JKSG Series Reactors

8 Models available

JKSG Reactors

Images are for illustration purposes only

JKSG Series - Input Filter Reactors for Capacitor Banks and Drives

The JKSG series offers three-phase dry-type filter reactors for line-side applications, combining harmonic attenuation with inrush current protection. With 5-8% impedance options and Class F insulation, these reactors support stable operation of capacitor banks and drive systems.

Model Number Breakdown

JLine / filter application
KReactor
SThree-phase
GDry-type

Applications

1

Line-side filter circuits

2

Capacitor bank protection

3

Drive and UPS input filtering

4

Power factor and power quality correction

Key Features

  • Line-side harmonic attenuation
  • Inrush current and surge protection
  • 5-8% impedance configuration options
  • Class F insulation, dry-type and maintenance-free

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity5–100 kvar
Rated current (A)12.83, 64.15, 6.42, 128.3, 96.23, 38.49…
Rated voltage (kV)0.45
Frequency (Hz)50/60
Impedance (%)6, 5, 8
StandardGB10229, IEC 60076-6
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
JKSG-10KWJKSG10kVA0.4512.8350/606125H (180°C)ANGB10229, IEC 60076-685 kg380×250×350 mm
JKSG-50KWJKSG50kVA0.4564.1550/605125H (180°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
JKSG-5KWJKSG5kVA0.456.4250/608125H (180°C)ANGB10229, IEC 60076-655 kg320×220×300 mm
JKSG-100KWJKSG100kVA0.45128.350/605125H (180°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
JKSG-75KWJKSG75kVA0.4596.2350/605125H (180°C)ANGB10229, IEC 60076-6360 kg520×350×480 mm
JKSG-30KWJKSG30kVA0.4538.4950/606125H (180°C)ANGB10229, IEC 60076-6190 kg450×300×420 mm
JKSG-20KWJKSG20kVA0.4525.6650/606125H (180°C)ANGB10229, IEC 60076-6140 kg420×280×400 mm
JKSG-15KWJKSG15kVA0.4519.2550/606125H (180°C)ANGB10229, IEC 60076-6110 kg400×270×380 mm

Product Drawing

Reactor - JKSG-30KW

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalJKSG-30KW
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorJKSG-30KW
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSJKSG-30KW

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.