QDTB® Transformer

Product Search

Find the right transformer for your needs

GCK Series Low Voltage Switchgear

12 Models available

GCK Low Voltage Switchgear

Images are for illustration purposes only

GCK Series - Withdrawable Low-Voltage Switchgear

The GCK series represents withdrawable low-voltage switchgear for power distribution and motor control, offering flexible configuration and easy maintenance. Rated 380 V, IP30 enclosure (IP54/IP66 outdoor options available on request). Suitable for indoor substations, motor control centers (MCC), industrial plants, and building power distribution.

Model Number Breakdown

GSwitchgear
CWithdrawable type
KControl application

Applications

1

Power distribution

2

Motor control centers

3

Industrial power systems

4

Commercial buildings

Key Features

  • Withdrawable drawer design
  • Flexible configuration
  • Easy maintenance
  • High reliability

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Rated Voltage0.38
Busbar Rated Current630–4000 A
Short-time Withstand Current30–80 kA
Breaking Capacity30–80 kA
Protection LevelIP40
Enclosure MaterialCold-rolled steel
StandardGB7251, IEC 61439
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)LV Voltage (kV)Current (A)Frequency (Hz)InsulationStandardWeightDimensions
GCK/630GCK0.380.3863050IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/630(60Hz)GCK0.380.3863060IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/1000GCK0.380.38100050IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/1000(60Hz)GCK0.380.38100060IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/1600GCK0.380.38160050IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/1600(60Hz)GCK0.380.38160060IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/2000GCK0.380.38200050IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/2000(60Hz)GCK0.380.38200060IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/3150GCK0.380.38315050IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/3150(60Hz)GCK0.380.38315060IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/4000GCK0.380.38400050IP30GB7251, IEC 61439300 kg600×800×2200 mm
GCK/4000(60Hz)GCK0.380.38400060IP30GB7251, IEC 61439300 kg600×800×2200 mm

Product Drawing

Low Voltage Switchgear - GCK/630

APPEARANCE — DRAWOUT CABINET
BUSWAYDRAWER 1DRAWER 2DRAWER 3DRAWER 4DRAWER 5GCK/630
MAIN CIRCUIT — BUSBAR & FEEDERS
LV SWITCHGEAR — MAIN CIRCUITINCOMINGF1F2F3F4GCK/630
DRAWER CONFIGURATION
DRAWER CONFIGURATIONwithdrawable drawer unitsIncoming1250AFeeder250AFeeder250AFeeder250AGCK/630

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Type

Withdrawable drawer design for quick replacement without full de-energizing.

2

Standard

IEC 61439 low-voltage assemblies.

3

Application

Motor control and industrial distribution.

- Frequently Asked Questions

What is GCK?

A withdrawable low-voltage switchgear with modular drawer units for motor control and distribution.

Withdrawable vs fixed?

Withdrawable drawers allow fast replacement without de-energizing the whole panel.

What standard does GCK follow?

IEC 61439 low-voltage switchgear assemblies.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: LV assembly — IEC 61439-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators