QDTB® Transformer

RM6-12

RM6 Series •

RM6-12 is a ring main unit manufactured by Shandong Yaqing Electric Power Technology Co., Ltd. (QDTB) in Qingdao, China, designed and tested in accordance with GB3906, IEC 62271-200, approximate weight 700 kg. Available on FOB Qingdao terms; datasheet, routine test report and GA drawing issued with each unit.

Technical Specifications

RM6-12 technical specifications
ModelRM6-12
Rated Capacity
HV Voltage12 kV
Frequency50 Hz
InsulationIP4X
Weight700 kg
Dimensions1000×800×1800 mm
Applied StandardGB3906, IEC 62271-200

Product Image & Parameters

RM6 - QDTB

Images are for illustration purposes only

RM6-12

RM6 Series

HV Voltage
12kV
Frequency
50Hz
Applied standard
GB3906, IEC 62271-200
Insulation class
IP4X
HV side current
630A
Dimensions
1000×800×1800 mm
Weight
700kg
Energy SavingLow Loss

Product Drawing

Ring Main Unit - RM6-12

APPEARANCE — SF6 CABINET
RINGcable compartmentSF6 RMURM6-12
PRIMARY CIRCUIT — RING LOOP
RING MAIN UNIT — PRIMARY CIRCUITINCOMINGINCOMINGLOADRM6-12
RING NETWORK — DUAL SUPPLY
RING NETWORK — DUAL SUPPLYAB1234loadsRM6-12

SPECIFICATIONS

1. Model (Product code):RM6-12
2. Series:RM6
3. Rated voltage:12 kV
4. Rated Current:630 A
5. Max. Fuse Rating:63 A
6. Short-time Withstand Current:20 kA
7. Protection Level:IP54
8. Rated frequency:50 Hz
9. Standard:GB3906, IEC 62271-200
10. Weight:700

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Product Description

RM6-12 SF6 RMU for urban distribution network. Sealed SF6 tank, maintenance-free. Load break switch + fuse or vacuum CB protection modules.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(3)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

RM6-12 - Frequently Asked Questions

QWhat are the main applications of RM6-12?

RM6-12 (RM6 series, Ring Main Units) is widely used in power distribution systems, industrial control and infrastructure projects. Can be flexibly configured according to actual project requirements.

QWhat are the main technical specifications of RM6-12?

Key specifications: Capacity: , Frequency 50 Hz, Standard GB3906, IEC 62271-200.

QHow to get a quote and technical documentation?

Contact via the "Send Inquiry" button below, or contact sales at Alice@qdtb-transformer.com / +86 13698683193. We provide detailed quotations and technical documentation instantly.

Interested in RM6-12?

Contact us for pricing, technical support, or custom requirements.