QDTB® Transformer

Product Search

Find the right transformer for your needs

SH16 Amorphous Transformers Series Amorphous Alloy Transformers

16 Models available

SH16 Amorphous Transformers Amorphous Alloy Transformers

Images are for illustration purposes only

SH16 Amorphous Transformers — Ultra-Low-Loss Amorphous Core

SH16 series amorphous alloy distribution transformers use amorphous metal cores for ultra-low no-load loss, exceeding SH15/SBH15 energy-saving grades. Rated 30–1600 kVA, 6/10/35 kV primary, oil-immersed, for energy-efficiency programs where minimum no-load loss is the priority.

Key Features

  • Amorphous alloy core with ultra-low no-load loss
  • SH16 energy-saving grade
  • 30–1600 kVA, 6/10/35 kV
  • Oil-immersed sealed-tank construction
  • Lower no-load loss than SH15/SBH15
  • Reduced CO2 and operating cost

Applications

  • Energy-efficiency distribution programs
  • Utility loss-reduction projects
  • Industrial energy-saving retrofits
  • Renewable plant auxiliary supply

TECHNICAL DRAWING

Model: SBH16-M-80/10 | Type: Amorphous alloy transformer | Capacity: 80 kVA

FRONT ELEVATION

Oil level1U1V1W2U2V2W2NTAPN.P.135mm180mm

ELECTRICAL SCHEMATIC

HV WINDING (Delta)1U1V1WLV WINDING (Star)2U2V2W2NDyn11

EFFICIENCY vs LOAD

90%95%98%99%0%25%50%75%100%≈99%load %efficiency %

SIDE VIEW

Oil level105mm

TOP VIEW

1U1V1W2U2V2W2N105mm

TERMINAL BLOCK

HV TERMINAL BLOCK1U1V1W1N1PELV TERMINAL BLOCK2U2V2W2N2PE2122Terminal block configurationTin-plated copper busbar

CORE & WINDING

OIL / TANKHV winding/bushingINSULATIONLV winding/bushingIron coreconcentric cross-section
LEGEND:
Iron core
HV winding/bushing
LV winding/bushing
Dimension line

Specifications Range

All specifications and dimensions can be customized upon request

Model Selector

Key parametersModel Range
Capacity10–400 kVA
HV Voltage (kV)10
LV Voltage (kV)0.4
Frequency (Hz)50/60
Impedance (%)4
CoolingONAN
EfficiencyClass 5, 4
StandardIEC 60076, GB1094, JB/T10318
ConnectionDyn11 (IEC), Dyn11
Insulation classA (105°C), A(105°C)
Allowed temperature rise65
Noise level≤33 dB(A), ≤34 dB(A), 50 dB(A), ≤35 dB(A), 55 dB(A), 58 dB(A)…
Tap Changer±2×2.5% Multi-tap, ±2×2.5% or ±5%
No-load loss-60 W
Load loss390–4520 W
Select 2-3 models to compare
CompareModelCapacity (kVA)HV Voltage (kV)LV Voltage (kV)WeightDimensions
SBH16-M-10/1010kVA100.4169 kg1115×890×1340 mm
SBH16-M-15/1015kVA100.4181 kg1150×920×1380 mm
SBH16-M-20/1020kVA100.4193 kg1175×940×1415 mm
SBH16-M-25/1025kVA100.4204 kg1205×960×1445 mm
SBH16-M-30/1030kVA100.4215 kg1230×980×1475 mm
SBH16-M-40/1040kVA100.4236 kg1275×1020×1530 mm
SBH16-M-50/1050kVA100.4256 kg1315×1050×1575 mm
SBH16-M-63/1063kVA100.4282 kg1365×1090×1635 mm
SBH16-M-80/1080kVA100.4314 kg1420×1135×1705 mm
SBH16-M-100/10100kVA100.4350 kg1485×1185×1780 mm
SBH16-M-125/10125kVA100.4394 kg1555×1245×1870 mm
SBH16-M-160/10160kVA100.4453 kg1650×1320×1980 mm
SBH16-M-200/10200kVA100.4519 kg1745×1395×2095 mm
SBH16-M-250/10250kVA100.4598 kg1855×1485×2230 mm
SBH16-M-315/10315kVA100.4698 kg1990×1590×2385 mm
SBH16-M-400/10400kVA100.4823 kg2145×1715×2575 mm

Selection Guide

1

Loss target

Choose SH16 where the lowest no-load loss is required.

2

Rating

Size 30–1600 kVA to the distribution load.

- Frequently Asked Questions

What is an SH16 amorphous transformer?

SH16 is an ultra-low-loss grade using an amorphous metal core, offering no-load losses lower than SH15/SBH15 for maximum energy saving.

How does amorphous core save energy?

Amorphous metal has much lower hysteresis loss than silicon steel, cutting no-load loss by 60–70%.

Instant Selection & Quote Calculator

Select your specifications to get an estimated price instantly.

1 · Configure
More options(2)
Certification
2 · Your price
Derived Ratings (calculated from the configuration)

The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.

Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ

Inputs taken from the configuration
Capacity: — kVAfrom the configuration above
System voltage: not specified
Impedance voltage uₖ: not specified
Result
Rated current Iₙ—
Short-circuit current I_sc—
Short-circuit current I_sc—
Short-circuit power S_sc—
I_sc is calculated on the transformer impedance basis alone (system impedance neglected) — the same basis used in IEC 60076-5 short-circuit calculations.
System voltage → —

Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.

Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.

Derived losses (from the selected efficiency grade + capacity)
Oil amorphous
No-load loss P0 (kW)—
Load loss Pk (kW)—

Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.

油浸非晶(SBH15-M / SH16)

Reference prices are for estimation only and do not constitute a formal offer.

3 · Get this quote

We will reply with your latest quote instantly.