QDTB® Transformer

Product Search

Find the right transformer for your needs

QKSC Series Reactors

14 Models available

QKSC Reactors

Images are for illustration purposes only

QKSC Series - Three-Phase Dry-Type Starting Reactors for Motor Control

The QKSC series three-phase dry-type starting reactors are designed for motor starting applications, reducing inrush current during motor startup. Provides smooth acceleration and protects motors and power systems from mechanical and electrical stress.

Model Number Breakdown

QStarting application (Qidong)
KDry-type (Kongqi cooled / Air-cooled)
SThree-phase (Sanxiang)
CIron-core design (Core type)

Applications

1

Large motor soft starting systems

2

Industrial pump and fan motor control

3

Compressor motor starting

4

HVAC system motor protection

Key Features

  • Reduces motor starting inrush current significantly
  • Dry-type iron-core construction for indoor installation
  • Smooth motor acceleration with controlled voltage drop
  • Protects motors from electrical and mechanical stress

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity50–1000 kvar
Rated current (A)4.81, 9.62, 14.43, 19.25, 28.87, 38.49…
Rated voltage (kV)6, 10
Frequency (Hz)50
Impedance (%)6
StandardGB10229, IEC 60076-6
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)Current (A)Frequency (Hz)ReactanceTemp. rise (K)InsulationCoolingStandardWeightDimensions
QKSC-6-50QKSC50kVA64.8150665F (155°C)ANGB10229, IEC 60076-6270 kg480×320×450 mm
QKSC-6-100QKSC100kVA69.6250665F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
QKSC-6-150QKSC150kVA614.4350665F (155°C)ANGB10229, IEC 60076-6580 kg600×400×550 mm
QKSC-6-200QKSC200kVA619.2550665F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
QKSC-6-300QKSC300kVA628.8750665F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
QKSC-6-400QKSC400kVA638.4950665F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
QKSC-6-500QKSC500kVA648.1150665F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
QKSC-10-100QKSC100kVA105.7750665F (155°C)ANGB10229, IEC 60076-6430 kg550×370×520 mm
QKSC-10-200QKSC200kVA1011.5550665F (155°C)ANGB10229, IEC 60076-6720 kg630×420×580 mm
QKSC-10-300QKSC300kVA1017.3250665F (155°C)ANGB10229, IEC 60076-6950 kg680×450×620 mm
QKSC-10-400QKSC400kVA1023.0950665F (155°C)ANGB10229, IEC 60076-61125 kg715×475×650 mm
QKSC-10-500QKSC500kVA1028.8750665F (155°C)ANGB10229, IEC 60076-61300 kg750×500×680 mm
QKSC-10-800QKSC800kVA1046.1950665F (155°C)ANGB10229, IEC 60076-61840 kg835×560×760 mm
QKSC-10-1000QKSC1000kVA1057.7450665F (155°C)ANGB10229, IEC 60076-62200 kg900×600×800 mm

Product Drawing

Reactor - QKSC-10-300

APPEARANCE — AIR-CORE COIL
REACTORinsulator pedestalQKSC-10-300
CONNECTION — SERIES & SHUNT
REACTOR — SERIES & SHUNTSERIES (line)series reactorSHUNT (bus)shunt reactorQKSC-10-300
HARMONIC FILTER — LC BRANCH
DETUNED HARMONIC FILTER (LC)reactorcapacitorBUSQKSC-10-300

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Reactor Inductance ↔ Rating (mH ↔ kvar)

Fill in any two of inductance L, rated current I and reactive power Q — the third is derived. The phase basis (single / three-phase) must be chosen, because the two bases differ by exactly a factor of three.

X = 2πfL · U_L = I·X · Q₁ = I²X (single-phase) · Q₃ = 3I²X (three-phase)

Inputs
Phase basis (required)
Result
Reactance X = 2πfL—
Inductance L—
Rated current I—
Voltage across the reactor U_L = I·X—
Reactive power, single-phase basis: Q₁ = I²X—
Reactive power, three-phase basis: Q₃ = 3I²Xyour basis—

Still required to complete the calculation: inductance L, rated current I, reactive power Q.

Worked example (the customer case)

L = 1 mH, I = 150 A, f = 50 Hz → X = 0.3142 Ω, U_L = 47.12 V, single-phase Q₁ = 7.07 kvar, three-phase Q₃ = 21.21 kvar.

Single-phase and three-phase differ by exactly a factor of three — always state which basis a kvar figure is quoted on.

Insulation level (IEC 60071-1)
Not specified — the factory parameter sheet is required.
Select a rated voltage in the configuration above to see the matching IEC class.
Non-IEC enquiry case:The enquired Um 15 kV / LI 105 kV / AC 52 kV is not an IEC standard combination (no 15 kV and no 105 kV in IEC lists); it belongs to regional systems such as JEC (Japan) / CNS (Taiwan), where a 15 kV class is about LI 95-110 / AC 50-55. Confirm the system before quoting and map to the nearest IEC class (17.5 kV).

The product library (quote-data) carries no per-model inductance or rated current, so no value is auto-filled for a model; the actual figures are confirmed on the factory parameter sheet. An em dash means the value is unavailable — it is never rendered as zero.

Certification
2 · Your price

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.