BKSC Series - Three-Phase Dry-Type Shunt Reactors for Power Compensation
The BKSC series three-phase dry-type iron-core shunt reactors are designed for MV/HV power systems to compensate capacitive reactive power of long transmission lines. Features dry-type iron-core construction for fire-safe indoor installation with reliable performance.
Model Number Breakdown
Applications
High-voltage transmission line compensation
Urban cable network reactive power management
Power generation plant auxiliary systems
Industrial HV/MV power distribution
Key Features
- Dry-type iron-core construction for fire safety
- Compensates capacitive reactive power in long transmission lines
- Suitable for 6kV to 35kV power systems
- Capacity range from 100kVAR to 5000kVAR
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 100–10000 kvar |
| Rated current (A) | 9.62, 19.25, 28.87, 48.11, 76.98, 96.23… |
| Rated voltage (kV) | 6, 10, 35 |
| Frequency (Hz) | 50 |
| Impedance (%) | 6 |
| Standard | GB10229, IEC 60076-6 |
| Compare | Model | Series | Capacity (kVA) | HV Voltage (kV) | Current (A) | Frequency (Hz) | Reactance | Temp. rise (K) | Insulation | Cooling | Standard | Weight | Dimensions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BKSC-6-100 | BKSC | 100kVA | 6 | 9.62 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 430 kg | 550×370×520 mm | |
| BKSC-6-200 | BKSC | 200kVA | 6 | 19.25 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 720 kg | 630×420×580 mm | |
| BKSC-6-300 | BKSC | 300kVA | 6 | 28.87 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 950 kg | 680×450×620 mm | |
| BKSC-6-500 | BKSC | 500kVA | 6 | 48.11 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 1300 kg | 750×500×680 mm | |
| BKSC-6-800 | BKSC | 800kVA | 6 | 76.98 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 1840 kg | 835×560×760 mm | |
| BKSC-6-1000 | BKSC | 1000kVA | 6 | 96.23 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 2200 kg | 900×600×800 mm | |
| BKSC-6-1500 | BKSC | 1500kVA | 6 | 144.34 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 3000 kg | 1000×650×900 mm | |
| BKSC-6-2000 | BKSC | 2000kVA | 6 | 192.45 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 3800 kg | 1100×700×950 mm | |
| BKSC-6-3000 | BKSC | 3000kVA | 6 | 288.68 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 5200 kg | 1200×800×1050 mm | |
| BKSC-6-5000 | BKSC | 5000kVA | 6 | 481.13 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 8000 kg | 1350×900×1200 mm | |
| BKSC-6-10000 | BKSC | 10000kVA | 6 | 962.25 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 14000 kg | 1600×1000×1500 mm | |
| BKSC-10-100 | BKSC | 100kVA | 10 | 5.77 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 430 kg | 550×370×520 mm | |
| BKSC-10-200 | BKSC | 200kVA | 10 | 11.55 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 720 kg | 630×420×580 mm | |
| BKSC-10-300 | BKSC | 300kVA | 10 | 17.32 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 950 kg | 680×450×620 mm | |
| BKSC-10-500 | BKSC | 500kVA | 10 | 28.87 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 1300 kg | 750×500×680 mm | |
| BKSC-10-800 | BKSC | 800kVA | 10 | 46.19 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 1840 kg | 835×560×760 mm | |
| BKSC-10-1000 | BKSC | 1000kVA | 10 | 57.74 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 2200 kg | 900×600×800 mm | |
| BKSC-10-1500 | BKSC | 1500kVA | 10 | 86.6 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 3000 kg | 1000×650×900 mm | |
| BKSC-10-2000 | BKSC | 2000kVA | 10 | 115.47 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 3800 kg | 1100×700×950 mm | |
| BKSC-10-3000 | BKSC | 3000kVA | 10 | 173.21 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 5200 kg | 1200×800×1050 mm | |
| BKSC-10-5000 | BKSC | 5000kVA | 10 | 288.68 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 8000 kg | 1350×900×1200 mm | |
| BKSC-10-10000 | BKSC | 10000kVA | 10 | 577.35 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 14000 kg | 1600×1000×1500 mm | |
| BKSC-35-500 | BKSC | 500kVA | 35 | 8.25 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 1300 kg | 750×500×680 mm | |
| BKSC-35-1000 | BKSC | 1000kVA | 35 | 16.5 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 2200 kg | 900×600×800 mm | |
| BKSC-35-2000 | BKSC | 2000kVA | 35 | 32.99 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 3800 kg | 1100×700×950 mm | |
| BKSC-35-3000 | BKSC | 3000kVA | 35 | 49.49 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 5200 kg | 1200×800×1050 mm | |
| BKSC-35-5000 | BKSC | 5000kVA | 35 | 82.48 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 8000 kg | 1350×900×1200 mm | |
| BKSC-35-8000 | BKSC | 8000kVA | 35 | 131.97 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 11600 kg | 1500×960×1380 mm | |
| BKSC-35-10000 | BKSC | 10000kVA | 35 | 164.96 | 50 | 6 | 65 | A (105°C) | ONAN | GB10229, IEC 60076-6 | 14000 kg | 1600×1000×1500 mm |
Product Drawing
Reactor - BKSC-6-1500
Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.
Selection Guide
Purpose
Shunt reactor to absorb capacitive reactive power on long lines.
Application
Long transmission lines and cable networks to control voltage rise at light load.
Construction
Dry iron-core construction.
- Frequently Asked Questions
What is a shunt reactor?
A reactor connected in parallel to absorb capacitive reactive power on long lines.
When is BKSC used?
On long transmission lines and cable networks to control voltage rise during light load.
Dry or oil?
BKSC uses dry iron-core construction.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(2)
Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.
X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)
Still required to complete the calculation: inductance L, rated current I, reactive power Q.
L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.
Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.
The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.
Certification
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.