3P-to-1P Series Special/Isolation/Control Transformers

10 Models available

3P-to-1P Special/Isolation/Control Transformers

Images are for illustration purposes only

3P-to-1P Series - Three Phase to Single Phase Conversion Transformers

The 3P-to-1P series phase-converting transformers supply balanced single-phase power from a three-phase source, ideal for feeding single-phase loads from three-phase networks. Dry-type construction with Class F insulation ensures dependable conversion.

Model Number Breakdown

3PThree-phase input
toConversion
1PSingle-phase output

Key Features

  • Converts three-phase to single-phase
  • Balanced single-phase output
  • Class F insulation, dry-type design
  • Suitable for commercial and industrial loads

Applications

  • Single-phase loads on three-phase networks
  • Commercial building supplies
  • Industrial single-phase equipment
  • Balanced load distribution

TECHNICAL DRAWING

Model: 3to1-50KVA | Type: Oil-immersed transformer | Capacity: 50 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.120mm150mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level90mm

TOP VIEW

1U1V1W2U2V2W2N90mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity5–200 kVA
HV Voltage (kV)0.38
LV Voltage (kV)0.38
Frequency (Hz)50/60
Impedance (%)4
CoolingAN
StandardGB/T 1094, IEC 60076
Select 2-3 models to compare
CompareModelSeriesCapacity (kVA)HV Voltage (kV)LV Voltage (kV)Frequency (Hz)ReactanceCoolingStandardWeightDimensions
3to1-15KVA3P-to-1P15kVA0.380.3850/604ANGB/T 1094, IEC 6007675 kg320×270×320 mm
3to1-50KVA3P-to-1P50kVA0.380.3850/604ANGB/T 1094, IEC 60076200 kg450×380×450 mm
3to1-150KVA3P-to-1P150kVA0.380.3850/604ANGB/T 1094, IEC 60076490 kg590×495×590 mm
3to1-75KVA3P-to-1P75kVA0.380.3850/604ANGB/T 1094, IEC 60076280 kg500×420×500 mm
3to1-100KVA3P-to-1P100kVA0.380.3850/604ANGB/T 1094, IEC 60076350 kg550×460×550 mm
3to1-20KVA3P-to-1P20kVA0.380.3850/604ANGB/T 1094, IEC 6007690 kg350×300×350 mm
3to1-10KVA3P-to-1P10kVA0.380.3850/604ANGB/T 1094, IEC 6007655 kg280×240×290 mm
3to1-30KVA3P-to-1P30kVA0.380.3850/604ANGB/T 1094, IEC 60076130 kg400×340×390 mm
3to1-5KVA3P-to-1P5kVA0.380.3850/604ANGB/T 1094, IEC 6007630 kg220×190×230 mm
3to1-200KVA3P-to-1P200kVA0.380.3850/604ANGB/T 1094, IEC 60076620 kg650×540×650 mm

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

特种/隔离/控制变压器(产品库逐型号 noLoadLoss,无独立能效档维度)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.

Related Engineering Calculators

Free sizing and pricing tools for this product category.