QDTB® Transformer

S-4000/480/240

S Series • 4000kVA • 0.48/0.24 kV

S-4000/480/240 is a 4000 kVA, 0.48/0.24 kV oil-immersed transformer manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with IEEE C57 / ANSI C84.1, vector group Delta-Wye (IEEE Std), short-circuit impedance 7%, approximate weight 7590 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

S-4000/480/240 technical specifications
ModelS-4000/480/240
Rated Capacity4000kVA
HV Voltage0.48 kV
LV Voltage0.24 kV
Frequency60 Hz
Vector GroupDelta-Wye (IEEE Std)
Short-circuit Impedance7%
CoolingONAN
InsulationA (105°C)
Temperature Rise65 K
No-load Loss4764 W
Load Loss31643 W
EfficiencyIEC standard
Weight7590 kg
Dimensions2498×1247×1730 mm
Applied StandardIEEE C57 / ANSI C84.1

Product Image & Parameters

S - QDTB

Images are for illustration purposes only

S-4000/480/240

S Series

Capacity
4000kVA
HV Voltage
0.48kV
LV Voltage
0.24kV
Frequency
60Hz
Short-circuit impedance
7%
Cooling method
ONAN
Efficiency
IEC standard
Applied standard
IEEE C57 / ANSI C84.1
Connection
Delta-Wye (IEEE Std)
Energy SavingLow Loss

TECHNICAL DRAWING

Model: S-4000/480/240 | Type: Oil-immersed transformer | Capacity: 4000 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.330mm390mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDelta-Wye (IEEE Std)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level210mm

TOP VIEW

1U1V1W2U2V2W2N210mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section

Technical specifications

1. Model:S-4000/480/240
2. Type:Oil-immersed transformer
3. Capacity:4000 kVA
4. Frequency:60 Hz
5. HV voltage:0.48 kV
6. LV voltage:0.24 kV
7. HV current:4811.25A
8. LV current:9622.5A
9. Vector group:Delta-Wye (IEEE Std)
10. Impedance:7%
11. Insulation level:A (105°C)
12. Temperature rise:65K
13. No-load loss:4764W
14. Load loss:31643W
15. No-load current:0.2%
16. Cooling method:ONAN
17. Tap changer:±5×2.5% Multi-tap
18. Standard:IEEE C57 / ANSI C84.1
19. Dimensions:2498×1247×1730 mm
20. Weight:7590kg
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Product Description

4000kVA, 3-phase oil-immersed transformer, 60Hz, primary 480V (HV 480V), secondary 240V (LV 240V), IEC, insulation A, impedance 7%

Related Keywords

S-4000/480/240 oil immersed power transformer4000kVA oil type distribution transformer0.48kV distribution network transformerS series general purpose oil filled distribution transformer

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
Class 3 (S13)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

S-4000/480/240 - Frequently Asked Questions

QWhat are the main applications of S-4000/480/240?

S-4000/480/240 (S series, Oil-Immersed Transformers) is widely used in industrial power distribution, commercial buildings and utility power systems. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of S-4000/480/240?

Key specifications: Capacity: 4000kVA, HV 0.48 kV, LV 0.24 kV, Frequency 60 Hz, Impedance 7%, Connection Delta-Wye (IEEE Std), Cooling ONAN, Standard IEEE C57 / ANSI C84.1.

QCan S-4000/480/240 be custom ordered?

Yes. QDTB® provides comprehensive OEM/ODM customization services. Parameters such as capacity, voltage ratio, cooling method, connection group and protection class can all be adjusted. Over 25 years of manufacturing experience ensures consistent quality.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in S-4000/480/240?

Contact us for pricing, technical support, or custom requirements.