | 0.208 | 217.5 kg | 582×471×550 mm | |
| SCL13-15/10/0.4 | 15kVA | 10 | 0.4 | 246.5 kg | 615×495×584 mm | |
| SCL13-15/6/0.4 | 15kVA | 6 | 0.4 | 246.5 kg | 615×495×584 mm | |
| SCL13-15/35/0.4 | 15kVA | 35 | 0.4 | 246.5 kg | 615×495×584 mm | |
| SCL13-15/10/0.48 | 15kVA | 10 | 0.48 | 246.5 kg | 615×495×584 mm | |
| SCL13-15/10/0.22 | 15kVA | 10 | 0.22 | 246.5 kg | 615×495×584 mm | |
| SCL13-15/0.48/0.208 | 15kVA | 0.48 | 0.208 | 246.5 kg | 615×495×584 mm | |
| SCL13-20/10/0.4 | 20kVA | 10 | 0.4 | 275.5 kg | 648×518×618 mm | |
| SCL13-20/6/0.4 | 20kVA | 6 | 0.4 | 275.5 kg | 648×518×618 mm | |
| SCL13-20/35/0.4 | 20kVA | 35 | 0.4 | 275.5 kg | 648×518×618 mm | |
| SCL13-20/10/0.48 | 20kVA | 10 | 0.48 | 275.5 kg | 648×518×618 mm | |
| SCL13-20/10/0.22 | 20kVA | 10 | 0.22 | 275.5 kg | 648×518×618 mm | |
| SCL13-20/0.48/0.208 | 20kVA | 0.48 | 0.208 | 275.5 kg | 648×518×618 mm | |
| SCL13-25/10/0.4 | 25kVA | 10 | 0.4 | 304.5 kg | 690×551×646 mm | |
| SCL13-25/6/0.4 | 25kVA | 6 | 0.4 | 304.5 kg | 690×551×646 mm | |
| SCL13-25/35/0.4 | 25kVA | 35 | 0.4 | 304.5 kg | 690×551×646 mm | |
| SCL13-25/10/0.48 | 25kVA | 10 | 0.48 | 304.5 kg | 690×551×646 mm | |
| SCL13-25/10/0.22 | 25kVA | 10 | 0.22 | 304.5 kg | 690×551×646 mm | |
| SCL13-25/0.48/0.208 | 25kVA | 0.48 | 0.208 | 304.5 kg | 690×551×646 mm | |
| SCL13-30/10/0.4 | 30kVA | 10 | 0.4 | 333.5 kg | 732×584×673 mm | |
| SCL13-30/6/0.4 | 30kVA | 6 | 0.4 | 333.5 kg | 732×584×673 mm | |
| SCL13-30/35/0.4 | 30kVA | 35 | 0.4 | 333.5 kg | 732×584×673 mm | |
| SCL13-30/10/0.48 | 30kVA | 10 | 0.48 | 333.5 kg | 732×584×673 mm | |
| SCL13-30/10/0.22 | 30kVA | 10 | 0.22 | 333.5 kg | 732×584×673 mm | |
| SCL13-30/0.48/0.208 | 30kVA | 0.48 | 0.208 | 333.5 kg | 732×584×673 mm | |
| SCL13-40/10/0.4 | 40kVA | 10 | 0.4 | 370 kg | 781×650×714 mm | |
| SCL13-40/6/0.4 | 40kVA | 6 | 0.4 | 370 kg | 781×650×714 mm | |
| SCL13-40/35/0.4 | 40kVA | 35 | 0.4 | 370 kg | 781×650×714 mm | |
| SCL13-40/10/0.48 | 40kVA | 10 | 0.48 | 370 kg | 781×650×714 mm | |
| SCL13-40/10/0.22 | 40kVA | 10 | 0.22 | 370 kg | 781×650×714 mm | |
| SCL13-40/0.48/0.208 | 40kVA | 0.48 | 0.208 | 370 kg | 781×650×714 mm | |
| SCL13-50/10/0.4 | 50kVA | 10 | 0.4 | 406 kg | 831×716×756 mm | |
| SCL13-50/6/0.4 | 50kVA | 6 | 0.4 | 406 kg | 831×716×756 mm | |
| SCL13-50/35/0.4 | 50kVA | 35 | 0.4 | 406 kg | 831×716×756 mm | |
