QDTB® Transformer

S20-M-1600/10.5-WT

Renewable Step-Up Transformers Series • 1600kVA • 10.5/35 kV

S20-M-1600/10.5-WT is a 1600 kVA, 10.5/35 kV oil-immersed transformer manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEC 60076, vector group Dyn11, short-circuit impedance 6%, approximate weight 3016 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

S20-M-1600/10.5-WT technical specifications
ModelS20-M-1600/10.5-WT
Rated Capacity1600kVA
HV Voltage10.5 kV
LV Voltage35 kV
Input Voltage0.4-10.5kV step-up
Output Voltage35kV/10kV collector
Frequency50/60 Hz
Vector GroupDyn11
Short-circuit Impedance6%
CoolingONAN
InsulationA (105°C)
Temperature Rise65 K
No-load Loss1640 W
Load Loss14500 W
Efficiency>99%
Weight3016 kg
Dimensions (L x W x H)5940 x 4455 x 6685 mm
Applied StandardIEC 60076

Product Image & Parameters

Renewable Step-Up Transformers - QDTB

Images are for illustration purposes only

S20-M-1600/10.5-WT

Renewable Step-Up Transformers Series

Capacity
1600kVA
Frequency
50/60Hz
Short-circuit impedance
6%
Cooling method
ONAN
Efficiency
>99%
Applied standard
IEC 60076
Connection
Dyn11 (IEC)
Insulation class
A (105°C)
Allowed temperature rise
65K
Energy SavingLow Loss

TECHNICAL DRAWING

Model: S20-M-1600/10.5-WT | Type: Oil-immersed transformer | Capacity: 1600 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.270mm330mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11 (IEC)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level180mm

TOP VIEW

1U1V1W2U2V2W2N180mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section

Technical specifications

1. Model:S20-M-1600/10.5-WT
2. Type:Oil-immersed transformer
3. Capacity:1600 kVA
4. Frequency:50 Hz
5. HV voltage:10.5 kV
6. LV voltage:35 kV
7. HV current:-
8. LV current:-
9. Vector group:Dyn11 (IEC)
10. Impedance:6%
11. Insulation level:A (105°C)
12. Temperature rise:65K
13. No-load loss:1640W
14. Load loss:14500W
15. No-load current:-
16. Cooling method:ONAN
17. Tap changer:±2×2.5% Multi-tap
18. Standard:IEC 60076
19. Dimensions:1800×1200×2200mm
20. Weight:3016kg
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Product Description

S20-M-1600/10.5-WT Renewable Step-Up Transformers New-energy Step-up Transformer (PV/Wind/BESS/EV per selection manual 5), rated 1600kVA, input 0.4-10.5kV step-up, output 35kV/10kV collector, eff >99%, freq 50/60, weight 3016kg, ISO certified China manufacturer

Related Keywords

S20-M-1600/10.5-WTRenewablenew-energy step-up transformer (pv/wind/bess/ev per selection manual 5)1600kVA

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
Class 3 (S13)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

S20-M-1600/10.5-WT - Frequently Asked Questions

QWhat are the main applications of S20-M-1600/10.5-WT?

S20-M-1600/10.5-WT (Renewable Step-Up Transformers series, Oil-Immersed Transformers) is widely used in industrial power distribution, commercial buildings and utility power systems. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of S20-M-1600/10.5-WT?

Key specifications: Capacity: 1600kVA, HV 10.5 kV, LV 35 kV, Frequency 50/60 Hz, Impedance 6%, Connection Dyn11 (IEC), Cooling ONAN, Standard IEC 60076.

QCan S20-M-1600/10.5-WT be custom ordered?

Yes. QDTB® provides comprehensive OEM/ODM customization services. Parameters such as capacity, voltage ratio, cooling method, connection group and protection class can all be adjusted. Over 25 years of manufacturing experience ensures consistent quality.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in S20-M-1600/10.5-WT?

Contact us for pricing, technical support, or custom requirements.