QDTB® Transformer

Product Search

Find the right transformer for your needs

GGD Series Low Voltage Switchgear

12 Models available

GGD Low Voltage Switchgear

Images are for illustration purposes only

GGD Series - Fixed Low-Voltage Distribution Switchgear

The GGD series represents fixed low-voltage distribution switchgear for general power distribution applications, offering cost-effective and reliable solutions. Rated 380 V, IP30 enclosure (IP54/IP66 outdoor options available on request). Suitable for indoor substations, motor control centers (MCC), industrial plants, and building power distribution.

Model Number Breakdown

GFixed type
DDistribution application

Applications

1

General power distribution

2

Industrial facilities

3

Commercial buildings

4

Residential complexes

Key Features

  • Fixed construction design
  • Cost-effective solution
  • Reliable performance
  • Simple maintenance

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Rated Voltage0.38
Busbar Rated Current630–3150 A
Short-time Withstand Current30–65 kA
Breaking Capacity30–65 kA
Protection LevelIP30
Enclosure MaterialCold-rolled steel
StandardGB7251, IEC 61439
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)LV Voltage (kV)Current (A)Frequency (Hz)InsulationStandardWeightDimensions
GGD/630GGD0.380.3863050IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/630(60Hz)GGD0.380.3863060IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/1000GGD0.380.38100050IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/1000(60Hz)GGD0.380.38100060IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/1600GGD0.380.38160050IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/1600(60Hz)GGD0.380.38160060IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/2000GGD0.380.38200050IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/2000(60Hz)GGD0.380.38200060IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/2500GGD0.380.38250050IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/2500(60Hz)GGD0.380.38250060IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/3150GGD0.380.38315050IP30GB7251, IEC 61439350 kg800×600×2200 mm
GGD/3150(60Hz)GGD0.380.38315060IP30GB7251, IEC 61439350 kg800×600×2200 mm

Product Drawing

Low Voltage Switchgear - GGD/630

APPEARANCE — DRAWOUT CABINET
BUSWAYDRAWER 1DRAWER 2DRAWER 3DRAWER 4DRAWER 5GGD/630
MAIN CIRCUIT — BUSBAR & FEEDERS
LV SWITCHGEAR — MAIN CIRCUITINCOMINGF1F2F3F4GGD/630
DRAWER CONFIGURATION
DRAWER CONFIGURATIONwithdrawable drawer unitsIncoming1250AFeeder250AFeeder250AFeeder250AGGD/630

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Type

Fixed (hardwired) design - lower cost, but requires de-energizing for major maintenance.

2

Application

General distribution where frequent access is not needed.

3

Standard

Conventional LV distribution cabinet.

- Frequently Asked Questions

What is GGD?

A fixed-type low-voltage distribution cabinet, simpler and lower cost than withdrawable designs.

Fixed vs withdrawable?

GGD is fixed (hardwired), so it is cheaper but requires de-energizing for major maintenance.

Where is GGD used?

General distribution where frequent maintenance access is not required.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: LV assembly — IEC 61439-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.