| SCL13-50/10/0.48 | 50kVA | 10 | 0.48 | 406 kg | 831×716×756 mm | |
| SCL13-50/10/0.22 | 50kVA | 10 | 0.22 | 406 kg | 831×716×756 mm | |
| SCL13-50/0.48/0.208 | 50kVA | 0.48 | 0.208 | 406 kg | 831×716×756 mm | |
| SCL13-63/10/0.4 | 63kVA | 10 | 0.4 | 449.5 kg | 848×730×780 mm | |
| SCL13-63/6/0.4 | 63kVA | 6 | 0.4 | 449.5 kg | 848×730×780 mm | |
| SCL13-63/35/0.4 | 63kVA | 35 | 0.4 | 449.5 kg | 848×730×780 mm | |
| SCL13-63/10/0.48 | 63kVA | 10 | 0.48 | 449.5 kg | 848×730×780 mm | |
| SCL13-63/10/0.22 | 63kVA | 10 | 0.22 | 449.5 kg | 848×730×780 mm | |
| SCL13-63/0.48/0.208 | 63kVA | 0.48 | 0.208 | 449.5 kg | 848×730×780 mm | |
| SCL13-80/10/0.4 | 80kVA | 10 | 0.4 | 507 kg | 873×754×811 mm | |
| SCL13-80/6/0.4 | 80kVA | 6 | 0.4 | 507 kg | 873×754×811 mm | |
| SCL13-80/35/0.4 | 80kVA | 35 | 0.4 | 507 kg | 873×754×811 mm | |
| SCL13-80/10/0.48 | 80kVA | 10 | 0.48 | 507 kg | 873×754×811 mm | |
| SCL13-80/10/0.22 | 80kVA | 10 | 0.22 | 507 kg | 873×754×811 mm | |
| SCL13-80/0.48/0.208 | 80kVA | 0.48 | 0.208 | 507 kg | 873×754×811 mm | |
| SCL13-100/10/0.4 | 100kVA | 10 | 0.4 | 580 kg | 915×754×859 mm | |
| SCL13-100/6/0.4 | 100kVA | 6 | 0.4 | 580 kg | 915×754×859 mm | |
| SCL13-100/35/0.4 | 100kVA | 35 | 0.4 | 580 kg | 915×754×859 mm | |
| SCL13-100/10/0.48 | 100kVA | 10 | 0.48 | 580 kg | 915×754×859 mm | |
| SCL13-100/10/0.22 | 100kVA | 10 | 0.22 | 580 kg | 915×754×859 mm | |
| SCL13-100/0.48/0.208 | 100kVA | 0.48 | 0.208 | 580 kg | 915×754×859 mm | |
| SCL13-125/10/0.4 | 125kVA | 10 | 0.4 | 652 kg | 956×773×893 mm | |
| SCL13-125/6/0.4 | 125kVA | 6 | 0.4 | 652 kg | 956×773×893 mm | |
| SCL13-125/35/0.4 | 125kVA | 35 | 0.4 | 652 kg | 956×773×893 mm | |
| SCL13-125/10/0.48 | 125kVA | 10 | 0.48 | 652 kg | 956×773×893 mm | |
| SCL13-125/10/0.22 | 125kVA | 10 | 0.22 | 652 kg | 956×773×893 mm | |
| SCL13-125/0.48/0.208 | 125kVA | 0.48 | 0.208 | 652 kg | 956×773×893 mm | |
| SCL13-160/10/0.4 | 160kVA | 10 | 0.4 | 761 kg | 998×801×927 mm | |
| SCL13-160/6/0.4 | 160kVA | 6 | 0.4 | 761 kg | 998×801×927 mm | |
| SCL13-160/35/0.4 | 160kVA | 35 | 0.4 | 761 kg | 998×801×927 mm | |
| SCL13-160/10/0.48 | 160kVA | 10 | 0.48 | 761 kg | 998×801×927 mm | |
| SCL13-160/10/0.22 | 160kVA | 10 | 0.22 | 761 kg | 998×801×927 mm | |
| SCL13-160/0.48/0.208 | 160kVA | 0.48 | 0.208 | 761 kg | 998×801×927 mm | |
| SCL13-200/10/0.4 | 200kVA | 10 | 0.4 | 870 kg | 1039×829×962 mm | |
| SCL13-200/6/0.4 | 200kVA | 6 | 0.4 | 870 kg | 1039×829×962 mm | |
| SCL13-200/35/0.4 | 200kVA | 35 | 0.4 | 870 kg | 1039×829×962 mm | |
| SCL13-200/10/0.48 | 200kVA | 10 | 0.48 | 870 kg | 1039×829×962 mm | |
| SCL13-200/10/0.22 | 200kVA | 10 | 0.22 | 870 kg | 1039×829×962 mm | |
| SCL13-200/0.48/0.208 | 200kVA | 0.48 | 0.208 | 870 kg | 1039×829×962 mm | |
| SCL13-250/10/0.4 | 250kVA | 10 | 0.4 | 979 kg | 1081×848×996 mm | |
| SCL13-250/6/0.4 | 250kVA | 6 | 0.4 | 979 kg | 1081×848×996 mm | |
| SCL13-250/35/0.4 | 250kVA | 35 | 0.4 | 979 kg | 1081×848×996 mm | |
| SCL13-250/10/0.48 | 250kVA | 10 | 0.48 | 979 kg | 1081×848×996 mm | |
| SCL13-250/10/0.22 | 250kVA | 10 | 0.22 | 979 kg | 1081×848×996 mm | |
| SCL13-250/0.48/0.208 | 250kVA | 0.48 | 0.208 | 979 kg | 1081×848×996 mm | |
| SCL13-315/10/0.4 | 315kVA | 10 | 0.4 | 1124 kg | 1122×895×1030 mm | |
| SCL13-315/6/0.4 | 315kVA | 6 | 0.4 | 1124 kg | 1122×895×1030 mm | |
| SCL13-315/35/0.4 | 315kVA | 35 | 0.4 | 1124 kg | 1122×895×1030 mm | |
| SCL13-315/10/0.48 | 315kVA | 10 | 0.48 | 1124 kg | 1122×895×1030 mm | |
| SCL13-315/10/0.22 | 315kVA | 10 | 0.22 | 1124 kg | 1122×895×1030 mm | |
| SCL13-315/0.48/0.208 | 315kVA | 0.48 | 0.208 | 1124 kg | 1122×895×1030 mm | |
| SCL13-400/10/0.4 | 400kVA | 10 | 0.4 | 1380 kg | 1090×900×1060 mm | |
| SCL13-400/6/0.4 | 400kVA | 6 | 0.4 | 1380 kg | 1090×900×1060 mm | |
| SCL13-400/35/0.4 | 400kVA | 35 | 0.4 | 1380 kg | 1090×900×1060 mm | |
| SCL13-400/10/0.48 | 400kVA | 10 | 0.48 | 1380 kg | 1090×900×1060 mm | |
| SCL13-400/10/0.22 | 400kVA | 10 | 0.22 | 1380 kg | 1090×900×1060 mm | |
| SCL13-400/0.48/0.208 | 400kVA | 0.48 | 0.208 | 1380 kg | 1090×900×1060 mm | |
| SCL13-500/10/0.4 | 500kVA | 10 | 0.4 | 1461 kg | 1090×930×1100 mm | |
| SCL13-500/6/0.4 | 500kVA | 6 | 0.4 | 1461 kg | 1090×930×1100 mm | |
| SCL13-500/35/0.4 | 500kVA | 35 | 0.4 | 1461 kg | 1090×930×1100 mm | |
| SCL13-500/10/0.48 | 500kVA | 10 | 0.48 | 1461 kg | 1090×930×1100 mm | |
| SCL13-500/10/0.22 | 500kVA | 10 | 0.22 | 1461 kg | 1090×930×1100 mm | |
| SCL13-500/0.48/0.208 | 500kVA | 0.48 | 0.208 | 1461 kg | 1090×930×1100 mm | |
| SCL13-630/10/0.4 | 630kVA | 10 | 0.4 | 1619 kg | 1250×1050×1170 mm | |
| SCL13-630/6/0.4 | 630kVA | 6 | 0.4 | 1619 kg | 1250×1050×1170 mm | |
| SCL13-630/35/0.4 | 630kVA | 35 | 0.4 | 1619 kg | 1250×1050×1170 mm | |
| SCL13-630/10/0.48 | 630kVA | 10 | 0.48 | 1619 kg | 1250×1050×1170 mm | |
| SCL13-630/10/0.22 | 630kVA | 10 | 0.22 | 1619 kg | 1250×1050×1170 mm | |
| SCL13-630/0.48/0.208 | 630kVA | 0.48 | 0.208 | 1619 kg | 1250×1050×1170 mm | |
| SCL13-800/10/0.4 | 800kVA | 10 | 0.4 | 1931 kg | 1330×1050×1200 mm | |
| SCL13-800/6/0.4 | 800kVA | 6 | 0.4 | 1931 kg | 1330×1050×1200 mm | |
| SCL13-800/35/0.4 | 800kVA | 35 | 0.4 | 1931 kg | 1330×1050×1200 mm | |
| SCL13-800/10/0.48 | 800kVA | 10 | 0.48 | 1931 kg | 1330×1050×1200 mm | |
| SCL13-800/10/0.22 | 800kVA | 10 | 0.22 | 1931 kg | 1330×1050×1200 mm | |
| SCL13-800/0.48/0.208 | 800kVA | 0.48 | 0.208 | 1931 kg | 1330×1050×1200 mm | |
| SCL13-1000/10/0.4 | 1000kVA | 10 | 0.4 | 2204 kg | 1380×1050×1270 mm | |
| SCL13-1000/6/0.4 | 1000kVA | 6 | 0.4 | 2204 kg | 1380×1050×1270 mm | |
| SCL13-1000/35/0.4 | 1000kVA | 35 | 0.4 | 2204 kg | 1380×1050×1270 mm | |
| SCL13-1000/10/0.48 | 1000kVA | 10 | 0.48 | 2204 kg | 1380×1050×1270 mm | |
| SCL13-1000/10/0.22 | 1000kVA | 10 | 0.22 | 2204 kg | 1380×1050×1270 mm | |
| SCL13-1000/0.48/0.208 | 1000kVA | 0.48 | 0.208 | 2204 kg | 1380×1050×1270 mm | |
| SCL13-1250/10/0.4 | 1250kVA | 10 | 0.4 | 2588 kg | 1410×1070×1370 mm | |
| SCL13-1250/6/0.4 | 1250kVA | 6 | 0.4 | 2588 kg | 1410×1070×1370 mm | |
| SCL13-1250/35/0.4 | 1250kVA | 35 | 0.4 | 2588 kg | 1410×1070×1370 mm | |
| SCL13-1250/10/0.48 | 1250kVA | 10 | 0.48 | 2588 kg | 1410×1070×1370 mm | |
| SCL13-1250/10/0.22 | 1250kVA | 10 | 0.22 | 2588 kg | 1410×1070×1370 mm | |
| SCL13-1250/0.48/0.208 | 1250kVA | 0.48 | 0.208 | 2588 kg | 1410×1070×1370 mm | |
| SCL13-1600/10/0.4 | 1600kVA | 10 | 0.4 | 2972 kg | 1496×1131×1408 mm | |
| SCL13-1600/6/0.4 | 1600kVA | 6 | 0.4 | 2972 kg | 1496×1131×1408 mm | |
| SCL13-1600/35/0.4 | 1600kVA | 35 | 0.4 | 2972 kg | 1496×1131×1408 mm | |
| SCL13-1600/10/0.48 | 1600kVA | 10 | 0.48 | 2972 kg | 1496×1131×1408 mm | |
| SCL13-1600/10/0.22 | 1600kVA | 10 | 0.22 | 2972 kg | 1496×1131×1408 mm | |
| SCL13-1600/0.48/0.208 | 1600kVA | 0.48 | 0.208 | 2972 kg | 1496×1131×1408 mm | |
| SCL13-2000/10/0.4 | 2000kVA | 10 | 0.4 | 3480 kg | 1580×1178×1477 mm | |
| SCL13-2000/6/0.4 | 2000kVA | 6 | 0.4 | 3480 kg | 1580×1178×1477 mm | |
| SCL13-2000/35/0.4 | 2000kVA | 35 | 0.4 | 3480 kg | 1580×1178×1477 mm | |
| SCL13-2000/10/0.48 | 2000kVA | 10 | 0.48 | 3480 kg | 1580×1178×1477 mm | |
| SCL13-2000/10/0.22 | 2000kVA | 10 | 0.22 | 3480 kg | 1580×1178×1477 mm | |
| SCL13-2000/0.48/0.208 | 2000kVA | 0.48 | 0.208 | 3480 kg | 1580×1178×1477 mm | |
| SCL13-2500/10/0.4 | 2500kVA | 10 | 0.4 | 4205 kg | 1663×1225×1546 mm | |
| SCL13-2500/6/0.4 | 2500kVA | 6 | 0.4 | 4205 kg | 1663×1225×1546 mm | |
| SCL13-2500/35/0.4 | 2500kVA | 35 | 0.4 | 4205 kg | 1663×1225×1546 mm | |
| SCL13-2500/10/0.48 | 2500kVA | 10 | 0.48 | 4205 kg | 1663×1225×1546 mm | |
| SCL13-2500/10/0.22 | 2500kVA | 10 | 0.22 | 4205 kg | 1663×1225×1546 mm | |
| SCL13-2500/0.48/0.208 | 2500kVA | 0.48 | 0.208 | 4205 kg | 1663×1225×1546 mm | |
| SCL13-3150/10/0.4 | 3150kVA | 10 | 0.4 | 5074.5 kg | 1746×1319×1649 mm | |
| SCL13-3150/6/0.4 | 3150kVA | 6 | 0.4 | 5074.5 kg | 1746×1319×1649 mm | |
| SCL13-3150/35/0.4 | 3150kVA | 35 | 0.4 | 5074.5 kg | 1746×1319×1649 mm | |
| SCL13-3150/10/0.48 | 3150kVA | 10 | 0.48 | 5074.5 kg | 1746×1319×1649 mm | |
| SCL13-3150/10/0.22 | 3150kVA | 10 | 0.22 | 5074.5 kg | 1746×1319×1649 mm | |
| SCL13-3150/0.48/0.208 | 3150kVA | 0.48 | 0.208 | 5074.5 kg | 1746×1319×1649 mm | |
| SCL13-4000/10/0.4 | 4000kVA | 10 | 0.4 | 6017 kg | 1829×1414×1752 mm | |
| SCL13-4000/6/0.4 | 4000kVA | 6 | 0.4 | 6017 kg | 1829×1414×1752 mm | |
| SCL13-4000/35/0.4 | 4000kVA | 35 | 0.4 | 6017 kg | 1829×1414×1752 mm | |
| SCL13-4000/10/0.48 | 4000kVA | 10 | 0.48 | 6017 kg | 1829×1414×1752 mm | |
| SCL13-4000/10/0.22 | 4000kVA | 10 | 0.22 | 6017 kg | 1829×1414×1752 mm | |
| SCL13-4000/0.48/0.208 | 4000kVA | 0.48 | 0.208 | 6017 kg | 1829×1414×1752 mm | |
| SCL13-5000/10/0.4 | 5000kVA | 10 | 0.4 | 7249 kg | 1995×1508×1855 mm | |
| SCL13-5000/6/0.4 | 5000kVA | 6 | 0.4 | 7249 kg | 1995×1508×1855 mm | |
| SCL13-5000/35/0.4 | 5000kVA | 35 | 0.4 | 7249 kg | 1995×1508×1855 mm | |
| SCL13-5000/10/0.48 | 5000kVA | 10 | 0.48 | 7249 kg | 1995×1508×1855 mm | |
| SCL13-5000/10/0.22 | 5000kVA | 10 | 0.22 | 7249 kg | 1995×1508×1855 mm | |
| SCL13-5000/0.48/0.208 | 5000kVA | 0.48 | 0.208 | 7249 kg | 1995×1508×1855 mm |
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(7)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
SCB13 及同损耗档(SCB13 / SG13 / SCL13 / SCR,Class 3)
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.