QDTB® Transformer

Product Search

Find the right transformer for your needs

DK Series Single Phase Transformers

15 Models available

DK Single Phase Transformers

Images are for illustration purposes only

DK Series - Single-Phase Control Transformers

The DK series single-phase control transformers provide stable voltage output for industrial control circuits, signal lighting, and auxiliary power supply applications. Compact design with high reliability.

Model Number Breakdown

DSingle-phase
KControl transformer

Key Features

  • Single-phase 220V/380V input
  • Stable output voltage for control circuits
  • Compact and lightweight design
  • High efficiency and low noise

Applications

  • Machine tool control circuits
  • Signal lighting systems
  • Auxiliary power supply
  • Industrial automation

TECHNICAL DRAWING

Model: DK-400VA | Type: Oil-immersed transformer | Capacity: 400 kVA

FRONT ELEVATION

Oil level1U1V2U2NTAPN.P.180mm240mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level135mm

TOP VIEW

1U1V2U2N135mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1NLV TERMINAL BLOCK2U2V2W2N2PETerminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity25–3000 VA
Input voltage≤1000V
Output voltageCustom
Frequency (Hz)50/60
Efficiency≥85%, ≥90%, ≥93%
Allowed temperature rise≤65 K
Short-circuit impedance≤8%
Insulation classClass B (130°C)
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)Input voltageOutput voltageFrequency (Hz)WeightDimensions
DK-25VADK25VA≤1000VCustom50/60110 kg78×84×90 mm
DK-50VADK50VA≤1000VCustom50/60130 kg78×94×90 mm
DK-100VADK100VA≤1000VCustom50/60130 kg112×94×115 mm
DK-150VADK150VA≤1000VCustom50/60130 kg112×102×115 mm
DK-200VADK200VA≤1000VCustom50/60130 kg112×110×115 mm
DK-250VADK250VA≤1000VCustom50/60130 kg112×115×115 mm
DK-300VADK300VA≤1000VCustom50/60130 kg112×120×115 mm
DK-400VADK400VA≤1000VCustom50/60130 kg140×127×140 mm
DK-500VADK500VA≤1000VCustom50/60130 kg140×132×140 mm
DK-700VADK700VA≤1000VCustom50/60130 kg140×137×140 mm
DK-1000VADK1000VA≤1000VCustom50/60130 kg170×170×165 mm
DK-1500VADK1500VA≤1000VCustom50/60130 kg170×180×165 mm
DK-2000VADK2000VA≤1000VCustom50/60130 kg200×185×200 mm
DK-2500VADK2500VA≤1000VCustom50/60130 kg200×195×200 mm
DK-3000VADK3000VA≤1000VCustom50/60130 kg200×205×200 mm

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.