VCB Ring Main Units — Vacuum Circuit Breaker RMU

VCB ring main units use vacuum circuit breakers for the transformer and feeder protection ways, providing full breaking capacity instead of load-break switching alone. Rated 12–24 kV, 630–1250 A with circuit-breaker protection modules, for distribution networks requiring fault interruption at each way.

Applications

1

Distribution networks with high fault duty

2

Transformer and feeder protection

3

Industrial and data center networks

4

Renewable plant collector feeders

Key Features

  • Vacuum circuit breaker protection modules
  • Full fault-breaking capacity per way
  • 12–24 kV, 630–1250 A
  • Load-break plus breaker protection
  • Relay protection and metering options
  • Compact ring-main configuration

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Rated Voltage12
Rated Current630 A
Max. Fuse Rating63 A
Short-time Withstand Current20 kA
Protection LevelIP4X
StandardGB3906, IEC 62271-200
Select 2-3 models to compare
CompareModelSeriesRated voltage (kV)Current (A)Frequency (Hz)StandardWeightDimensions
VCB-12-630VCB Ring Main Units12630-GB3906, IEC 62271-200131 kg2015×2015×4790 mm
VCB-12-1250VCB Ring Main Units12630-GB3906, IEC 62271-200141 kg2660×2660×6325 mm

Product Drawing

Ring Main Unit - VCB-12-1250

APPEARANCE — SF6 CABINET
RINGcable compartmentSF6 RMUVCB-12-1250
PRIMARY CIRCUIT — RING LOOP
RING MAIN UNIT — PRIMARY CIRCUITINCOMINGINCOMINGLOADVCB-12-1250
RING NETWORK — DUAL SUPPLY
RING NETWORK — DUAL SUPPLYAB1234loadsVCB-12-1250

Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.

Selection Guide

1

Protection

Choose VCB ways where fault interruption and relay protection are required.

2

Rating

Match 630–1250 A and the network fault level.

- Frequently Asked Questions

What is a VCB ring main unit?

A VCB RMU uses vacuum circuit breakers instead of load-break switches, providing full fault-breaking and protection capability at each way.

Load-break vs breaker?

Load-break switches only switch load current; vacuum circuit breakers also interrupt fault currents with relay protection.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(3)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Short-time withstand current: not specified
Peak withstand current: not specified
Switchgear system basis: HV switchgear — IEC 62271-1
Frequency: —
Result
Short-time withstand current Iₖ / I_cw—
Peak withstand current I_p / I_pk—
Peak factor k—
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.