QDTB® Transformer

Product Search

Find the right transformer for your needs

BKDG Series Reactors

21 Models available

BKDG Reactors

Images are for illustration purposes only

BKDG Series - Single-Phase Dry-Type Reactors for Control Circuits

The BKDG series single-phase dry-type reactors are compact components designed for control circuits, signal filtering, and current limiting in low-voltage applications. Features reliable dry-type insulation for maintenance-free operation.

Model Number Breakdown

BReactor (Biyaoqi / Inductor)
KDry-type (Kongqi cooled / Air-cooled)
DSingle-phase (Danxiang)
GGeneral purpose / Control circuit application

Applications

1

PLC control circuit filtering

2

Signal line current limiting

3

Low-voltage power factor correction

4

Control panel noise suppression

Key Features

  • Compact single-phase design for panel integration
  • Dry-type insulation for maintenance-free operation
  • Suitable for control circuit and signal applications
  • Reliable performance in indoor environments

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity1000–100000 kvar
Rated current (A)16.5, 49.49, 82.48, 164.96, 329.91, 494.87…
Rated voltage (kV)35, 110, 220
Frequency (Hz)50
Impedance (%)6
StandardGB10229, IEC 60076-6
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
BKDG-35-1000BKDG1000kVA3516.550665A (105°C)ONANGB10229, IEC 60076-62200 kg900×600×800 mm
BKDG-35-3000BKDG3000kVA3549.4950665A (105°C)ONANGB10229, IEC 60076-65200 kg1200×800×1050 mm
BKDG-35-5000BKDG5000kVA3582.4850665A (105°C)ONANGB10229, IEC 60076-68000 kg1350×900×1200 mm
BKDG-35-10000BKDG10000kVA35164.9650665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-35-20000BKDG20000kVA35329.9150665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-35-30000BKDG30000kVA35494.8750665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-35-50000BKDG50000kVA35824.7950665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-35-60000BKDG60000kVA35989.7450665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-35-100000BKDG100000kVA351649.5750665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-110-5000BKDG5000kVA11026.2450665A (105°C)ONANGB10229, IEC 60076-68000 kg1350×900×1200 mm
BKDG-110-10000BKDG10000kVA11052.4950665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-110-20000BKDG20000kVA110104.9750665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-110-30000BKDG30000kVA110157.4650665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-110-50000BKDG50000kVA110262.4350665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-110-60000BKDG60000kVA110314.9250665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-110-100000BKDG100000kVA110524.8650665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-220-10000BKDG10000kVA22026.2450665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-220-30000BKDG30000kVA22078.7350665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-220-50000BKDG50000kVA220131.2250665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-220-60000BKDG60000kVA220157.4650665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm
BKDG-220-100000BKDG100000kVA220262.4350665A (105°C)ONANGB10229, IEC 60076-614000 kg1600×1000×1500 mm

Product Drawing

Reactor - BKDG-110-30000

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalBKDG-110-30000
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorBKDG-110-30000
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSBKDG-110-30000

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators