YB Series - Energy-Saving Prefabricated Substations
The YB series prefabricated substations integrate transformer, HV/LV switchgear into a single compact enclosure. Equipped with S13 energy-efficient transformers for reduced no-load losses, suitable for urban power distribution, industrial parks, and residential areas.
Model Number Breakdown
Applications
Urban residential power distribution
Industrial parks and factories
Commercial building complexes
Temporary construction power supply
Key Features
- Factory-assembled compact design for rapid deployment
- S13 energy-efficient transformer with reduced no-load losses
- Integrated HV/LV switchgear and protection systems
- Suitable for capacities from 100kVA to 800kVA
Specifications Range
All specifications and dimensions can be customized upon request
Model Selector
| Key parameters | Model Range |
|---|---|
| Capacity | 100–2000 kVA |
| HV Voltage (kV) | 12, 20, 35 |
| LV Voltage (kV) | 0.4, 10 |
| Protection Level | IP33 |
| Allowed temperature rise | 65 |
| Standard | GB/T 17467, IEC 61330 |
| Compare | Model | Series | Capacity (kVA) | HV Voltage (kV) | LV Voltage (kV) | Frequency (Hz) | Reactance | Cooling | Standard | Weight | Dimensions |
|---|---|---|---|---|---|---|---|---|---|---|---|
| YB-12/0.4-100 | YB | 100kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 1800 kg | 1500×1200×1800 mm | |
| YB-12/0.4-100-s11 | YB | 100kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 1800 kg | 1500×1200×1800 mm | |
| YB-12/0.4-160 | YB | 160kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2000 kg | 1500×1300×1800 mm | |
| YB-12/0.4-160-s11 | YB | 160kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2000 kg | 1500×1300×1800 mm | |
| YB-12/0.4-200 | YB | 200kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2300 kg | 1700×1350×1900 mm | |
| YB-12/0.4-200-s11 | YB | 200kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2300 kg | 1700×1350×1900 mm | |
| YB-12/0.4-250 | YB | 250kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2500 kg | 1800×1400×2000 mm | |
| YB-12/0.4-250-s11 | YB | 250kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2500 kg | 1800×1400×2000 mm | |
| YB-12/0.4-315 | YB | 315kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3000 kg | 2000×1500×2000 mm | |
| YB-12/0.4-315-s11 | YB | 315kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3000 kg | 2000×1500×2000 mm | |
| YB-12/0.4-400 | YB | 400kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3500 kg | 2200×1500×2200 mm | |
| YB-12/0.4-400-s11 | YB | 400kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3500 kg | 2200×1500×2200 mm | |
| YB-12/0.4-500 | YB | 500kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4000 kg | 2200×1600×2200 mm | |
| YB-12/0.4-500-s11 | YB | 500kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4000 kg | 2200×1600×2200 mm | |
| YB-12/0.4-630 | YB | 630kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4800 kg | 2500×1800×2400 mm | |
| YB-12/0.4-630-s11 | YB | 630kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4800 kg | 2500×1800×2400 mm | |
| YB-12/0.4-800 | YB | 800kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 5500 kg | 2800×2000×2500 mm | |
| YB-12/0.4-800-s11 | YB | 800kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 5500 kg | 2800×2000×2500 mm | |
| YB-12/0.4-1000 | YB | 1000kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 6500 kg | 3000×2200×2500 mm | |
| YB-12/0.4-1000-s11 | YB | 1000kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 6500 kg | 3000×2200×2500 mm | |
| YB-12/0.4-1250 | YB | 1250kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 7500 kg | 3200×2400×2600 mm | |
| YB-12/0.4-1250-s11 | YB | 1250kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 7500 kg | 3200×2400×2600 mm | |
| YB-12/0.4-1600 | YB | 1600kVA | 12 | 0.4 | 50 | 5 | ONAN | GB/T 17467, IEC 61330 | 9000 kg | 3500×2400×2600 mm | |
| YB-12/0.4-1600-s11 | YB | 1600kVA | 12 | 0.4 | 50 | 5 | ONAN | GB/T 17467, IEC 61330 | 9000 kg | 3500×2400×2600 mm | |
| YB-20/0.4-200 | YB | 200kVA | 20 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2300 kg | 1700×1350×1900 mm | |
| YB-20/0.4-315 | YB | 315kVA | 20 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3000 kg | 2000×1500×2000 mm | |
| YB-20/0.4-400 | YB | 400kVA | 20 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3500 kg | 2200×1500×2200 mm | |
| YB-20/0.4-500 | YB | 500kVA | 20 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4000 kg | 2200×1600×2200 mm | |
| YB-20/0.4-630 | YB | 630kVA | 20 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4800 kg | 2500×1800×2400 mm | |
| YB-20/0.4-800 | YB | 800kVA | 20 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 5500 kg | 2800×2000×2500 mm | |
| YBW-12/0.4-200 | YB | 200kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 2300 kg | 1700×1350×1900 mm | |
| YBW-12/0.4-315 | YB | 315kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3000 kg | 2000×1500×2000 mm | |
| YBW-12/0.4-400 | YB | 400kVA | 12 | 0.4 | 50 | 4 | ONAN | GB/T 17467, IEC 61330 | 3500 kg | 2200×1500×2200 mm | |
| YBW-12/0.4-500 | YB | 500kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4000 kg | 2200×1600×2200 mm | |
| YBW-12/0.4-630 | YB | 630kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4800 kg | 2500×1800×2400 mm | |
| YBW-12/0.4-800 | YB | 800kVA | 12 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 5500 kg | 2800×2000×2500 mm | |
| YB-35/400-500 | YB | 500kVA | 35 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4000 kg | 2200×1600×2200 mm | |
| YB-35/10-500 | YB | 500kVA | 35 | 10 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4000 kg | 2200×1600×2200 mm | |
| YB-35/400-630 | YB | 630kVA | 35 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4800 kg | 2500×1800×2400 mm | |
| YB-35/10-630 | YB | 630kVA | 35 | 10 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 4800 kg | 2500×1800×2400 mm | |
| YB-35/400-800 | YB | 800kVA | 35 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 5500 kg | 2800×2000×2500 mm | |
| YB-35/10-800 | YB | 800kVA | 35 | 10 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 5500 kg | 2800×2000×2500 mm | |
| YB-35/400-1000 | YB | 1000kVA | 35 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 6500 kg | 3000×2200×2500 mm | |
| YB-35/10-1000 | YB | 1000kVA | 35 | 10 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 6500 kg | 3000×2200×2500 mm | |
| YB-35/400-1250 | YB | 1250kVA | 35 | 0.4 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 7500 kg | 3200×2400×2600 mm | |
| YB-35/10-1250 | YB | 1250kVA | 35 | 10 | 50 | 4.5 | ONAN | GB/T 17467, IEC 61330 | 7500 kg | 3200×2400×2600 mm | |
| YB-35/10-1600 | YB | 1600kVA | 35 | 10 | 50 | 5 | ONAN | GB/T 17467, IEC 61330 | 9000 kg | 3500×2400×2600 mm | |
| YB-35/10-2000 | YB | 2000kVA | 35 | 10 | 50 | 5 | ONAN | GB/T 17467, IEC 61330 | 10000 kg | 3600×2600×2700 mm |
Product Drawing
Box-Type Substation - YB-12/0.4-630
Note: This is a general product illustration. For detailed technical drawings and specifications, please contact our engineering team.
Selection Guide
Configuration
Select HV switchgear + transformer + LV distribution combination for your application.
Environment
Confirm weatherproofing and ventilation for outdoor use.
Customization
Layout, transformer type and protection can be configured to project needs.
- Frequently Asked Questions
What does a box-type substation contain?
HV switchgear, transformer and LV distribution in a single weatherproof enclosure.
Where are they used?
Urban distribution, industrial parks, renewable plants and temporary power supply.
Can they be customized?
Yes, layout, transformer type and protection can be configured to project requirements.
Instant Selection & Quote Calculator
Select your specifications to get an estimated price instantly.
More options(8)
Certification
The values below are computed from what you selected above. Anything that cannot be computed yet is shown as an em dash — never as zero.
Iₙ = S / (√3·U) · I_sc = 100·Iₙ / uₖ · S_sc = √3·U·I_sc · I_p = k·Iₖ
Still required to complete the calculation: rated capacity S, impedance voltage uₖ, short-time or peak withstand current.
Per-model values (P0 / Pk / uₖ declared by the factory, losses, noise, temperature rise, dimensions, weight) are not in the product library: those rows stay at an em dash until the factory parameter sheet is supplied. An em dash means the value is unavailable — it is never rendered as zero.
Read-only: no price factor, not part of the sum — the loss-grade cost is already carried by the efficiency (subtype) base price, so charging here would double-bill. Values come from the product library type-test data, interpolated between published capacities; grades the library does not cover show an em dash, never zero.
Reference prices are for estimation only and do not constitute a formal offer.
3 · Get this quote
We will reply with your latest quote instantly.
Related Engineering Calculators
Free sizing and pricing tools for this product category.