QDTB® Transformer

Product Search

Find the right transformer for your needs

L Series Reactors

8 Models available

L Reactors

Images are for illustration purposes only

L Series - Current-Limiting Reactors for Power System Protection

The L series current-limiting reactors are designed to restrict fault currents in power systems, protecting equipment from short-circuit damage. Compact dry-type construction ensures reliable performance in switchgear and panel installations.

Model Number Breakdown

LReactor / Inductor (Diankangqi)

Applications

1

Switchgear bus fault current limitation

2

Cable network protection

3

Capacitor bank series protection

4

Power system short-circuit management

Key Features

  • Limits short-circuit fault currents to safe levels
  • Compact dry-type construction for indoor use
  • Linear impedance characteristics under fault conditions
  • Compatible with switchgear and panel integration

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity100–2000 kvar
Rated current (A)115.47, 144.34, 173.21, 192.45, 230.94, 288.68
Rated voltage (kV)0.5, 0.8, 1, 1.5, 2, 2.5…
Frequency (Hz)50
Impedance (%)7
StandardGB10229, IEC 60076-6
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
L-100-500L100kVA0.5115.4750765F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
L-200-800L200kVA0.8144.3450765F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
L-300-1000L300kVA1173.2150765F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
L-500-1500L500kVA1.5192.4550765F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
L-800-2000L800kVA2230.9450765F (155°C)ANGB10229, IEC 60076-61840 kg835×560×760 mm
L-1000-2500L1000kVA2.5230.9450765F (155°C)ANGB10229, IEC 60076-62200 kg900×600×800 mm
L-1500-3000L1500kVA3288.6850765F (155°C)ANGB10229, IEC 60076-63000 kg1000×650×900 mm
L-2000-4000L2000kVA4288.6850765F (155°C)ANGB10229, IEC 60076-63800 kg1100×700×950 mm

Product Drawing

Reactor - L-800-2000

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalL-800-2000
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorL-800-2000
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSL-800-2000

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.