FKSG Series Reactors

8 Models available

FKSG Reactors

Images are for illustration purposes only

FKSG Series - Three-Phase Dry-Type Reactors for Industrial Power Systems

The FKSG series comprises three-phase dry-type reactors engineered for industrial power systems, providing effective current limiting, harmonic suppression and power quality protection. With Class F insulation and maintenance-free dry-type construction, these reactors deliver stable performance in demanding industrial environments.

Model Number Breakdown

FReactance / Filtering type
KReactor
SThree-phase
GDry-type

Applications

1

Industrial power systems

2

Motor drive and soft-start circuits

3

Harmonic filtering

4

Power quality improvement

Key Features

  • Three-phase dry-type construction for industrial duty
  • Class F insulation with low temperature rise
  • Effective current limiting and harmonic suppression
  • Maintenance-free, low-noise operation

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity5–100 kvar
Rated current (A)Custom
Rated voltage (kV)0.69
Frequency (Hz)50/60
Impedance (%)4, 6, 5
StandardGB/T 10228, IEC 60076-6
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
FKSG-100KWFKSG100kVA0.6914450/60465F (155°C)ANGB/T 10228, IEC 60076-6430 kg550×370×520 mm
FKSG-10KWFKSG10kVA0.6914.450/60665F (155°C)ANGB/T 10228, IEC 60076-685 kg380×250×350 mm
FKSG-75KWFKSG75kVA0.6910850/60465F (155°C)ANGB/T 10228, IEC 60076-6360 kg520×350×480 mm
FKSG-15KWFKSG15kVA0.6921.650/60665F (155°C)ANGB/T 10228, IEC 60076-6110 kg400×270×380 mm
FKSG-30KWFKSG30kVA0.6943.250/60565F (155°C)ANGB/T 10228, IEC 60076-6190 kg450×300×420 mm
FKSG-20KWFKSG20kVA0.6928.850/60565F (155°C)ANGB/T 10228, IEC 60076-6140 kg420×280×400 mm
FKSG-5KWFKSG5kVA0.697.250/60665F (155°C)ANGB/T 10228, IEC 60076-655 kg320×220×300 mm
FKSG-50KWFKSG50kVA0.697250/60465F (155°C)ANGB/T 10228, IEC 60076-6270 kg480×320×450 mm

Product Drawing

Reactor - FKSG-30KW

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalFKSG-30KW
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorFKSG-30KW
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSFKSG-30KW

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators