Outdoor Low-Voltage Switchgear — IP66 Heavy-Duty & Corrosion-Resistant
Outdoor low-voltage switchgear enclosures are engineered for exposed, high-severity corrosive environments: IP66 ingress protection, C5-M corrosion resistance, 316L stainless hardware, and 25 kA short-circuit withstand, with rain hoods and anti-condensation features as standard options. Rated 380 V, IP66 enclosure. Suitable for oil & gas wellheads, coastal and marine installations, chemical plants, and outdoor substations.
Applications
Oil & gas wellhead switch racks
Coastal and marine installations
Chemical and petrochemical plants
Outdoor substations and process facilities
Key Features
- IP66 ingress protection for dust-tight, powerful water-jet resistance in exposed locations
- C5-M corrosion class with 316L stainless steel hardware for high-severity corrosive atmospheres
- 25 kA short-circuit withstand (Icw) for demanding motor and distribution duty
- Rain hood and anti-condensation design to manage weather and internal humidity
- Custom feeder and starter configuration for wellhead and outdoor process applications
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Rated Voltage | 0.4 |
| Busbar Rated Current | 630 A |
| Short-time Withstand Current | 30 kA |
| Breaking Capacity | 30 kA |
| Protection Level | IP30 |
| Enclosure Material | Cold-rolled steel |
| Standard | GB/T 15576, IEC 60439 |
| Compare | Model | Series | Rated voltage (kV) | LV Voltage (kV) | Current (A) | Frequency (Hz) | Insulation | Standard | Weight | Dimensions |
|---|---|---|---|---|---|---|---|---|---|---|
| XLW-63A | Outdoor LV Switchgear | 0.4 | — | — | - | — | GB/T 15576, IEC 60439 | 80 kg | 1090×815×2455 mm | |
| XLW-100A | Outdoor LV Switchgear | 0.4 | — | — | - | — | GB/T 15576, IEC 60439 | 90 kg | 1185×890×2675 mm | |
| XLW-160A | Outdoor LV Switchgear | 0.4 | — | — | - | — | GB/T 15576, IEC 60439 | 104 kg | 1320×990×2970 mm | |
| XLW-250A | Outdoor LV Switchgear | 0.4 | — | — | - | — | GB/T 15576, IEC 60439 | 125 kg | 1485×1115×3345 mm | |
| XLW-400A | Outdoor LV Switchgear | 0.4 | — | — | - | — | GB/T 15576, IEC 60439 | 157 kg | 1715×1285×3865 mm | |
| XLW-630A | Outdoor LV Switchgear | 0.4 | — | — | - | — | GB/T 15576, IEC 60439 | 203 kg | 2015×1510×4540 mm |
Product Drawing
Low Voltage Switchgear - XLW-250A
Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.
Selection Guide
Environment
Specify IP66 + C5-M + 316L hardware for high-severity corrosive or coastal sites.
Protection
IP66 for dust-tight, water-jet resistant outdoor duty.
Short-circuit
25 kA Icw for motor and distribution applications.
- Frequently Asked Questions
What makes the switchgear suitable for outdoor use?
IP66 ingress protection, C5-M corrosion resistance, 316L hardware, rain hoods, and anti-condensation measures allow the enclosure to operate reliably in exposed, corrosive locations.
What is the short-circuit withstand rating?
25 kA Icw is available for motor and distribution duty.
Can the enclosure be customized?
Yes — feeder count, starter type, and form separation can be configured to the application.
What material options are available?
Cold-rolled steel powder-coated as standard, with SS304 and SS316L stainless options for corrosive environments.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(6)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators