OD Series - Single Phase Transformers

OD isolation transformers provide 1:1 galvanic isolation to protect equipment and personnel. 25-1000 VA, 220 V to 220 V, low leakage current for sensitive loads.

Model Number Breakdown

Key Features

  • Full galvanic isolation between primary and secondary
  • Wide 25-1000 VA range for equipment isolation
  • Low leakage current for sensitive electronics
  • Dry-type construction, safe for indoor use

Applications

  • Industrial power systems
  • Commercial buildings
  • Infrastructure projects

TECHNICAL DRAWING

Model: OD-200VA | Type: Oil-immersed transformer | Capacity: 200 kVA

FRONT ELEVATION

Oil level1U1V2U2NTAPN.P.150mm210mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level120mm

TOP VIEW

1U1V2U2N120mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1NLV TERMINAL BLOCK2U2V2W2N2PETerminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity25–1000 VA
Input voltage220V
Output voltage220V
Frequency (Hz)50/60
Efficiency≥85%, ≥90%, ≥93%
Allowed temperature rise≤65 K
Short-circuit impedance≤8%
Insulation classClass B (130°C)
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)Input voltageOutput voltageFrequency (Hz)WeightDimensions
OD-25VAOD25VA220V220V50/60110 kg73
OD-40VAOD40VA220V220V50/60130 kg90
OD-50VAOD50VA220V220V50/60130 kg90
OD-60VAOD60VA220V220V50/60130 kg90
OD-80VAOD80VA220V220V50/60130 kg90
OD-100VAOD100VA220V220V50/60130 kg105
OD-120VAOD120VA220V220V50/60130 kg108
OD-160VAOD160VA220V220V50/60130 kg110
OD-200VAOD200VA220V220V50/60130 kg112
OD-250VAOD250VA220V220V50/60130 kg115
OD-300VAOD300VA220V220V50/60130 kg122
OD-350VAOD350VA220V220V50/60130 kg125
OD-400VAOD400VA220V220V50/60130 kg130
OD-500VAOD500VA220V220V50/60130 kg133
OD-600VAOD600VA220V220V50/60130 kg135
OD-800VAOD800VA220V220V50/60130 kg155
OD-1000VAOD1000VA220V220V50/60130 kg170

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.