QDTB® Transformer

Product Search

Find the right transformer for your needs

Outdoor LV Switchgear Series Low Voltage Switchgear

6 Models available

Outdoor LV Switchgear Low Voltage Switchgear

Images are for illustration purposes only

Outdoor Low-Voltage Switchgear — IP66 Heavy-Duty & Corrosion-Resistant

Outdoor low-voltage switchgear enclosures are engineered for exposed, high-severity corrosive environments: IP66 ingress protection, C5-M corrosion resistance, 316L stainless hardware, and 25 kA short-circuit withstand, with rain hoods and anti-condensation features as standard options. Rated 380 V, IP66 enclosure. Suitable for oil & gas wellheads, coastal and marine installations, chemical plants, and outdoor substations.

Applications

1

Oil & gas wellhead switch racks

2

Coastal and marine installations

3

Chemical and petrochemical plants

4

Outdoor substations and process facilities

Key Features

  • IP66 ingress protection for dust-tight, powerful water-jet resistance in exposed locations
  • C5-M corrosion class with 316L stainless steel hardware for high-severity corrosive atmospheres
  • 25 kA short-circuit withstand (Icw) for demanding motor and distribution duty
  • Rain hood and anti-condensation design to manage weather and internal humidity
  • Custom feeder and starter configuration for wellhead and outdoor process applications

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Rated Voltage0.4
Busbar Rated Current630 A
Short-time Withstand Current30 kA
Breaking Capacity30 kA
Protection LevelIP30
Enclosure MaterialCold-rolled steel
StandardGB/T 15576, IEC 60439
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)LV Voltage (kV)Current (A)Frequency (Hz)InsulationStandardWeightDimensions
XLW-63AOutdoor LV Switchgear0.4——-—GB/T 15576, IEC 6043980 kg1090×815×2455 mm
XLW-100AOutdoor LV Switchgear0.4——-—GB/T 15576, IEC 6043990 kg1185×890×2675 mm
XLW-160AOutdoor LV Switchgear0.4——-—GB/T 15576, IEC 60439104 kg1320×990×2970 mm
XLW-250AOutdoor LV Switchgear0.4——-—GB/T 15576, IEC 60439125 kg1485×1115×3345 mm
XLW-400AOutdoor LV Switchgear0.4——-—GB/T 15576, IEC 60439157 kg1715×1285×3865 mm
XLW-630AOutdoor LV Switchgear0.4——-—GB/T 15576, IEC 60439203 kg2015×1510×4540 mm

Product Drawing

Low Voltage Switchgear - XLW-250A

APPEARANCE — DRAWOUT CABINET
BUSWAYDRAWER 1DRAWER 2DRAWER 3DRAWER 4DRAWER 5XLW-250A
MAIN CIRCUIT — BUSBAR & FEEDERS
LV SWITCHGEAR — MAIN CIRCUITINCOMINGF1F2F3F4XLW-250A
DRAWER CONFIGURATION
DRAWER CONFIGURATIONwithdrawable drawer unitsIncoming1250AFeeder250AFeeder250AFeeder250AXLW-250A

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Environment

Specify IP66 + C5-M + 316L hardware for high-severity corrosive or coastal sites.

2

Protection

IP66 for dust-tight, water-jet resistant outdoor duty.

3

Short-circuit

25 kA Icw for motor and distribution applications.

- Frequently Asked Questions

What makes the switchgear suitable for outdoor use?

IP66 ingress protection, C5-M corrosion resistance, 316L hardware, rain hoods, and anti-condensation measures allow the enclosure to operate reliably in exposed, corrosive locations.

What is the short-circuit withstand rating?

25 kA Icw is available for motor and distribution duty.

Can the enclosure be customized?

Yes — feeder count, starter type, and form separation can be configured to the application.

What material options are available?

Cold-rolled steel powder-coated as standard, with SS304 and SS316L stainless options for corrosive environments.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: LV assembly — IEC 61439-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators