Three-Dimensional Wound Core Transformers — S13/S20-M·RL Triangular Core

Three-dimensional wound core (triangular core) oil-immersed transformers use a continuously wound core forming a triangular (delta) magnetic circuit with no air gaps, giving lower no-load loss, lower noise and a more compact, lighter tank than conventional stacked-core designs. Rated 30–2500 kVA in S13/S20-M·RL grades, 6–35 kV primary, built to IEC 60076 for energy-saving distribution applications.

Key Features

  • Triangular (3D) wound core with no air gaps in the magnetic circuit
  • Lower no-load loss and lower noise than stacked-core designs
  • S13 and S20-M·RL loss grades for energy saving
  • Compact and lighter tank, reducing footprint and oil volume
  • 30–2500 kVA, 6–35 kV primary, distribution voltages secondary
  • Built to IEC 60076 distribution transformer requirements

Applications

  • Energy-saving distribution networks
  • Urban and industrial distribution
  • Renewable plant step-up auxiliary supply
  • Green building and low-noise installations

TECHNICAL DRAWING

Model: S13-M.RL-250/10 | Type: Oil-immersed transformer | Capacity: 250 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.180mm240mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11 (IEC)

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level135mm

TOP VIEW

1U1V1W2U2V2W2N135mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity30–1000 kVA
HV Voltage (kV)10
LV Voltage (kV)0.4
Frequency (Hz)50/60
Impedance (%)4, 4.5, 6
CoolingONAN
EfficiencyClass 1
StandardIEC 60076
ConnectionDyn11 (IEC)
Insulation classA (105°C)
Allowed temperature rise65
Noise level≤34 dB(A), ≤35 dB(A), ≤37 dB(A), ≤38 dB(A), ≤39 dB(A), ≤40 dB(A)…
Tap Changer±2×2.5% Multi-tap, ±5×2.5% Multi-tap
No-load loss100–1150 W
Load loss600–10300 W
Select 2-3 models to compare
CompareModelCapacity (kVA)HV Voltage (kV)LV Voltage (kV)WeightDimensions
S13-M.RL-30/1030kVA100.4188 kg1165×860×1415 mm
S13-M.RL-50/1050kVA100.4225 kg1250×920×1510 mm
S13-M.RL-80/1080kVA100.4277 kg1350×995×1635 mm
S13-M.RL-100/10100kVA100.4310 kg1410×1040×1705 mm
S13-M.RL-125/10125kVA100.4350 kg1480×1090×1790 mm
S13-M.RL-160/10160kVA100.4403 kg1565×1155×1895 mm
S13-M.RL-200/10200kVA100.4463 kg1660×1220×2005 mm
S13-M.RL-250/10250kVA100.4534 kg1765×1300×2135 mm
S13-M.RL-315/10315kVA100.4625 kg1890×1390×2285 mm
S13-M.RL-400/10400kVA100.4738 kg2040×1500×2470 mm
S13-M.RL-500/10500kVA100.4868 kg2200×1620×2665 mm
S13-M.RL-630/10630kVA100.41030 kg2395×1765×2900 mm
S13-M.RL-800/10800kVA100.41235 kg2625×1935×3180 mm
S13-M.RL-1000/101000kVA100.41468 kg2875×2115×3480 mm

Selection Guide

1

Loss grade

Choose S13 or S20 (lower loss) per the energy-efficiency target.

2

Noise

Select wound core where low noise is required near buildings.

3

Rating

Size 30–2500 kVA to the distribution load and voltage class.

- Frequently Asked Questions

What is a three-dimensional wound core transformer?

A 3D wound core (triangular core) transformer uses three continuously wound core limbs arranged in a triangle, eliminating the air gaps of stacked cores and reducing no-load loss, noise and size.

What do the S13/S20-M·RL designations mean?

S13 and S20 are Chinese loss grades (S20 is lower-loss); M·RL denotes a three-dimensional wound core oil-immersed distribution transformer.

What are the advantages over stacked core?

Lower no-load losses, lower operating noise, more compact footprint, and less oil volume for the same rating.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(6)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
Class 3 (S13)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

S13 系列(产品库 S13-M / 卷铁芯 S13-M.RL,Class 3)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.